F?;.Electricai requirements
WARNING:
DO NOT PLUG THE “PIGTAIL”
POWER CORD INTO A LIVE WALL
RECEPTACLE BEFORE CORD IS
PERMANENTLY CONNECTED TO THE
TERMINAL BLOCK.
1
2.
3.
4.
5.
6.
This:
appliance ml st be connected to the proper
electrical voltage and frequency as specified on
nameplate. A separate 40 ampere circuit is required.
Fuse both sides of the line. DO NOT fuse the neutral.
A time-delay fuse or circuit breaker is recommended.
Wire sizes must conform to the requirements of the
National Electrical Code ANSVNFPA 70-l 984 and/or
local codes and ordinances. The nameplate is
located on the front frame of the oven behind the
300:.
All wires endtng at he appliance must terminate tn
ring type terminals
All power cords arld cables to appliance must be
Vted with a UL aporoved strain relief.
Tne range should ne connected with copper wire
Inly. Aluminum wire requires special connectors.
mproper use may create a fire hazard.
4pplrance may be :onnected directly to the fused
jrsconnect (or circuit breaker) box through flexible
armored or non-metallic sheathed copper cable. Do
lot use an extension cord. Allow 4 feet (min.) slack
50appliance can be moved for servicing. Wire sizes
nust conform to the ampere rating of the range. See
laragraph B-l abcve.
JVARNING: THE rERMlNAL BLOCK ON THE
APPLIANCE ACCEPTS COPPER WIRE ONLY,
‘JOT ALUMINUM. IF ALUMINUM HOUSE WIRING
vlUST BE CONNECTED, USE ONE OF THE
-0LLOWING PROCEDURES :
* Connect copper wire to the range terminal block
(use ring terminals).
81Connect the copper wire to the aluminum house
wrring using special connectors UL listed and
designed for joining copper to aluminum.
1~Wire size and connectors must conform to
the ampere rating of the range as stated in
paragraph B-l.
Attach special ring connectors to the aluminum
house wiring that are UL listed and designed for
joining copper to aluminum. These special ring
connectors (available at electrical supply houses)
can be attached directly to the range terminal
block.
The connectors must conform to the ampere
rating of the range as stated in paragraph B-1.
7. If local codes permit, your range may be connected
with a three wire flexible type, UL listed “pigtail”
power cord of the proper ampere rating.* Plug must
match a 3-wire NEMA type lo-50R receptacle
(shown below).
8. CAUTION: FOR MOBILE HOME USE, A 4-WIRE
POWER CORD MUST BE USED. This appliance is
manufactured with ground connected to frame. This
must be revised so green ground wire of 4-wire
power cord is connected to frame.
If using a 4-wire NEMA type 14-50R receptacle
(shown above) you must use a matching 4-wire UL
listed “pigtail” power cord. Cord should be type SRD
or SRDT, at least 4 feet long with all conductors
ending in ring terminals at the appliance.
MINIMUM CONDUCTOR
SIZE.
(4-WIRE COPPER POWER CORD)
For 40 ampere circuits: two No. 8 conductors, one
No. 10 white neutral, and one No. 8 green ground.
‘CAUTION: Power Cord Requirements-Only a power
supply cord kit rated at 240 volts, 50 amperes and in-
vestigated for use with ranges shall be used.
3