Westinghouse WSHUJ2258C User manual

ANTIMICROBIAL AIR
STERILIZATION HUMIDIFIER /
HUMIDIFICATEUR STÉRILISATEUR
D'AIR ANTIMICROBIEN
Instruction Manual / Manuel d’instructions
WSHUJ2258C
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 1WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 1 22/6/2021 12:25:55 pm22/6/2021 12:25:55 pm

WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 2WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 2 22/6/2021 12:25:55 pm22/6/2021 12:25:55 pm

3
EN
CONTENT
SAFETY INFORMATION
IMPORTANT SAFEGUARDS....................................................................... 4
INSTALLATION LOCATION ........................................................................ 6
POLARIZED PLUG......................................................................................... 7
HOW TO USE
DESCRIPTION OF PARTS ........................................................................... 8
BEFORE FIRST USE ...................................................................................... 10
OPERATING INSTRUCTIONS..................................................................... 13
CLEANING AND CARE ........................................................................ 17
TROUBLESHOOTING ........................................................................... 20
DISPOSAL............................................................................................... 21
INFORMATION AND SERVICE........................................................... 21
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 3WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 3 22/6/2021 12:25:56 pm22/6/2021 12:25:56 pm

4
EN
SAFETY INFORMATION
Read this instruction manual carefully before using the appliance
and keep it for future reference.
1. Use the appliance only for its intended purpose. Improper use
may result in an electric shock, fire or serious injury and may
void the warranty.
2. Before connecting the appliance to the power supply, check
that the voltage indicated on the appliance corresponds with
the voltage in your home. If this is not the case, do not use the
appliance and contact the retail outlet immediately.
3. Only connect the appliance to an earthed wall socket.
4. The power cord has a short design to prevent accidents. Do not
use an extension cord.
5. This appliance is for household use only. It is not suitable for
commercial, industrial or outdoor use.
6. This appliance is intended to be used in households and similar
applications such as:
- sta kitchen areas in shops, oces and other working
environments;
- farm houses;
- by clients in hotels, motels and other residential type
environments;
- bed and breakfast type environments.
7. Ensure the water tank cover and mist nozzle are properly
closed before each use. Do not open the mist nozzle or water
tank cover when the appliance is switched on.
8. Do not move the appliance when it is switched on and / or full
of water.
IMPORTANT SAFEGUARDS
DANGER
DANGER – Immediate hazards
which WILL result in severe
personal injury or death
WARNING
WARNING – Hazards or unsafe
practices which COULD result in
severe personal injury or death
WARNING
When using electrical appliances, basic safety precautions
should always be followed, including the following
CAUTION
CAUTION – Hazards or unsafe
practices which COULD result in
minor personal injury
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 4WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 4 22/6/2021 12:25:56 pm22/6/2021 12:25:56 pm

5
EN
SAFETY INFORMATION
9. Only use the humidifier with the power base supplied.
10. The use of accessories or fittings other than the original parts
supplied with this appliance may result in an injury, fire or
damages and will void the warranty.
11. Only use aromatherapy or essential oil products with this
humidifier.
12. Do not use water that is more than 40°C to fill the water tank
or to clean the appliance.
13. Only use tap water. Do not use distilled water (demineralized
water). Never add any sanitizer to the water.
14. If the appliance gives o an abnormal odor or makes abnormal
sounds, immediately turn it o and unplug it from the power
supply.
15. Do not use the appliance when the water tank is empty.
16. Do not use the appliance in extreme cold temperatures when
the liquid inside may freeze, as this can cause damage to the
appliance. If frozen, wait until the ice has fully melted before
use.
17. Follow the cleaning and maintenance instructions detailed in
the CLEANING AND CARE section of this instruction manual.
18. Do not immerse the appliance or electrical parts of the
appliance in water or any other liquids. Never place them under
running water (see CLEANING AND CARE).
19. To prevent spillages, do not fill the humidifier above its capacity
of 4L.
20. When the water tank is full of water, use two hands to carry the
humidifier to prevent spillage.
21. This appliance can be used by children aged from eight years
and above and by persons with reduced physical, sensory or
mental abilities, or lack of experience or knowledge, if they are
properly supervised or instructed how to use the appliance
in a safe way and understand the hazards involved. Children
should not play with the appliance. Cleaning, maintenance or
connecting the appliance to the power supply should not be
made by children under the age of eight.
22. KEEP OUT OF REACH OF BABIES AND CHILDREN – Keep the
appliance and its cord out of the reach of children younger
than eight years of age.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 5WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 5 22/6/2021 12:25:56 pm22/6/2021 12:25:56 pm

