Whirlpool UXD8630DY Parts list manual

A
.Downdraft vent
B. Cooktop
C. Measurement of cooktop rear
overhang.
D. D = Measurement of cooktop rear
overhang (C) + 1¹³⁄₁₆" [46.2 mm] (E)
E. 1¹³⁄₁₆" (46.2 mm)
F. ½" (12.7 mm) minimum
G. ¼" (6.4 mm) minimum
H. Countertop and backsplash
I. ½" (12.7 mm) minimum
A
BC
E
H
D
I
G
F
30" (76.2 cm) and 36" (91.4 cm) Retractable (Pop-Up) Downdraft Vent System
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice. Ref. W10342491C
2/8/2012
Page 1 of 3
COUNTERTOP CUTOUT DIMENSIONS
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
UXD8630DY UXD8636DY
Electrical
A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is required.
Top trim widths:
30" (76.2 cm)
36" (91.4 cm)
13¹⁄₂" (34.3 cm)
retractable
vent height
27" (68.6 cm) for 30" (76.2 cm) vent
33" (83.8 cm) for 36" (91.4 cm) vent
16¹⁄₂" (42.0 cm)
10"
(25.4 cm)
2¹⁄₈" (5.4 cm)
28¹⁄₂"
(72.4 cm)
³⁄₈" (0.95 cm)
1¹⁄₂" (3.8 cm)
13¹⁄₈" (33.4 cm)
5¹⁄₄"(13.3 cm)
for 30" (76.2 cm) vent
8¹⁄₄"(21.0 cm)
for 36" (91.4 cm) vent
³⁄₄
(1.9 cm)
LOCATION REQUIREMENTS
NOTE: Downdraft vent is installed directly behind the cooktop. Install the
downdraft vent first, then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
● Have a qualified technician install the downdraft vent. It is the installer’s
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located on the front of
the downdraft vent above the terminal box cover.
● Downdraft vent location should be away from strong draft areas, such as
windows, doors, and strong heating vents or fans.
● Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance.
● Consult the cooktop manufacturer installation instructions before making any
cutouts.
Check that the downdraft vent and cooktop location will clear the
cabinet walls, backsplash, and rear wall studs inside the cabinet.
Check for the minimum distance between the front edge of the
countertop and the front edge of the cooktop. The minimum horizontal
distance between the overhead cabinets is the same as the width of the
installed downdraft vent.
● All openings in ceiling and wall where the downdraft vent will be installed must
be sealed.
● Grounded electrical outlet is required. See “Electrical Requirements” section.
● When installing the downdraft vent, the cabinet drawer will need to be removed
and the drawer front installed permanently to the cabinet.
Cabinet Construction:
Downdraft vent is designed for use in a cabinet with a depth of 24" (61 cm).
Some installations require a countertop deeper than 25" (63.5 cm). See the
Countertop Cutout Dimensions section.
The maximum depth of the overhead cabinet is 13" (33 cm). Overhead cabinets
installed at either side of the downdraft vent must be 18" (45.7 cm) above the
cooking surface.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or
when such standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
A= ¹⁄₂" (12.7 mm)
minimum
21⁵⁄₁₆"
(54.1 cm)
Cutouts are
for 3¹⁄₄" x 10"
(8.3 x 25.4 cm)
rectangular or 6"
(15.2 cm) round
vent system. Centerline of cooktop cutout
21⁵⁄₁₆"
(54.1 cm)
Locate power
supply junction
box at lower
left hand
rear corner
of the cabinet.
10" (25.4 cm)
NOTES:
● See cooktop manufacturer’s instructions for cooktop cutout depth and width.
● Use dimensions for vent system cutout location that applies to your
installation.
● Interior mounted blower systems connect with 3¹⁄₄" x 10" (8.3 x 25.4 cm)
rectangular or 6" (15.2 cm) round vent system. The cutout locations for this
vent system will depend on your specific installation.
CABINET DIMENSIONS
IMPORTANT: Countertops with a bull-nosed front edge are not
recommended for these installations.
● Some models require a countertop deeper than 25" (63.5 cm); see
the following Countertop Cutout Dimensions section.
● To avoid mistakes, it is recommended that the cooktop and vent
cutouts be drawn on the countertop before making any cutouts.
● See Cooktop Installation Instructions for complete cutout
dimensions, location dimensions and installation details.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice. Ref. W10342491C
2/8/2012
Page 2 of 3
VENTING METHODS - INTERIOR MOUNTED VENT MOTOR ONLY
Determine which venting method is best for your application. Vent system
can terminate through either the wall or floor.
Island location
Front (standard) mounted
blower motor
Rear mounted blower
motor
A. Down vent
A
A
NOTE: For island locations, the blower motor can be mounted for right,
left, or rear venting if needed for your application. Most island applications
