User Programming
User Settings Factory Setting Selection
Power Save ON ON/OFF
Detergent Prime OFF ON/OFF
F-Detergent Injection Time 40 0 - 180 secs
W-Detergent Injection Time 15 1 - 30
RInse Aid Prime OFF ON/OFF
W-Rinse Aid Time 12 1 - 30
Display Contrast 27 10 - 40
Power Save function reduces the rinse temperature setting by 10°C when the machine is
idle for 5 minutes or more. The temperature settings return to the set value when door is
opened or START/STOP key is pressed.
Detergent Prime function allows manual operation of the detergent pump to fill the
detergent hose with chemicals. Press UP key to switch the detergent pump on, DOWN key
to switch the pump off. If the detergent pump is turned on and left running, it will stop
automatically after 1 minute of operation.
F-Detergent Time controls the operation time of the detergent pump during the fill of the
wash tank. The factory settings for passthrough models – 80 seconds.
W-Detergent Time sets the injection time of the detergent pump at the beginning of each
wash cycle. Ex-factory setting is 15 seconds as board default.
Rinse Aid Prime function allows manual operation of the rinse aid pump to fill the rinse aid
hose with chemicals. Press UP key to switch the rinse aid pump on, DOWN key to switch
the pump off. If the rinse aid pump is turned on and left running, it will stop automatically
after 1 minute of operation.
W-Rinse Aid Time controls the injection time of the rinse aid peristaltic pump. The rinse aid
pump is set to operate at the beginning of each wash cycle. Ex-factory setting is 12
seconds as board default.
The User Settings menu is accessed by pressing the UP and DOWN keys simultaneously for 5
seconds, the screen should then change to:
Press the POWER button to scroll between settings.
Press the UP and DOWN keys to change a specific setting,
Press the START button to return to the operator screen.
The programming options are specified in the table below:
UP
POWER
DOWN
7 UD - Operator Manual 170323