Vutlan VT960i User manual

VT825i & VT825ii / Remote Monitoring Unit
Documentation page: https://vutlan.atlassian.net/wiki/spaces/DEN/pages/2713911301
/VT825i+VT825ii+Data+Center+Monitoring+Unit
Product page: https://vutlan.com/devices/162-55-vt825i-remote-monitoring-unit.html
Brochure: product version 1.2
Function and purpose
The unit is used for environmental monitoring (e.g. temperature, humidity, voltage, leakage, smoke, airflow). It is also used
as an I/O controller (e.g. door control, fans, generator, control panels, UPS, circuit breakers, alarms). Can use up to 1000
different elements - notifications, triggers, timers, logic schemes, sensors, dry contacts. Has built-in Web interface with virtual
sensors, logic schemes, different types of notification, and control panels. Has a slot for an LTE modem for an ethernet
connection reservation.
Two order options:
VT825i has only x1 power inlet.
VT825ii has x2 power inlets, providing a redundant power supply for A&B power distribution.
Order options / Dimensions
System Description
VT825i x1 230V AC power inlet.
VT825ii x2 230V AC power inlets, providing a redundant power supply for A&B power distribution.
VT825iDC x1 230V AC and x1 24-48V DC power inlets.
VT825DC x1 24-48V DC power inlet.
VT825DCDC x2 24-48V DC power inlets.

S
y
st
em
Diagram
V
T8
25i
V
T8
25
ii
V
T8
25
iDC
V
T8
25
DC
V
T8
25
D
C
DC
Physical Description
Front panel:

Back panel:
1. " " - x2 pcs for mounting brackets into a 1U 19" rack slot.1U 19 inch brackets
2. " " - Displays article number of the monitoring unit.Logo sticker
3. " " - A place for a sticker, can be used by a user to place an identifier of the system (for example, an IP Sticker space
address).
4. " .. " - 8 RJ12 analog sensor inputs with auto-sensing. Read instructions at " ",Analog sensors: A1 A8 Analog sensors connection
" ".Sensor configuration
5. " " - Ethernet 10/100 Base-T port, provides an Ethernet connection. Read more in this section "LAN port LAN, GSM, LTE,
".RADIUS, DNS, SSL, VPN
" " - orange LED for Ethernet port. It shows network traffic.Orange LED
" " - green LED for Ethernet port. It shows network traffic. Flashes green when the system starts up. Shows Green LED
the connection state (constant green light - the connection is established, blinking green - the connection attempt).
6. " " - " " can be installed in this slot. Modem slot VT790 / LTE slot modem
Read instructions This modem is ordered separately.
at "VT790 / LTE slot modem", "LAN, GSM, LTE, RADIUS, DNS, SSL, VPN".
7. USB ports are needed for USB camera recording, USB Flash for system logs, and for the system restore. Read instructions
at " ", " ", " ", "Connecting USB camera USB camera settings. How to save a video Saving system logs on USB flash drive USB
".upgrade or restore of default settings
a. " " - type micro USB-port 2.0, required to connect a USB camera.USB 0
b. " " - type USB-port 2.0, required to connect a USB camera or a USB Flash card.USB 1
8. " " - MicroSD card slot with an ejector. The card is needed for data storage or for the "system restore". Read SD card
instructions at " ", " ".Saving system logs to SD card Restore of the appliance (for VT960 series)
9a. " " - digital connector RJ12 for the connection of CAN sensors/extensions/devices on a CAN bus. Modules can CAN DEVICES
be chained together. Read instructions at " ", " ".CAN devises connection Setting up CAN
" " - green LED indicates CAN bus status.LED: CAN
The LED blinks slowly - nothing is connected
The LED blinks fast - configuration is in process
The LED glows constantly - connected to CAN devices
11. " " - accuracy +/- 1 °C.TEMPERATURE SENSOR
12. " " - green LED indicates appliance system status,LED: ACT
- operating mode of the device: switches at a frequency of 2 times per second;
- successful completion of the software update process: switches at a frequency of 4 times per second;
" " - The button can be programmed from the interface for alarm indicating.LED: ALARM
" " - red LED indicates error and traffic.LED: ERR
the operating mode of the device: If everything is normal, the LED is extinguished, if not - there's a constant glow;
software update mode: switches at a rate of 2 times per second;