6
EN
SAFETY INFORMATION
23. Children must be supervised to ensure that they do not play
with the appliance.
24. Never leave the appliance unattended while it is switched on.
25. Keep the humidifier and the power cord away from the edge of
tables or countertops and out of the reach of children.
26. DANGER OF ELECTROCUTION! Do not touch or operate the
appliance with wet hands or while standing on a wet floor.
27. Do not connect this appliance to an external timer or remote
control system.
28. To unplug, pull the plug out. Do not pull on the cord.
29. If the power cord or plug is damaged, do not use the appliance.
The power cord must be replaced by the manufacturer, an
authorized service agent or a similarly qualified person.
30. Use only spare parts supplied by the manufacturer or an
authorized service center.
31. Do not under any circumstances attempt to repair the
appliance. For servicing and repairs, contact the retail outlet,
the manufacturer, or an authorized service center.
32. RISK OF SUFFOCATION! KEEP OUT OF REACH OF CHILDREN
– Keep all packaging materials out of the reach of babies and
children.
33. CAUTION! To avoid an electric shock, fire, or injury:
- Make sure the appliance cannot be knocked over or upset and
no water spillage can occur when you are connecting it to the
power supply.
- Keep the humidifier and the power cord away from sharp
edges and the edge of tables or countertops and out of the
reach of children.
- Always unplug the appliance before refilling with water,
overfilling, cleaning, storing and immediately after use.
- Do not let water splash into the electric components inside
the base.
INSTALLATION LOCATION
• Do not place this appliance close to a heat source, such as
astove, to prevent it from being damaged or causing a fire or
injury.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 6WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 6 22/6/2021 12:25:56 pm22/6/2021 12:25:56 pm

7
EN
SAFETY INFORMATION
• Place the appliance at least 20 inches away from the floor or
furniture. Make sure there is at least 50 inches of space above
the appliance and that it is at least 80 inches away from other
household electrical appliances, such as a TV.
• Put the humidifier on a waterproof mat or water-resistant
surface. Do not place it on surfaces that are aected by
moisture, such as wood.
• Always place the appliance on a stable, flat, dry, and heat-
resistant surface.
• Never place the humidifier in a closed room, particularly where
a child or person with reduced physical, sensory, or mental
abilities, or lack of experience or knowledge may be playing,
resting, or sleeping.
• Never allow the power cord to touch any hot surface.
POLARIZED PLUG
The appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
electric shock, this plug is intended to fit into
apolarized outlet only one way. If the plug does
not fit fully into the outlet, reverse the plug. If it
still does not fit, contact a qualified electrician.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR ATTEMPT TO
DEFEAT ITS SAFETY FEATURE IN ANY WAY.
NOTE: Neither Westinghouse nor the dealer can accept any liability
for damage to the product or personal injury resulting from failure
to observe the correct electrical connection procedures.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
HOUSEHOLD USE ONLY
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 7WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 7 22/6/2021 12:25:56 pm22/6/2021 12:25:56 pm

8
EN
HOW TO USE
DESCRIPTION OF PARTS
23
22
21
24
25
26 27 28 29 30
2
1
3
4
6
8
7
15
19
20
17
16
9
10
14
13
11
12
5
18
LED screen icons
Control panel
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 8WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 8 22/6/2021 12:25:57 pm22/6/2021 12:25:57 pm

9
EN
1. Aroma oil tray / air intake
2. Foam filter
3. Aroma oil pad
4. Brush (store on the bottom
of the base)
5. Control panel
6. LED screen
7. Ceramic ball filter
8. Electrolysis sterilization
module
9. Water tank
10. Water tank inlet
11. Mist nozzle
12. Water tank cover
13. Mist condenser stopper
14. Mist condenser
15. Mist tube
16. Air intake
17. Float valve
18. Power cord and plug
19. Base
20. Oscillator (at the bottom of
the recess)
LED screen icons
21. Timer / humidity display
22. Sterilization icon
23. Sleep icon
24. Timer icon
25. Humidity icon
Control panel
26. ON / OFF button
27. MIST button
28. HUMIDITY button
29. STERILIZATION button
30. TIMER button
NOTE: All images shown are for illustrative purposes only and may
not be an exact representation of the product model.
HOW TO USE
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 9WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 9 22/6/2021 12:25:57 pm22/6/2021 12:25:57 pm