would still require the venting to be directed down through the floor.
A. Down vent
B. Left vent
C. Ri
g
ht vent
BC
A
Island Location
Vent system installed under a concrete slab using PVC sewer
pipe.
Front (Standard) Mounted Blower Motor
A
B
C
D
E
F
G
H
I
J
K
L
M
A. ½" (12.7 mm) minimum to
backsplash or rear wall
B. ³⁄₄" (19.1 mm) maximum
backsplash depth
C. 27¹⁄₂" (69.9 cm) on 30" (76.2 cm)
models
33¹⁄₂" (85.9 cm) on 36" (91.4 cm)
models
D. D = Measurement of cooktop rear
overhang + 1¹³⁄₁₆" (46.2 mm)
A
B
C
D
IMPORTANT: Make sure there is proper clearance within the wall or floor
before making exhaust vent cutouts.
● Use heavy (rigid) metal vent.
● Venting system must terminate to the outside.
● Do not terminate the vent system in an attic or other enclosed area.
● Do not use 4" (10.2 cm) laundry-type wall caps.
● Do not install 2 elbows together.
● Do not use plastic or metal foil vent.
● The length of vent system and number of elbows should be kept to a
minimum to provide efficient performance.
● Use no more than three 90°elbows
● Make sure there is a minimum of 24" (61 cm) of straight vent between
the elbows if more than one elbow is used.
● Use clamps or duct tape to seal all joints in the vent system.
● Use caulking tape to seal the exterior wall or floor opening around cap.
● Do not cut joist or stud. If vent cutout falls over a joist or stud, a
supporting frame must be constructed.
Flexible metal vent is not recommended. If it is used, calculate each foot of
flexible vent as 2 ft (0.6 m) of rigid metal vent.
Flexible elbows count twice as much as standard elbows.
Recommended Vent System Length:
For either interior-mounted or exterior-mounted blower installations, the
vent system length should not exceed the maximum lengths listed in the
Maximum Length of Vent System chart. See “Calculating Vent System
Length”in the “Venting Methods”section in the Installation Instructions.
Cold Weather Installations
An additional back draft damper should be installed to minimize backward
cold air flow and a thermal break should be installed to minimize
conduction of outside temperatures as part of the vent system. The
damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters
the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems when
using ventilation systems greater than specified CFM of air movement. The
specified CFM varies from locale to locale. Consult your HVAC professional
for specific requirements in your area.
VENTING REQUIREMENTS
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice. Ref. W10342491C
2/8/2012
Page 3 of 3
Vent Piece 6" (15.2 cm) Round
45°elbow 2.5 ft
(0.8 m)
90°elbow 5.0 ft
(1.5 m)
6" (15.2 cm) 0.0 ft
wall cap (0.0 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) transition (1.4 m)
6" (15.2 cm) to 3¹⁄₄" x 10" 1 ft
(8.3 cm x 25.4 cm) transition (0.3 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
to 6" (15.2 cm) 90°elbow (1.5 m)
transition
6" (15.2 cm) to 3¹⁄₄" x 10" 5.0 ft
(8.3 cm x 25.4 cm) 90°elbow (1.5 m)
transition
Example vent system
The following example falls within the maximum vent length of 35 ft
(8.9 m).
2 - 90°elbow = 10.0 ft (3 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Transition = 4.5 ft (1.4 cm)
Length of 6" (15.2 cm) or = 22.5 ft (6.8 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
system
A. Blower motor
B. Transition
C. 90°elbows
D. 6" back draft damper (supplied)
AB
C
6 ft
(1.8 m)
2 ft (0.6 m)
D
Vent 3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
Rectangular
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
90°elbow (1.5 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 12.0 ft
flat elbow (3.7 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 0.0 ft
wall cap (0.0 m)
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Calculating Vent System Length
3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent is required from the blower
motor box. It can be transitioned to 6" (15.2 cm) round vent if needed.
Maximum Length of Vent System
Vent Length
6" (15.2 cm) round 35 ft (8.9 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 35 ft (8.9 m)
Rear Mounted Blower Motor
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent transition with damper (supplied)
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90°PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 6" (15.2 cm) round 90°PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum
A
B
C
D
E
F
G
H
I
J
K
L
M

