Well SPARKLE User manual

Installation and Operating Manual
Model: SPARKLE
Floodlight with sensor
Thank you for choosing WELL. Please read carefully the following instructions and keep them within reach.

Preorder No.: LEDFN-SPARKLE10BKPIR-WL, LEDFN-SPARKLE20BKPIR-WL, LEDFN-SPARKLE30BKPIR-WL,
LEDFN-SPARKLE50BKPIR-WL
PRODUCT DESCRIPTION
1. Anti-Burst glass cover 5. RA:> 70
2. Die cast aluminium body 6. IP: 44
3. Mounting Brachet 7. Voltage: AC220-240V
4. 15cm cable 8. Ambient Light: 3-2000 LUX
Power
Lumen
Detection
Motion
Speed
Time-Delay
Detection
Range
Detection
Distance
(<24⁰C)
Installatio
n Height
10W
900lm
0.6~1.5m/s
Min. 10sec±3ses
Max 7min±2min
120⁰
(220⁰)
Max 8m
2m-4m
20W
1800lm
0.6~1.5m/s
Min. 10sec±3ses
Max 7min±2min
120⁰
(220⁰)
Max 8m
2m-4m
30W
2700lm
0.6~1.5m/s
Min. 10sec±3ses
Max 7min±2min
120⁰
(220⁰)
Max 8m
2m-4m
50W
4500lm
0.6~1.5m/s
Min. 10sec±3ses
Max 7min±2min
120⁰
(220⁰)
Max 8m
2m-4m
The product adopts good sensitivity detector, integrated circuit. It gathers automatism, convenient
safe, saving-energy and practical functions. It utilizes the infrared energy from human as control-
signal source, it can start the load at once when one enters detection field. It can identify day and
night
automatically. It is easy to install and used widely.
GENERAL
These operating instructions must be read thoroughly as they contain important notes on the safety,
usage and maintenance of your product.
FUNCTION
LUX adjustable: The consumer can adjust work ambient light. It can work in the daytime and at night
when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when
it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the
testingpattern.
Time-delay is added continually: When it receives the second induction signals after the first
induction, it will compute time once more on the rest of the first time-delay basic (set time).
Time-delay adjustment: It can be set according to the consumer’s desire. The
minimum time is 10sec±3sec. The maximum is 7min±2min.

INSTALLATION:
Shut off the power.
Firstly, screw the middle part with the sensor part together, check the right figure, ( this part is
screwed when leaving factory)
Unscrew the beside of the middle part, and install the gimbals’ base in the ceiling or other place
where you want to install, fasten the sensor part (first step in here) with the base,
screw and fix the sensor part to base.
Connect the power and load together according to the following figure.
Switch on the power and test it.
DIAGRAMĂDE CONECTARE
TEST:
After installation, Turned LUX knob clockwise to the maximum (SUN position). Turned time knob anti-
clockwise to the minimum (-).
Turn on the power, the sensor will be electrify and warm-up, 30 sec later, the item will be entered into
working estate.
5~10 seconds after the light goes out for the first time and then sensing, the load should be worked.
Turns LUX knob anti-clockwise to the minimum. If it is tested under the circumstance below 3LUX, load
should not work after induction load stop working; but if you cover the detection window with opaque
objects (towel etc), the load works. Under the condition of no induction signals, the load should stop
working within 5-15 sec.
NOTED: When testing in Daylight, please turn LUX knob to (SUN) position, otherwise, the sensor
will not induce and make the light bright.
NOTE:
Should be installed by electrician or experienced man. Avoid installing it on the unrest objects.
There shouldn’t be hindrance and moving object in front of the detection window effecting detection.
Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.

Considering your safety, please don’t open the cover when you find the hitch after installation.
SOME PROBLEM AND SOLVED WAY:
The load don’t work:
Please check the power and load connect is correct.
Check if the load is good.
Check if the working light corresponds to the ambient light.
The sensitivity is poor:
Please check if there is hinder in front of the detection window to effect receiving the signals.
Please check if the ambient temperature is too high.
Please check if the signals source is in the detection fields.
Please check if the installation height corresponds to the height showed in the instruction.
The sensor can’t shut the load automatically:
Check if there are continual signals in the detection fields.
Check if the time delay is set to the longest.
Check if the power corresponds to the instruction.
Check if the temperature change obviously nears the sensor, such as air condition or central heating etc.
Waste electrical and electronic equipment are a special waste category,
collection, storage, transport, treatment and recycling are important because
they can avoid environmental pollution and are harmful to health. Submitting
waste electrical and electronic equipment to special collection centers makes
the waste to be recycled properly and protecting the environment. Do not forget!
Each electric appliance that arrives at the landfill, the field, pollutes the
environment!