Electricalconnection
Electrical Shock Hazard
Electrical ground is required on this
appliance.
Do Not connect to the electrical supply until
the appliance ispermanently grounded.
Disconnectthe powerto the junction box
before makingthe electrical connection.
This appliance must beconnected to a
grounded, metallic, permanent wiring system
or a grounding connector should be
connected tothe grounding terminal or wire
lead on the appliance.
Failureto do so could result in death or
serious injury.
brass
terminal nuts
terminal
block terminal
block cover
Remove the terminal block cover located
• on the back of range.
Depending on your electrical supply,
•make the three-wire or four-wire
connection following the "Power supply cord
method" or "Direct wire method" instructions.
This appliance ismanufactured with the neutral
terminal connected tothe cabinet. Use a three-
wire, U.L.-listed, 40-ampere power supply cord
(pigtail);or if local codes Do Not permit
grounding through the neutral, use a four-wire
power supply cordrated at 250 volts, 40-amperes
and investigatedfor use with ranges. (See "Four-
wire electrical connection.")
knockout knock out
opening for .opening for
40-ampere power
power supply cable
supply cord
1. Disconnectthe power supply.
2. Remove the knockoutfor the 40-ampere
power supply cord.
3. Assemble a U.L.-listedstrain relief in the
opening.
4. Insertthe power supplycord through the
strain relief, allowing enough slackto easily
attachthe wiring to theterminal block.
5. Useonly ring-typeterminals to connect the
power supply.To securethe power supply
cord, usethe 3/8" brass nutsattached to the
terminal blockcover. Be sure nuts are installed
tight.
6. Complete electricalconnection accordingto
your type electricalsupply ("Three-wire
electricalconnection" or "Four-wire electrical
connection.")
Three-wire electrical connection:
silver-colored
screw
I
grounding Neutral
link (center wire)
line 1
U.L-listed strain relief
and 40 ampere range
power supply cord
Figure3
Usethis method ONLY iflocal codesPERMIT
connecting cabinet-grounding conductorto neutral
wire of power supply cord.
7. Use the brassterminal nuts attachedto the
terminal blockcover to connect the neutral wire
(centerwire) to the silver-coloredterminal screw
on theterminal block.See Figure3.
8. Connectthe other two wires to outer terminal
screwson the terminal block.See Figure 3.
9. Do Not loosen factory-installed nuts alreadyon
the terminal. Tighten nuts with 3/8" nut driver
for proper electricalconnection.
10.Tighten the strain reliefscrews.
11. Reinstallthe terminal block cover.
12. Plugpower supply cord into grounded electrical
outlet.
Four-wire electrical connection:
grounding
Figure4
irounding-link
screw
green
grounding
wire _o nd_e_-
SFigure5
silver-colored
tblrcmkn:¢lre_
green . I
grounding _
neutral wire
ter wire)
ed strain relief
mpere range
power supply cord
Figure6
Usethis method for mobile homes andwhenever
four-wire installation is required.
7. Remove the grounding-link screw from the
range frame. Save the grounding-link screw.
Bend up the grounding link so that it does not
contact the range. See Figure 4.
8. Connect the green grounding wire from power
supply cord to the range using the grounding-link
screw. The groundingwire must be attachedfirst
and must not contact any otherterminal. See
Figure5.
9. Connectthe neutral (center wire) wire to the
center, silver-coloredterminal screw on the
terminal blockusingthe brassnutsthat are
attachedto the terminal blockcover. See
Figure6.
10.Connect the othertwo wires to the outer
terminals on the terminal block.See Figure6.
11.Do Not loosenthe factory installed nuts already
on the terminal. Tighten nuts with 3/8" nut driver
for proper electricalconnection.
12.Tighten the strain relief screws.
13.Replacethe terminal blockcover.
14.Plug power supply cord into grounded electrical
outlet.
This appliancemay be connected directly to the fuse
disconnect or circuit breaker box; or with a U.L.-listed,
40-ampere rangepower supply cord (pigtail). Depending
on your electrical supply, make the required three-wire or
four-wire connection.
1.Disconnectthe power supply.
2. Remove the knock-outfor the
power supply cable.
3. Assemble aU.L.-listedconduit
connector in the power supply cable
opening.
4.Strip outer covering back3 inches
from end, exposing the wires.
Stripthe insulation back 1 inch
from the end ofthe each wire.
5.Form the bare wire into a "U"
shaped hook.
6.Insert the power supply cable
through the conduit connector,
allowing enough slack to easily attach the wiring
terminal block.
7. Complete electrical connection according to your type
electrical supply ("Three-wire electrical connection" or
"Four-wire electrical connection.")
U.L.-listed conduit
connoctor,_
Three-wire electrical connection:
silver-colored
terminal block
screw
grounding
link (white wire)
line
U.L.-listed conduit connector
Figure 7 and power supply cable.
Usethis method ONLY if localcodes PERMIT
connecting cabinet-grounding conductor to neutral
wire of power supply cable.
8. Usethe brassterminal nutsattached to the
terminal blockcover to connect the neutral wire
(white wire) to the silver-colored terminal screw on
the terminal block.See Figure7.
9. Connect the other two wires to outer terminal
screwson the terminal block. See Figure 7.
10.Do Not loosen factory-installed nuts already on
the terminal. Tighten nuts with 3/8" nut driver for
proper electrical connection.
11.Tighten the locking ring and clamping screws of
the conduit connector.
12.Reinstall the terminal block cover.
Four-wire electrical connection:
Figure 8 grounding-
grounding link _link screw
bare wire
from _J_l_=RiJi_;_ _L1grounding-linkscrew
power " -- I
su.p.p,y I silver-colored
CaDle I _X_(_//i//_ I terminal block screw
Figure 9 ___L__-_ neutral.
I- w.irr:,(wh'te
bare wire from _._//_,_,... I
powersuppIy-/ I"_j..k.x_/,,1J_ I
cable rIi__ I
I_U.L. listed conduit
connector and
Figure 10 power supply
cable
Usethis method for mobile homes and whenever
four-wire installation is required.
8. Remove the grounding-link screw from the range
frame. Save the grounding-link screw. Bend up the
grounding link so that it does not contact the range.
See Figure 8.
9. Connect the bare grounding wire from power
supply cable to the range using the grounding-link
screw. The grounding wire must be attached first
and must not contact any other terminal. See
Figure9.
10.Connectthe neutral (white wire) wire to the
center,silver-colored terminal screw on the terminal
blockusing the brass nutsthat are attached to the
terminal blockcover. See Figure 10.
11.Connectthe other two wires to the outer
terminals on the terminal block. See Figure 10.
12.Do NOT loosenthe factory installed nuts already
on the terminal. Tighten nuts with 3/8" nut driverfor
proper electricalconnection.
13.Tighten the locking ring and clamping screws of
the conduitconnector.
14. Replacetheterminal blockcover.
Page3