software update mode: switches at a rate of 2 times per second;
13. " " Dip switch
Normal mode: The switch is switched to the left . The switch should be always in this position.
Recovery mode: The switch is switched to the right . Use this option only in case you need to recover manufacturing
settings.
14a. - 12V 0.25A (for each output) terminals outputs (electronic relay). Read instructions at ""OUTPUTS 12V 0.25A" Connecting
".12V devices to 12V outputs
" " - status indicators for two 12V 0.25A outputs.LEDs: E1, E2
The LED is ON (orange) - the output is ON (the initial state can be configured).
The LED is OFF (orange) - the output is OFF ((the initial state can be configured).
16. " " - Digital inputs (Type IN). Read instructions at " ", "DRY CONTACT INPUTS 1...16 Connecting dry contacts Dry contacts
".settings
19. Please refer to section "Order options" in this document.
18. - Reserve power inlet. 100-240VAC, 50/60Hz, Fuse 2A, Fuse 5x20mm, type C14."RESERVE"
19. " " - Power inlet. 100-240VAC, 50/60Hz, Fuse 2A, Fuse 5x20mm, type C14.MAIN
20. Buttons
9a. " " - the button restarts the appliance. Hold the button for 2 seconds and then let go, the system will restart.Restart
9b. " " - reset smoke sensors. Read more at .Reset settings Operation of smoke detectors in dusty conditions
9b. " " - reset settings to default factory settings.Factory reset
22. " " - optional order option. Only available for custom orders.DC 12V BACKUP POWER
23. " " - Chassis grounding, M4 thread. Enhances the immunity of the equipment against conducted and Chassis grounding
radiated RF disturbances. Please contact a professional electrician before connecting it.
24. " " - optional order option for some of the units. Please refer to section "Order options" in this document.POWER 24-48V DC
24a. - Reserve power inlet. 24-48V DC, 5.08mm 2EDGK power plug, 18-72VDC to 12VDC/0.84A"RESERVE"
24b. " " - Power inlet. 24-48V DC, 5.08mm 2EDGK power plug, 18-72VDC to 12VDC/0.84AMAIN
Connection overview diagram
The front panel of :VT825i & VT825ii

The back panel of :VT825ii
Drawing dimensions

Installing the device into a 19" rack
Use x3 pcs of supplied screws (M3 6mm) for each bracket to fix it on each side of the enclosure as shown in the picture below.
The screws and brackets are supplied with the unit.

Installing LTE slot modem
Product page: https://vutlan.com/modems/155-vt790-lte-slot-modem.html
Datasheet page: https://vutlan.atlassian.net/wiki/spaces/DEN/pages/2309947438/VT790+LTE+modem
Usage
Can be installed in VT855i v1.2, VT855ii v1.2, VT825i v1.2, VT825ii v1.2, VT960i v2, VT960ii v2 monitoring systems. (These
new systems are coming soon).
Description
4G LTE slot modem for Vutlan monitoring units. Allows to receive and send SMS messages. Provides Ethernet over 4G LTE.
Power-cycling is an embedded function.
Panel
VT825i v2.6, VT825ii v2.6, VT855i v2.6, VT855ii v2.6, VT960 v3 use VT740 LTE slot modem.

1.
2.
3.
4.
5.
" " - Connector, used when the modem is installed inside of the appliance to connect LTE auxiliary antenna. The Auxiliary
additional antenna helps to strengthen the signal level. (Auxiliary LTE antenna and antenna output are ordered
separately from the modem).
" " - displays modems status. Blinking = working.Status
"SIM card" - SIM card slot with an injector.
" " - Connector, used when the modem is installed inside of the appliance to connect GNSS antennaantenna
" " - Connector, used when the modem is installed inside of the appliance to connect GSM or LTE main Main antenna
antenna. (The main antenna is supplied together with the modem).
Installation
You can install the modem while the system is turned On. You may wait up to 3 minutes until the Telecom operator
information is renewed.
Step 1 1.1 Unscrew the two screws
holding the front panel called “Mo
”. Keep the screws, you dem slot
will need them in Step 3.
1.2 Take the panel out and put it
away.

