Start address code
Computer
Light number DMX
192controller
DMX
240controller
DMX
512controller
1 1 1 1
2 17(1+16) 21(1+20) 17(1+16)
3 33(1+16+16) 41(1+20+20) 33(1+16+16)
4 49(1+16+16+16) 61(1+20+20+20) 49(1+16+16+16)
5 65(1+16+16+16+16) 81(1+20+20+20+20) 65(1+16+16+16+16)
…… …… …… ……
N N=192÷16=12 N=240÷20=12 N=512÷16=32
THREE:Instructions of liquid crystal screen
System reset
Standard DMX 512 Address
Address choose condition .press “up”and “down”choose to
Enter.Address 001-511
Pan Inver
.press “up”and “down”choose yes and no to Enter.No
Tilt Inver
.press “up”and “down”choose yes and no to Enter.No
System Reset
.press “up”and “down”choose yes and no to Enter.No
Speed Adjust
Press “up”and “down”choose Track 3 to Enter.X&Y Track 0
FOUR: installation.
1, keep flat or Overhead hook.
2,power connect with the earth safely
3,address setting
4,signal line connection
FIVE :pattern paper
SIX: relevant address code setting of other stage lighting :the switch is set through
1-9.,
Code by binary system. number display board is decided by number.,the
confirmation of the start address code has changes according to the used
controller’s model. the following are a few usual coding ways of several models.
In the table: N represent the most computer controlled by the controller.16,20,60
represent that the channels number of the computer controlled by the controller.
If the serial number of the computer light is 2,and the used controller modal is
DMX-192, according to the following table. the start code is 17,hence the position of
the address is as follows.
17=1+16,to use binary system express is 10001,comply with the front picture.
SEVEN: matters need attention
a) a) there can not be inflammable substance and restricted freight
b)it must has safe line to protect when hang the lamps downward.
b) b) use steady 220V voltage and connect with protection power switch.
c) c) when use the lamps for the second time, the using time can not less than 15
minutes. the lamps can become bright after temperature becoming down.
d) d) Stop use that lamps ,when it does not work in the course of operation. avoid
working for a long time in bad condition.
e) e) Exam the radiating blower regularly .
f) f) When change the lamps, your hand can not touch the glass part of the lamps.
If touch it out of carelessness, please wash your hand with alcohol
a) our of control: 1)exam the signal and connection , short circuit 2)address
code
EIGHT: protection
a) a) exam the lamps and see if the screw is flexible regularly.
b) b) Clear the dusty and garbage regularly.
Nine: trouble clearing
b) lamps off: 1)if power is connecting 2)if the fuse is bad. 3)if the
lamps’ lifespan
If the line become loose. 5) trigger is bad.
Special advice:
Do not removal any part of the lamps in you are not a professional person, please contact
the after sales service department of my company if you need to mend the light
ON
12345678910
1 2 4 8 16 32 64 128 256
TEST