10
EN
HOW TO USE
BEFORE FIRST USE
• Remove all packaging from the appliance.
• Unpack all parts and check for damage that may have occurred
during transport. If any parts are damaged or missing, do not
use the appliance and return it to your retail outlet immediately.
MAX
GETTING TO KNOW YOUR HUMIDIFIER
• The humidifier holds 4L of water, which provides 33 to 67 hours
of humidifying action (depending on the mist level you select).
• The electrolysis sterilization module electrolyzes the water into
strong oxidizing ions which can kill airborne viruses, germs and
bacteria*. It is a safe and gentle way to disinfect and sterilize
your environment.
• There are 3 mist levels to select from – high, medium and low.
• You can set the timer to automatically turn o the humidifier
between 1 to 8 hours.
• An aromatherapy oil or essential oil can be used to gently
perfume the room.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 10WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 10 22/6/2021 12:25:57 pm22/6/2021 12:25:57 pm

11
EN
HOW THE STERILIZATION PROCESS WORKS
1. The water (H2O) is pushed up through the electrolysis
sterilization module.
Water Electrolysis
sterilization module
2. Through electrolysis the water is ionized and the chemical
structure of the water is changed into strong oxidizing hydroxyl
radicals (-OH, [O], H+, OH-) that are released into the air via the
mist nozzle. Once released into the air, the strong oxidized ions
breakdown the DNA/RNA of germs, viruses and pathogens
in the air, inhibiting their growth and ability to reproduce.
Killing up to 99.9% of H1N1 & H3N2 Influenza A virus, and
killing over 92% of germs & bacteria including Escherichia coli
& Staphylococcus aureus, leaving your environment virtually
virus, germs and bacteria free.
Cells of viruses, germs and bacteria are
attacked and decomposed
Strong oxidizing
hydroxyl radicals are
formed
Cells of
bacteria are
attacked
Bacteria are
decomposed
Harmless
water and
carbon
dioxide
formed
HOW TO USE
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 11WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 11 22/6/2021 12:25:58 pm22/6/2021 12:25:58 pm

12
EN
SETTING UP THE HUMIDIFIER
1. Lift o and remove the mist nozzle, water tank cover and mist
condenser stopper.
2. Insert the mist condenser into the mist tube making sure the
UP mark is facing upwards.
NOTE: At the base of the mist tube, water pressure is created
by an ultrasonic atomizer that forces the water upwards to the
top of the mist tube. The mist condenser sits at the top of the
water level in the mist tube and its innovative design changes
the pressurized water into the fine mist that is released through
the mist nozzle. For the mist condenser to work properly, it
must be inserted correctly.
3. Fill the water tank with tap water (no warmer than room
temperature). The tank takes approximately 4L of water. Do
not fill with water above the MAX mark on the water tank or on
the water inlet. Make sure you do not pour water over the mist
tube. Pour it in the water inlet area.
NOTE:
Do not add any sanitizer to the water. Only use tap water in this
humidifier. Do not use distilled water.
4. Reassemble the mist condenser stopper, water tank cover and
mist nozzle.
NOTE: Find a location for the humidifier where the bottom and
sides of the appliance are at least 20 inches away from the
floor, walls, bedding, curtains, furniture, and other objects. Also,
make sure that the top of the humidifier is at least 50 inches of
space above the appliance and that it is at least 80 inches away
from other household electrical appliances, such as a TV.
HOW TO USE
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 12WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 12 22/6/2021 12:25:58 pm22/6/2021 12:25:58 pm

