manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wolf
  6. •
  7. Burner
  8. •
  9. Wolf SRT484DG Instructions for use

Wolf SRT484DG Instructions for use

Planning Information
48" (1219) Sealed Burner Rangetops
MODELS SRT486C / SRT486G / SRT484CG / SRT484DG / SRT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
5/06
1
There's a good reason why professional chefs choose
gas cooking; control. The patented, dual-stacked sealed
gas burners of our new sealed burner rangetop take
control to a new level. Two levels, really. The upper-tier
burner delivers maximum heat transfer at higher settings;
the lower-tier continuous flame ably handles the
subtleties of simmering and melting.
Patented features along with the Wolf exclusive infrared
charbroiler, infrared griddle and French Top ensure this
rangetop stands out from the rest in performance and
also beauty.
Let Wolf, the corporate companion and kitchen soul mate
of Sub-Zero, fuel your passion for cooking and kitchen
design.
Continuous,
cast iron top grates
Dual-stacked,
sealed burners
Stainless steel
exterior finish
Infrared griddle
(optional)
Infrared charbroiler
(optional)
Low-profile
island trim
Location of rating
plate
Griddle indicator
light
Control knobs with
platinum bezels
Model SRT484CG shown
The Wolf 48" (1219) sealed burner
rangetop is available in natural or LP gas,
with your choice of several top configura-
tions. Model numbers indicate the
rangetop features; (C) charbroiler, (G)
griddle, (DG) double griddle and (F) French
top. The model number followed by (-LP)
denotes an LP gas model.
This appliance is certified by Star-K
to meet strict religious regulations in
conjunction with specific instructions
found on www.star-k.org.
Model SRT486C
Model SRT486G
Model SRT484CG
Model SRT484DG
Model SRT484F
Planning Information
48" (1219) Sealed Burner Rangetops
MODELS SRT486C / SRT486G / SRT484CG / SRT484DG / SRT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
Dimensions may vary by ±
1
/
8
" (3).
2
FEATURES
Natural or LP gas models
Classic stainless steel exterior finish with
island trim
Distinctive red or black control knobs
Platinum bezels surround all knobs—chrome
or brass bezels optional
Porcelain-coated cast iron continuous top
grates
Optional infrared charbroiler, infrared griddle,
double griddle and French top configurations
Dual-stacked, sealed surface burners, all
with simmer capabilities and automatic
reignition at all settings
15,000 Btu/hr (4.4 kW) burners with
950 Btu/hr (.3 kW) delivered at simmer
9,200 Btu/hr (2.7 kW) burner with
325 Btu/hr (.1 kW) delivered at simmer
and melt feature
Certified by Star-K to meet religious
regulations
CSA certified for US and Canada
Two and five year residential warranty—
exclusions apply; warranty information can
be found on our website, wolfappliance.com
477/8" (1216)
OVERALL WIDTH
241/4"
(616)
121/2"
(318)
WITH 5"
RISER
171/2"
(445)
WITH 10"
RISER
271/2"
(699)
WITH 20"
RISER
281/2" (724)
OVERALL DEPTH
81/2" (216)
OVERALL
HEIGHT
COOKING
SURFACE
71/2"
(191)
91/4"
(235)
OVERALL DIMENSIONS
Planning Information
48" (1219) Sealed Burner Rangetops
MODELS SRT486C / SRT486G / SRT484CG / SRT484DG / SRT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
SPECIFICATIONS
Overall Rangetop Width 47 7/8" (1216)
Overall Rangetop Height
(to cooking surface) 81/2" (216)
Overall Rangetop Depth 281/2" (724)
Dual-Stacked Sealed Surface Burners
15,000 Btu/hr (4.4 kW) burners with 950 Btu/hr
(.3 kW) delivered at simmer
Single 9,200 Btu/hr (2.7 kW) burner with 325 Btu/hr
(.1 kW) delivered at simmer
Infrared Charbroiler 16,000 Btu/hr (4.7 kW)
Infrared Griddle – Natural Gas 15,000 Btu/hr (4.4 kW)
LP Gas 13,000 Btu/hr (3.8 kW)
Double Griddle (two burners)
Natural Gas 15,000 Btu/hr (4.4 kW)
LP Gas 13,000 Btu/hr (3.8 kW)
French Top 15,000 Btu/hr (4.4 kW)
Electrical Supply Requirements 110/120 V AC, 50/60 Hz
15 amp dedicated circuit
Power Cord 6' (1.8 m) power cord with
3-prong grounded plug
Shipping Weight 240 lbs (109 kg) – 280 lbs (127 kg)
Specifications are subject to change without notice.
MODEL OPTIONS
Six Burners / Charbroiler SRT486C
Six Burners / Griddle SRT486G
Four Burners / Charbroiler
and Griddle SRT484CG
Four Burners / Double
Griddle SRT484DG
Four Burners / French Top SRT484F
Natural gas model listed, for LP gas add
(-LP) to the model number.
VENTILATION OPTIONS
48" (1219) Pro wall hood or liner
54" (1372) Pro wall or island hood
Refer to the Wolf Pro Ventilation section
of our website, wolfappliance.com for
additional information.
ACCESSORIES
5" (127) or 10" (254) classic
stainless steel riser
20" (508) classic stainless steel
riser with shelf
Black control knobs
Chrome or brass bezels
One-piece wok grate and single
burner grate
Porcelain-coated cast iron two-
burner S-grate
Hardwood cutting board (griddle
models only)
High altitude conversion kits
Accessories are available through
your Wolf dealer. To obtain local dealer
information, visit the Locator section
of our website, wolfappliance.com.
IMPORTANT NOTE: A minimum 10" (254) riser is required for
charbroiler (C) or griddle (G) models installed against a combustible
surface.
Planning Information
48" (1219) Sealed Burner Rangetops
INSTALLATION
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
DIMENSIONS
Rough Opening Width 48" (1219)
Rough Opening Height 71/2" (191)
Rough Opening Depth 24" (610)
Location of Electrical and Gas Supply Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
VENTILATION HOOD
48" (1219)
FINISHED ROUGH OPENING WIDTH
30"min (762) TO
36"max (914)
TO BOTTOM OF
VENTILATION HOOD
36"min (914)
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
44"min (1118)
FOR CHARBROILER
LOCATION OF GAS AND
ELECTRICAL SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
3/4" (19) PLATFORM
TOP VIEW
OF PLATFORM
EG
16"
(406)
16" (406)
4" (102) BACK
WALL
ISLAND INSTALLATIONS: 12" (305) MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0" (0) TO NON-COMBUSTIBLE MATERIALS
36"
(914)
18"min (457)
TO COUNTERTOP
3/4" (19)
PLATFORM
81/2"
(216)
COOKING
SURFACE
71/2"
(191)
24" (610)
13" max
(330)
6"min (152)
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
Planning Information
48" (1219) Sealed Burner Rangetops
INSTALLATION
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
INSTALLATION NOTES
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf
sealed burner rangetop to avoid any fires or
damage to adjacent cabinetry or kitchen equip-
ment. Follow the minimum clearances estab-
lished in the finished rough opening dimensions
as shown in the Installation illustration.
The platform for the rangetop must be 3/4"
(19) thick and include a cut-out at the right rear
for gas supply and electrical connections. The
platform must be level to ensure that the
cooking surface is level.
IMPORTANT NOTE: A minimum 10" (254) riser
is required for charbroiler (C) or griddle (G)
models installed against a combustible surface.
It is recommended that you use a Wolf Pro
wall or island ventilation hood or hood liner
with the Wolf sealed burner rangetop. Refer to
the Pro Ventilation section of our website,
wolfappliance.com.
The Wolf sealed burner rangetop requires a
110/120 V AC, 50/60 Hz electrical supply to
operate the electronic ignition system. The
power supply cord is equipped with a 3-prong,
grounded plug for protection against shock
hazard. The service should have its own 15
amp circuit breaker. Locate electrical and gas
supply within the shaded area shown in the
Installation illustration.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf sealed burner rangetops are designed
to operate on natural gas at 5" (12.5 mb) WC
(water column) pressure or LP (propane) gas at
10" (25 mb) WC pressure. The minimum line
pressure for natural gas is 7" (17.5 mb) WC and
11" (27.4 mb) WC for LP gas. The maximum
gas supply pressure to the regulator should
never exceed 14" (34.9 mb) WC; .5 psi (3.5
kPa).
If local codes permit, a certified, 3' (.9 m)
long, 1/2" or 3/4" ID flexible metal appliance
connector is recommended for connecting the
rangetop to the gas supply line.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the
rangetop in an accessible location.
Wolf sealed burner rangetops using natural
gas will operate up to an altitude of 8,000'
(2438 m) without any adjustment. Natural gas
and LP gas installations from 8,000' (2438 m)
to 11,000' (3353 m) need the high altitude
conversion kit. Contact your Wolf dealer for
details. To obtain local dealer information, visit
the Locator section of our website, wolfappli-
ance.com.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.