This manual suits for next models

1

Other Whirlpool Ventilation Hood manuals

Whirlpool HHPN 6.4F AM X User manual

Whirlpool

Whirlpool HHPN 6.4F AM X User manual

Whirlpool AKR 758 UK IXL Operating instructions

Whirlpool

Whirlpool AKR 758 UK IXL Operating instructions

Whirlpool Custom Series User manual

Whirlpool

Whirlpool Custom Series User manual

Whirlpool RH2030XJB2 User manual

Whirlpool

Whirlpool RH2030XJB2 User manual

Whirlpool KPEC992MSS User manual

Whirlpool

Whirlpool KPEC992MSS User manual

Whirlpool AKR 799 IX AKR 799 IX Quick start guide

Whirlpool

Whirlpool AKR 799 IX AKR 799 IX Quick start guide

Whirlpool Maytag WVU37UC0F User manual

Whirlpool

Whirlpool Maytag WVU37UC0F User manual

Whirlpool RHH 4300 SERIES User manual

Whirlpool

Whirlpool RHH 4300 SERIES User manual

Whirlpool UXW6530BSS0 Product information sheet

Whirlpool

Whirlpool UXW6530BSS0 Product information sheet

Whirlpool UXI6536BS0 User manual

Whirlpool

Whirlpool UXI6536BS0 User manual

Whirlpool AKR 504 IX/1 User manual

Whirlpool

Whirlpool AKR 504 IX/1 User manual

Whirlpool 30" WALL-MOUNT CANOPY RANGEHOOD Product information sheet

Whirlpool

Whirlpool 30" WALL-MOUNT CANOPY RANGEHOOD Product information sheet

Whirlpool Build-in 30 inch Product information sheet

Whirlpool

Whirlpool Build-in 30 inch Product information sheet

Whirlpool RH2300 SERIES User manual

Whirlpool

Whirlpool RH2300 SERIES User manual

Whirlpool UXT2030AYB0 Product information sheet

Whirlpool

Whirlpool UXT2030AYB0 Product information sheet

Whirlpool WVW51UC0HV0 User manual

Whirlpool

Whirlpool WVW51UC0HV0 User manual

Whirlpool AKR290/WH User manual

Whirlpool

Whirlpool AKR290/WH User manual

Whirlpool WVW75UC6DS0 Product information sheet

Whirlpool

Whirlpool WVW75UC6DS0 Product information sheet

Whirlpool UXT4236ADS User manual

Whirlpool

Whirlpool UXT4236ADS User manual

Whirlpool W10018010 Product information sheet

Whirlpool

Whirlpool W10018010 Product information sheet

Whirlpool GZ7736XGS1 User manual

Whirlpool

Whirlpool GZ7736XGS1 User manual

Whirlpool GZ7736XGS User instructions

Whirlpool

Whirlpool GZ7736XGS User instructions

Whirlpool WVU57UC6 Product information sheet

Whirlpool

Whirlpool WVU57UC6 Product information sheet

Whirlpool AKR 468 IX User manual

Whirlpool

Whirlpool AKR 468 IX User manual

Popular Ventilation Hood manuals by other brands

Reversomatic 4000-250ES2 Installation and operating instructions

Reversomatic

Reversomatic 4000-250ES2 Installation and operating instructions

AEG DM 8600 OPERATING AND INSTALLATION Manual

AEG

AEG DM 8600 OPERATING AND INSTALLATION Manual

Pando E-250 installation guide

Pando

Pando E-250 installation guide

LG DC9121GAU instruction manual

LG

LG DC9121GAU instruction manual

GE JV367HWW Owners and installation manual

GE

GE JV367HWW Owners and installation manual

Siemens iQ300 LI97SA530B Instructions for installation and use

Siemens

Siemens iQ300 LI97SA530B Instructions for installation and use

Electrolux IH EFC 9780 Installation, use and maintenance manual

Electrolux

Electrolux IH EFC 9780 Installation, use and maintenance manual

LuxeAir PINAR134SS Installation instruction guide

LuxeAir

LuxeAir PINAR134SS Installation instruction guide

Kuppersbusch DEL5100.0 Instructions for use

Kuppersbusch

Kuppersbusch DEL5100.0 Instructions for use

NuTone SM6500 instruction manual

NuTone

NuTone SM6500 instruction manual

ElectrIQ eiQCHB60B Installation and user manual

ElectrIQ

ElectrIQ eiQCHB60B Installation and user manual

GE JV394SBB Installation information

GE

GE JV394SBB Installation information

Bosch dhdrm36uc installation instructions

Bosch

Bosch dhdrm36uc installation instructions

La Germania KV90LAG1NB installation manual

La Germania

La Germania KV90LAG1NB installation manual

ELICA ASTI EAS428S2 Use, care and installation guide

ELICA

ELICA ASTI EAS428S2 Use, care and installation guide

Venmar HEPA 3100 Installation and user guide

Venmar

Venmar HEPA 3100 Installation and user guide

Westinghouse WRI520GA user manual

Westinghouse

Westinghouse WRI520GA user manual

IKEA LUFTBUREN manual

IKEA

IKEA LUFTBUREN manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.