Step 2 Plug the modem as shown on the
picture into the opening. The
board should slide into the guide
rails (marked as “1”) and plug
into the jack (marked as “2”).
Step 3 3.1 Use the screws we unscrewed
earlier and screw them in
clockwise, securing the new
modem in place.
3.2 Plug in the SIM card. The SIM
card slot has an injector.
Step 4 4.1 Screw the main LTE antenna
into “ ” jack.Main” antenna
4.2 If you want to strengthen the
signal, you can plug the second
auxiliary antenna into “ ” Auxiliary
jack.
Step 5 You are ready to go! Turn on the
system.
If you want to unmount the modem, you can unscrew the screws and just pull it out using x2 gold-plated antenna jacks.
Configuring the modem
Please read the following section for the configuration instructions:

Online documentation page link: Setting up a modem
The direct page link for users with paper documentation:
https://vutlan.atlassian.net/wiki/spaces/DEN/pages/1016347/Setting+up+a+modem
Inventory
Make sure that the contents of the delivery meet the following configuration. Report a missing or damaged component to your
supplier. If damage occurred during transportation, contact the appropriate delivery service.
Package content Description
Quantity
VT825i VT825ii VT825iDC VT825DC VT825DCDC
1 Monitoring unit VT825i. 1 pc
2 OTG Micro USB cable adater 1 pc
3 RJ-45 3m patch cable.
For LAN Ethernet connection.
1 pc

4 Self-adhesive rubber foot 4 pcs
5 19" rack brackets 2 pcs
6 M3 x 8mm Phillips flat-head screws 6 pcs
7 Configuration manual 1 pc

8 Warranty card 1 pc
9 Terminal plug 3 pins, 3.81 mm.
For 12V relays (E1 & E2).
1 pcs
10 Terminal plug 6 pins, 3.5 mm.
For connecting dry contact inputs.
4 pcs
VT825i VT825ii VT825iDC VT825DC VT825DCDC
11 Terminal plug 2 pins, 5.08mm, 2P.
For power input 24-48VDC.
- - 1 pc 1 pc 2 pc

12 EU Schuko C13 0.75 мм . 230V 10A
2
cable.
1 pc 2 pc 1 pc - -
Technical details
VT325, VT335i, VT336, VT825i, VT825ii, VT855i, VT855ii, VT960i, VT960ii are the monitoring units and can not connect to
each other. For scalability please use extension units and embedded boards. All units except produced in DC / DC version.
● Built-in □ None Extension possible ◊ Not extendable
Versions VT960i / VT960ii
DC/DC; AC/DC
VT855i / VT855ii
DC/DC; AC/DC
VT825i / VT825ii
DC/DC; AC/DC
VT335i VT336 VT325
Device Management: Web, SNMP,
manually via SMS
Yes Yes Yes Yes Yes Yes
Interface VT960i VT855i VT825i VT335i VT336 VT325
LAN: Ethernet 10/100 Mbit Yes Yes Yes Yes Yes Yes
OS: Linux v.5.10 v.5.40 v.5.40 v.5.40 v.3.10 v.3.10
RAM: 1Gb 128Mb 128Mb 64Mb 64Mb 64Mb
CPU speed: 720mHz 600mHz 600mHz 600mHz 300mHz 300mHz
Clock: Built-in clock
Watchdog: Built-in watchdog timer
Yes Yes Yes Yes Yes Yes
Max. amount of sensors: physical
sensors, dry contacts, relays
400 150 150 100 30 6
Max. amount of elements: notificatio
ns, triggers, timers, logic, sensors,
dry contacts, SNMP Get, SNMP Trap,
Dial task and other elements
2000 1000 1000 700 500 500
Protocol support VT960i VT855i VT825i VT335i VT336 VT325
Network protocols: DHCP; HTTP;
HTTPS; DynDNS; SSL/TLS; SNMP
v1, v2c, v3; SMTP; FTP; Syslog;
RADIUS; Modbus RTU; OpenVPN
Yes Yes Yes Yes Yes Yes
VPN: secure data communications;
secure change of connection
between LTE and LAN
Yes Yes Yes Yes Yes Yes
Alerts / Notifications VT960i VT855i VT825i VT335i VT336 VT325
Alert types: E-mail, FTP log, Syslog,
SMTP, SNMP Traps, SMS (Modem is
ordered separately), Web-to-SMS,
Yes Yes Yes Yes Yes Yes

