it means that the A channel is set to 1 kHz frequency and the B channel is set to 400 Hz
frequency.
OutputLevelandFrequencyAdjust
The output level of the AES signals can be adjusted individually over a range from digital full
scale, 0dBFS, to digital silence, OFF. Incremental adjustment can be made in 1 dB steps in the
range from 0 to 30dBFS and in 10 dB steps in the range from 30 to 60dBFS, Digital silence
(OFF)isthestepbelow60dBFS.
Thefrequencyoftheindividualoutputsmaybesetto100Hz,400Hzor1kHz.
To change the level ensure that you are in the level display mode (for example the readout
displays AES2 A/B 20/10) press the SELECT knob once and the readout will show AES2
A 20dBFS, to change this level rotate the ADJUST knob in either direction to set a new level.
Push the SELECT knob once more for the B channel. If it is desired to change the frequency of
the A or B channel push the ADJUST knob. (Please note that once an individual AES channel
is selected pushing the ADJUST knob toggles between level and frequency) Once all the level
and frequency adjustments are completed push the SELECT knob to return to A/B status
displaywindow.RotatetheSELECTknobtoselectanotherAESoutput.
SelectingtheReferenceInput:
Press the SELECT and ADJUST knobs simultaneously. The readout will display one of the
following:
RefAES,whichmeansthatanexternalAESreferencesignalisselected
RefVideo,whichmeansthatanexternalNTSCvideoblackreferencesignalisselected
RefInt48k,whichmeansthattheinternal48kHzreferenceisselected
RefInt96k,whichmeansthattheinternal96kHzreferenceisselected
To select the appropriate reference signal rotate the ADJUST knob. To exit the reference
selection menu rotate the SELECT knob counterclockwise to display Exit Setup and push
the SELECT knob once. (Note that if the unit will eventually time out and return to the status
displaymodeiftheexitprocedureisnotexecuted)
SettingtheReferenceOutput(AESorWordClock)
Press the SELECT and ADJUST knobs simultaneously. The reference display will appear.
Turn the SELECT knob clockwise and the display will read AES1 AES or AES1 Wrd Clk
indicating whether that output is set to deliver an AES or Word Clock signal. To choose the
appropriate signal rotate the ADJUST knob to toggle between the two types of output signal.
RotatetheSELECTknobtoscrollthroughAESoutputs1to4.
Please note that if an output has been set to deliver a Word Clock signal level and