ZeroScope by vpme.de / av500 – User Manual rev1.0
INSTALLATION
•ZeroScope is a 6 hp Eurorack module
•the modules consumes 30 mA from the 12 V and 10 mA from the -12 V supply,
it does not use the +5 V rail.
•carefully check the orientation of the 16-pin power connector, the red stripe
should be at the bottom of the module, see the labeling on the PCB. There is a
protection diode so plugging it in the wrong way should not do harm.
•DO NOT APPLY INPUT SIGNALS LARGER THAN +10 V/-10 V
•further information and contact details at: http://vpme.de/zeroscope/
BASIC OPERATION
●connect CV or audio signals to the inputs labeled 1, 2 or T:
○1: CH1, channel 1 input
○2: CH2, channel 2 input
○T: EXT, external trigger input
●all input signals are through-connected to the jacks below so you can pass
signals through the scope without a multiple
●inputs 1 and 2 accept signals between -10 V and +10 V, input T is a trigger input
and switches at about +1 V
●rotate the upper knob to change the scope timebase between 10 s/div and
10 μs/div (note that at 10 μs/div only channel 1 is shown, even in Dual mode)
●rotate the lower knob to change the scope gain between 5 V/div to 0.5 V/div
●press the lower knob to toggle the gain setting from CH1 to CH2
●press the upper knob to enter the SETTINGS menu
SETTINGS MENU
In the settings menu, the upper knob selects a setting and the lower knob changes the
value of the selected setting. press the upper knob to leave the SETTINGS menu again
SCOPE MODE
●SINGLE: only CH1 is active and displayed
●DUAL: dual channel mode, CH1 and CH2 are displayed
●X-Y: CH1 drives the X axis and CH2 drives the Y axis
●FREQ: frequency measurement and tuner
TRIGGER MODE
●Trg off: no trigger, scope is free running
●Trg _/: trigger on rising edge of CH1
●Trg \_: trigger on falling edge of CH1
●Ext _/: trigger on rising edge of EXT
●Ext \_: trigger on falling edge of EXT
2