A maximum number of "mail to"
recipients in an E-mail notification:
50 20 20 20 10 10
A maximum number of "SMS to"
recipients in an SMS notification:
also the maximum amount of phone
numbers
50 20 20 20 10 10
Virtual sensors VT960i VT855i VT825i VT335i VT336 VT325
Pings: Built-in function for server
pinging. Test the reach-ability of a
host in a network.
Yes Yes Yes Yes Yes Yes
IP cameras: Connect the IP MJPEG
camera with a proxy via the master
module. Only view, no record.
4 4 4 4 4 4
Get SNMP: Read data from external
equipment via SNMP PDU GET (v1
/2c)
Yes Yes Yes Yes Yes Yes
User keys: Add users who have
access using RFID reader.
Yes Yes Yes Yes Yes Yes
Logic schemes: U sed to specify auto
matic actions to events that occur in
the system.
Yes Yes Yes Yes Yes Yes
Timers: Allows you to plan the
events in the system.
Yes Yes Yes Yes Yes Yes
Triggers: Generate events in the
system if logic is triggered.
Yes Yes Yes Yes Yes Yes
Push notifications Yes Yes Yes Yes Yes Yes
SNMP traps Yes Yes Yes Yes Yes Yes
Virtual Math element (combine
several sensor data and calculate
new data)
Yes Yes Yes Yes Yes Yes
Logic schemes Yes Yes Yes Yes Yes Yes
Modbus TCP/IP: read / write Yes Yes Yes Yes Yes Yes
Power VT960i VT855i VT825i VT335i VT336 VT325
Power input: 90-230V 90-230V 90-230V 12V 12V 12V
Power input DC: 24 48V ÷ 24 48V ÷ 24 48V ÷ 12V □ □
Fuse: Fuse at the inlet 1A 1A 1A 1A □ □
Max. power consumption: 30W 30W 10W 10W 12W 6W
The maximum current load on the
relay:
10А 10А 250mА 250mА 250mА 250mA
Redundant power supply: built-in
voltage monitor, voltage range 9-
12.6V.
Yes
AC/DC
DC/DC
Yes
AC/DC
DC/DC
Yes
AC/DC
DC/DC
Yes
DC 12V
□ □
Outputs VT960i VT855ii VT825i VT335i VT336 VT325
Relay outputs: latching relays
240V*10A
2 2 □ □ □ □
Relays outputs: 12V 0.25A 2 2 2 2 2 2
Max. dry contact outputs (contact
closures/digital outputs)
8 8 □ □ □ □
Audio output: AV OUT 1 □ □ □ □ □

