manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Winegard
  6. •
  7. Rack & Stand
  8. •
  9. Winegard DS2000S User manual

Winegard DS2000S User manual

Other Winegard Rack & Stand manuals

Winegard MT-SM10 User manual

Winegard

Winegard MT-SM10 User manual

Winegard RK-2000 User manual

Winegard

Winegard RK-2000 User manual

Winegard DS-3000 User manual

Winegard

Winegard DS-3000 User manual

Winegard DS-2000 User manual

Winegard

Winegard DS-2000 User manual

Winegard MT-SM40 User manual

Winegard

Winegard MT-SM40 User manual

Winegard RK-4000 User manual

Winegard

Winegard RK-4000 User manual

Winegard MT-SM30 User manual

Winegard

Winegard MT-SM30 User manual

Winegard MT-SM10 User manual

Winegard

Winegard MT-SM10 User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

c
lag holes
(5/16"x 3" lag screw
recommended)
stud
If siding is heavy enough, the
outer holes can also be used
to help secure the base.
a
b
Universal Mount w Adapter Plate DS2000S Quick Start Guide
INSTALLATION
Printed in U.S.A. © 2022 Winegard Company
Rev 9-22 2452507
Starlink is a trademark of Space Exploration Technologies Corp. All trademarks, registered trademarks and logos
are the property of their respective owners and are not aliated with Winegard Company.
1LOCATE a stud in the area to be
installed.
2DRILL a small pilot hole to help start
threading the lag bolts (5/16"x 3"
recommended) (a).
3APPLY silicone sealant to the back of
the base to seal holes (b).
4USE the lag bolts to tighten the base to
the wall. Make sure the mast is plumb.
5INSERT the U-bolts through the slots
in the adapter plate and secure loosely
with the nuts (c).
6POSITION the adapter plate facing
UP, and place the bottom U-bolt over
the antenna mount pipe (c). Tighten
the two bottom U-bolt nuts.
7SLIDE the auxiliary pipe through the
upper U-bolt and into the antenna mount
pipe as far as possible (d). The second
guide rests on the top edge of the pipe
mount. Tighten the nuts on the upper
U-bolt until the pole is secure. Verify the
bottom U-bolt is also secure.
WARNING:
INSTALLATION OF THIS PRODUCT
NEAR POWER LINES IS DANGEROUS. For
your safety, follow the installation instructions.
See back for grounding instructions
1.0"– 1.5"
auxiliary
pipe dia.
or Starlink
CONTENTS:
2 - U-bolts
1 - Adapter plate
4 - Flanged hex nuts
1 - Pipe & foot assembly
d
Not provided: 7/16"wrench, lag bolts
SCAN
FOR
WARRANTY
OR CALL
800-288-8094
Winegard Company 2736 Mt. Pleasant St. |Burlington, IA 52601
MORE
PRODUCT
INFORMATION
HOW TO PROVIDE LIGHTNING PROTECTION
FOR TV ANTENNA AND SET
STEP 1. Mount the lightning arrestor as close as possible
to where the downlead enters the house.
STEP 2. The ground wires for both the mast and the
downlead should be copper or aluminum wire,
number eight (8) or larger.
STEP 3. The downlead wire from the antenna to the
lightning arrestor should be secured every
four (4) to six (6) feet to prevent whipping.
NOTE: In the case of a "ground up" antenna installation,
it may not be necessary to ground the mast if the
mast extends four or more feet into the ground.
Consult a TV serviceman for proper depth in your
location.
HOW TO PROVIDE LIGHTNING
PROTECTION
FOR TV ANTENNA AND SET
STEP 1. Mount the lightning arrestor as close
as possible to where the downlead enters the
house.
STEP 2. The ground wires for both the mast
and the downlead should be copper or
aluminum wire, number eight (8) or larger.
STEP 3. The downlead wire from the antenna
to the lightning arrestor should be secured
every four (4) to six (6) feet to prevent
whipping.
NOTE: In the case of a "ground up" antenna
installation, it may not be necessary to ground
the mast if the mast extends four or more feet
into the ground. Consult a TV serviceman for
proper depth in your location.
1450071
Antenna Lead
In Wire
Ground
Clamp
Electric
Service
Equipment
Antenna
Discharge Unit
(NEC Section 810-20)
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
Ground
Clamps
Grounding Conductors
(NEC Section 810-21)
NEC - National Electrical Code
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Antenna
Lead-in Wire
Ground
Clamp
Ground
Clamp
Electric
Service
Equipment
Grounding Conductors
(NEC Section 810-21)
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
Antenna Discharge Unit
(NEC Section 810-20)
NEC - National Electrical Code
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70