13
EN
HOW TO USE
MAX
MAX
MAX
MAX
5. Insert the plug into the mains socket. The humidifier will beep,
the display will flash and then enter standby mode.
OPERATING INSTRUCTIONS
1. Touch the ON / OFF button to turn on the humidifier.
NOTE: The first time you turn on the humidifier, the default
high level mist will turn on and the current room’s humidity
will display. The humidifier will remember the last used
settings when you turn it on again. However, if you unplug the
appliance, it will return to the default settings.
2. Touch the MIST button repeatedly to select one of the mist
settings:
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 13WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 13 22/6/2021 12:25:59 pm22/6/2021 12:25:59 pm

14
EN
HOW TO USE
Display Indicates Meaning
03 High level mist
02 Medium level mist
01 Low level mist
NOTE: When you are in setting mode the display flashes. To
confirm a setting, do not touch any buttons for a few seconds
and the display will stop flashing.
3. Touch the HUMIDITY button repeatedly to select the humidity
level from 40% to 80% in increments of 5%. The humidity
icon displays. The mist will turn on and o as necessary
to maintain the set humidity level. To turn o the humidity
function, touch the humidity button and select --.
4. Touch the STERILIZATION button to turn on the sterilization
function. The sterilization icon displays. The sterilization
function will turn on for 5 minutes every hour until the function
is turned o. Touch the STERILZATION button to turn it o.
5. To set the humidifier to turn o in 1 to 8 hours, touch the TIMER
button repeatedly to select:
0H, 1H, 2H, 3H, 4H, 5H, 6H, 7H or 8H. The timer icon
displays and the screen alternately shows the hours remaining
and the current humidity. To turn o timer function, touch the
Timer button and select 0H.
6. To turn on the sleep function, touch and hold the HUMIDITY
button on the control panel. The sleep icon displays. The
LED screen will turn o. Touch any button to turn o the sleep
function.
7. To redirect the mist, manually rotate the mist nozzle on the top
of the humidifier in any direction (360°).
8. When the water level is low, the unit will beep 3 times and the
display will flash. Make sure you refill the water tank or turn o
the appliance.
NOTE: If the water level is too low for a prolonged period,
the humidifier’s inbuilt protection system will turn o the
humidifier.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 14WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 14 22/6/2021 12:26:00 pm22/6/2021 12:26:00 pm

15
EN
HOW TO USE
9. To turn o the humidifier at any time, touch the ON / OFF
button until the LED screen turns o.
10. Remove the plug from the mains socket to fully turn o the
humidifier.
USING THE AROMA OIL DIFFUSER
IMPORTANT – Always make sure the humidifier is turned o and
empty the tank before adding the aromatherapy or essential oil.
1. Unclip the aroma oil tray on the bottom of the appliance’s base.
If not already installed, insert the foam filter and aroma oil pad
onto the inside of the aroma oil tray.
2. Add the aromatherapy or essential oil until the aroma oil pad is
soaked. If some oil spills outside the aroma oil tray, wipe it up
before proceeding.
3. Put the aroma oil tray back into place and turn on the
humidifier.
NOTE: Do not add the aromatherapy or essential oil directly in
the water tank.
ADDING WATER
There are two ways to add water to the water tank:
• Pour water through the water tank inlet or :
1. Remove the mist nozzle and water tank cover. Then add the
water.
2. When you are facing the control panel, pour the water into the
left-hand side of the humidifier.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 15WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 15 22/6/2021 12:26:00 pm22/6/2021 12:26:00 pm

16
EN
HOW TO USE
3. Make sure you do not fill the water above the MAX mark. If you
put too much water in the water tank, the water will escape via
the overflow hole.
MAX
MAX
MAX
Back
Front
overflow hole
Front
Back
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 16WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 16 22/6/2021 12:26:00 pm22/6/2021 12:26:00 pm

17
EN
CLEANING AND CARE
CAUTION – Always unplug the humidifier from the mains socket
and let it cool down before cleaning.
• Do not immerse the base or power cord in water / liquids or
allow moisture to come into contact with these parts.
• Never use solvents, bacteriostat, chemical or abrasive cleaning
agents, wire brushes, sharp objects or scouring pads to clean
the appliance. Clean the appliance every 2 to 3 days to remove
any film or scale buildup.
• Regular cleaning increases the lifespan of the humidifier.
• Always clean the appliance before storing it for a long time.
• Store the appliance in its original packaging or in a cool, dust-
free, dry environment away from direct sunlight.
CLEANING THE AROMA OIL TRAY AND BASE
1. Remove the aroma oil tray, foam filter and aroma oil pad and
wash in warm soapy water.
2. Use a damp cloth to clean the outside of the base.
3. Reassemble only when all parts are thoroughly dry.
CLEANING THE WATER TANK
1. Remove the mist nozzle and then take o the water tank cover.
2. Pull o the mist condenser stopper. Lift out the mist tube and
slide the mist condenser out of the mist tube.
3. Lift out the ceramic ball filter in the bottom of the water tank.
Remove it and rinse well in water.
MAX
MAX
Oscillator
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 17WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 17 22/6/2021 12:26:01 pm22/6/2021 12:26:01 pm