Video output: AV OUT 1 □ □ □ □ □
Inputs VT960i VT855i VT825i VT335i VT336 VT325
Analog port: 6P6C for connection of
any analog sensor.
8 8 8 4 6 2
CAN port: Max number of sensors
Use for connecting CAN-12V-1A
more than 12 devices.
32 32 32 32 20 □
Dry contact inputs: 32 32 16 4 4 2
Modbus: (Max. 32 sensors, Max. line
length 1000m)
1 1 □ □ Yes Through
extension
Reader 1-Wire 1 1 □ □ □ Extension
possible
Video VT960i VT855i VT825i VT335i VT336 VT325
Video cameras: AV, USB, x4 IP USB, x1 IP USB, x1 IP USB, x1 IP USB, x1 IP USB, x1 IP
Video power supply: DC 12V 0,25A
for analog camera
Yes □ □ □ □ □
Other connectors VT960i VT855i VT825i VT335i VT336 VT325
Ethernet port: 10/100Mbit Yes Yes Yes Yes Yes Yes
USB 2.0 Type A 111 □ □ □
USB 2.0 micro 1 1 1 1 1 1
Switch Normal / Recovery: returns
the device to factory settings
□ □ □ □ Yes Yes
FEL button: softly restarts SATA
drive
Yes □ □ □ □ □
Shutdown button: Softly shuts down
the device.
Yes □ □ □ □ □
External Memory VT960i VT855i VT825i VT335i VT336 VT325
SD card slot Yes Yes Yes Yes □ □
SATA Drive: 2.5" HDD or SSD
(ordered separately)
Yes ◊ ◊ ◊ ◊ ◊
Extensions (modules
are ordered separately)
VT960i VT855i VT825i VT335i VT336 VT325
SATA: 2.5" HDD or SSD (ordered
separately)
◊ ◊ ◊ ◊ ◊
Modem (extensions) VT960i VT855i VT825i VT335i VT336 VT325
4G LTE modem: ordered separately. VT790 VT790 VT740 VT740 VT770 □
GSM modem: ordered separately □ □ □ □ □ □
Modem modes:
Gateway: Internet access
Access: Internet access over LTE
SMS: SMS notifications
Gateway /
Access / SMS
Gateway /
Access / SMS
Gateway /
Access / SMS
Gateway /
Access /
SMS
Access /
SMS
SMS
(external
modem)

Embedded sensors VT960i VT855i VT825i VT335i VT336 VT325
Temperature sensor: +/- 1 C Case °
temperature.
Yes Yes Yes Yes Yes Yes
Power supply voltage sensor:
Accuracy (1%)
2 2 2 2 1 1
Environmental
characteristics
VT960i VT855i VT825i VT335i VT336 VT325
Operating temperature: -10 to 80 °C Yes Yes Yes Yes Yes Yes
Storage temperature: –25 to 85 °C Yes Yes Yes Yes Yes Yes
Operating humidity: 0 to 90 %, non-
condensing
Yes Yes Yes Yes Yes Yes
Storage humidity: 0 to 95 %, non-
condensing
Yes Yes Yes Yes Yes Yes
Other Features VT960i VT855i VT825i VT335i VT336 VT325
Installation: 19” 1U 19” 1U 19” 1U Desktop DIN rail Desktop
Dimensions (L x W x H) in mm: 440*44*120 440*44*90 440*44*90 180*35*80 160*90*58 95*35*80
Weight: 2 kg 1,5 kg 1,5 kg 0,7 kg 0,4 kg 0,4 kg
External chassis grounding: M4
thread
Yes Yes Yes Yes □Yes
Web interface (panels) VT960i VT960ii VT855i VT335i VT336 VT325
Dashboard panel: Yes Yes Yes Yes Yes Yes
System tree panel: sensors and
devices displayed in a hierarchy
Yes Yes Yes Yes Yes Yes
Event log panel: 500 logs 300 300 300 200 200
List of latest sent SMS messages: 500 200 200 150 100 100
Supported Vutlan environmental
sensors
Temperature, Outdoor Temperature,
Humidity, Water leakage, Wind
speed meter, Access sensor, Door
sensor, Water Level, AC / DC
current meters, AC voltage monitor,
Smoke detector, Vibration, Motion /
PIR, Converter
Yes Yes Yes Yes Yes Yes
● Built-in □ None Extension possible ◊ Not extendable
Copyright:
Vutlan s.r.o. (LLC)
Remote Infrastructure Monitoring and Control
Other manuals for VT960i
1
This manual suits for next models
9
Table of contents
Other Vutlan Measuring Instrument manuals