Warm4Less One-Click User manual

Warm4Less One-Click - RF Wireless
Heating Thermostat User Manual
In the Box:
Thermostat 1pc Screws 2pcs
User Guide 1pc Floor Sensor (3m) 1pc
About Your Warm4less One-Click Thermostat:
•Screen Display: 64mm x 64mm Size: 86mm x
86mm x 23mm
•Colour: White
•Visible wall thickness: 13mm - Non-visible
wall thickness: 86mm/60mm European
•External Sensor option available
•0.5° Accuracy calibration.
•5+2 days programmable (week/weekend) or
manually programmable. 2 pre-set
programmable modes available
•Holiday mode
•Child-Lock function
Product Specification:
•Power: 2 x AA/1.5V Alkaline batteries
•Display accuracy: 0.5°
•Probe Sensor: NTC(10k)1%
•Contact Capacity: 5A/230V (1150W)
•Operating temperature: 0-50°C
•Temperature display range: 0°C-40°C. Range:
5-35°C
•Output: Switch relay
•Insulating condition: Normal
•Running program: 1-week cycle
•Installation: Battery powered
Description:
•Auto mode: Run pre-set program
•Manual mode
•Temporary manual mode
•Holiday mode
•Heating mode –when not present no
heating on
•Clock
•Temperature of external sensor
•Eco-mode
•Comfort-mode
•Programmable mod
•Press power key for 3-4 seconds to lock/unlock
•Advanced options
•programmable mode
3 Programmable Modes:
P1:Run DIY 7 days, 6 periods programmable P2:Run pre-set 7 days, 2 periods programmed
P3:Run preset 5+2 days, 4 periods programmed P1, P2, P3 can be chosen on setting interface
Please note: The time and temperature can’t be adjusted for modes P2 and P3.

Warm4less One-Click Operation:
•Power on: Hold down button for 3 seconds
•Power off: Press rotary button to switch
between and
•Adjust settings: Choose settings option then
click to confirm
•Increase: Clockwise turn
•Decrease: Anti-clockwise turn
•Power key: On the right-hand side
Turning on the One-Click:
Turn the controller on using the power key. Hold down the rotary button for 3 seconds to enter setting adjustment,
and rotate the button to set preferred value, then click to confirm setting.
When the TIME icon is flashing, the user can adjust the set minute, hour and week by using the rotary button.
Warm4less One-Click - Programmable Mode:
3 Different modes: P1, P2 and P3. Hold down the rotary button for 3 seconds, rotate the button to choose P1.
Click the button to select this option and alter the week, temperature and time by rotating and clicking to
confirm each option.
P1: Manually Programmable (Default)
Week
Period
Default Period
Default
Temperature
Day-to-Day
1
0:00-6:00
15℃
2
6:00-9:00
21℃
3
9:00—12:00
15℃
4
12:00—14:00
21℃
5
14:00—17:30
15℃
6
17:30—23:59
21℃
P2: 7 Days Programmable –Day/Night Program
Week
Period
Default Period
Default
Temperature
7 days per week
1
6:00-22:00
21℃
2
22:00-6:00
17℃
P3: 5+2 Days Programmable:
Week
Period
Default Period
Default
Temperature
Workings Days
1
22:00-06:00
17℃
2
06:00-08:00
21℃
3
08:00-16:00
17℃
4
16:00-22:00
21℃
Period
Default Period
Default
Temperature
Weekend
1
06:00-22:00
21℃
2
22:00-06:00
17℃

Holiday Mode: Hold down the rotary button for 3 seconds, select the button to enter holiday mode. Select your
preferred days, and temperature and pressing the rotary button to confirm each selection. The temperature range is
between 5~15
℃
(default 10
℃
). Holiday mode can be cancelled by pressing .
Evening-Saving Mode: Hold down the rotary button for 3 seconds, rotate the button to select the option to enter
the evening-saving mode. Rotate the button to set the preferred temperature (default 17 degrees), press the button
to confirm the selection and when returning to the last interface, it will skip the next setting icon automatically.
Comfort Mode: When entering the mode selection, rotate the dial to choose and press the rotary button to select
comfort mode. The temperature can be adjusted (default 17 degrees) to suit and by pressing the rotary button it will
automatically skip the last interface option .
Receiver Comments:
◼Power light: Green light illuminated
Signal Light: Orange light within 10s after the power comes on (matching IP). The signal light turns off when it matches with the
controller. The orange light will blink within 10s when the power turns off.
◼Fault/load light: Red light
◼IP connection is faulty (IP: FFFF). This red light will blink 2 times (0.25 seconds spacing).
◼This light will blink 3 times when it does not receive wireless signal for 1 hour (0.25 seconds spacing).
This light will blink 4 times when the external sensor is faulty (0.25 seconds spacing).
External sensor temperature alarm for electric/water/underfloor heating:
①The detected temperature by external sensor is above the setting temperature of A5 (Advanced options), this will in turn
then trigger high temperature protection and will flash.
②Detected temperature by external sensor is below setting temperature of A6 (Advanced options). This will then trigger low
temperature protection and appear ,it will auto open relay to heat and the will reappear
Advanced One-Click Options: Hold down the rotary button for 3 seconds, enter the advanced option setting by
rotating the button to advanced , and press the dial.
Symb
ol
Setting item
Setting parameter
Default
A1
Measuring temperature
calibration
-9 -+ 9℃
Accura
cy is
0.5°C
A2
Temperature control
return difference setting
0.5 - 5℃
0.5
A3
Children lock
0: Half lock
1: Full lock
0
A4
Programmable choice
--: Non-programmable
01: Programmable
01
A5
Limit value of high
temperature for external
sensor
--: Cancel high
temperature protection
35°C - 70℃
--
A6
Limit value of low
temperature for external
sensor
--: Cancel low
temperature protection
5℃ - 10℃
5℃
A7
Lowest temperature
limit setting
1- 10℃
5℃
A8
Highest temperature
limit setting
20 - 70℃
35℃
A9
Descaling function
0: Closed
1: Open –(Auto 100 Hrs)
0
AA
Restore factory defaults
Display A 0, press the
rotary button.
Table of contents