18
EN
CLEANING AND CARE
4. Use a solution of 1 part vinegar to 3 parts water to clean the
mist nozzle and water tank. Clean the ceramic surface of the
oscillator in the base with a soft toothbrush. Make sure you
remove any scale.
MAX
MAX
Water
(3 Parts)
Distilled
Vinegar
(1 Part)
Alternatively, a citric acid (5-10g in 12 oz water) can be used to
clean these parts. Leave the solution in the water tank for
10-15 minutes.
5. Rinse the items thoroughly. Using a clean cloth, wipe any
deposits and excess water from the parts and dry thoroughly.
6. Reassemble the humidifier.
NOTE: Clean the water tank, water tank cover and mist nozzle
with vinegar or citric acid once a week.
REPLACING THE FILTER
1. Remove the mist nozzle and then take o the water tank cover.
2. Lift the filter out of the water tank.
3. Place the new filter into the bottom of the water tank and then
put the water tank cover and mist nozzle back onto the water
tank.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 18WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 18 22/6/2021 12:26:01 pm22/6/2021 12:26:01 pm

19
EN
CLEANING AND CARE
NOTE: We recommend that you replace the filter every 500 hours
under normal circumstances.
Please visit our web site to purchase your replacement filters for
the Westinghouse Antimicrobial Air Sterilization Humidifier.
Replacement Filter model number: WAHUF010X4
Web Site: https://shop.corehpi.com/
For all inquiries, comments or questions regarding the
Westinghouse Antimicrobial Air Sterilization Humidifier,
Please contact our customer service:
westinghouse@westinghousehomeware.com
Canada Customer Service: 1-888-692-1033
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 19WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 19 22/6/2021 12:26:02 pm22/6/2021 12:26:02 pm

20
EN
TROUBLESHOOTING
Problem Possible Cause Solution
The
appliance
will not turn
on.
The power cord or
plug is loose or not
connected.
Check the power cord and
plug. Make sure they are
firmly connected to the
base and mains socket,
respectively.
The
appliance is
not working.
• There is not
enough water in
the water tank.
• The appliance is
tilting.
• The appliance is
not producing
enough mist.
There is a
buildup of dust
or scale.
• Refill the water tank.
• Place the appliance on a
stable, even surface.
• Touch the MIST button
to increase the mist
level.
• Clean the mist nozzle,
mist condenser stopper,
mist condenser and mist
tube as well as the water
tank (see CLEANING
AND CARE).
• Check the mist
condenser is correctly
installed.
• Check the float valve
and / or oscillator in
the base is working
and not damaged.
Clean if necessary (see
CLEANING AND CARE).
If damaged, take the
appliance to a qualified
service provider for
repair.
The mist has
an odor.
The appliance may
be dirty.
• Clean the water tank
and its parts (see
CLEANING AND CARE).
• Replace the old water in
the tank with fresh tap
water.
WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 20WSHUJ2258C_AIR STERILIZATION_CA_2L_V2.indd 20 22/6/2021 12:26:02 pm22/6/2021 12:26:02 pm
Table of contents
Languages:
Other Westinghouse Humidifier manuals
Popular Humidifier manuals by other brands

Vicks
Vicks Embrace VUL900 Series owner's manual

Condair
Condair HumiLife RH Series installation manual

HoMedics
HoMedics TOTAL COMFORT UHE-WM350 Instruction manual and warranty information

Kenmore
Kenmore Sears 758.144530 owner's manual

Vitek
Vitek VT-8557 Manual instruction

Kenmore
Kenmore Kenmore 758.144532 owner's manual