This manual suits for next models

5

Other Wolf Burner manuals

Wolf Rangetop User manual

Wolf

Wolf Rangetop User manual

Wolf Dual Fuel Range User manual

Wolf

Wolf Dual Fuel Range User manual

Popular Burner manuals by other brands

Eclipse AH-MA DualBlock Design guide

Eclipse

Eclipse AH-MA DualBlock Design guide

Ecoflam BLU 1700.1 PRE Series manual

Ecoflam

Ecoflam BLU 1700.1 PRE Series manual

Riello RS 35/E BLU Installation, use and maintenance instructions

Riello

Riello RS 35/E BLU Installation, use and maintenance instructions

Ivation IVABMT05 user guide

Ivation

Ivation IVABMT05 user guide

Enertech Nu-Way NG Series Installation & maintenance manual

Enertech

Enertech Nu-Way NG Series Installation & maintenance manual

Enertech Bentone BFG1 Installation and maintenance  instruction

Enertech

Enertech Bentone BFG1 Installation and maintenance instruction

baltur GI Series Instruction

baltur

baltur GI Series Instruction

Eclipse TA Series installation guide

Eclipse

Eclipse TA Series installation guide

baltur BGN 200 LX Instruction

baltur

baltur BGN 200 LX Instruction

Unigas K990A installation manual

Unigas

Unigas K990A installation manual

Mason-Lite MFP39VF Assembly, installation and operation instructions

Mason-Lite

Mason-Lite MFP39VF Assembly, installation and operation instructions

Riello RS 160/M BLU instruction manual

Riello

Riello RS 160/M BLU instruction manual

Riello Burners Gulliver RG5D Installation, use and maintenance instructions

Riello Burners

Riello Burners Gulliver RG5D Installation, use and maintenance instructions

Riello RLS 160/M MX Installation, use and maintenance instructions

Riello

Riello RLS 160/M MX Installation, use and maintenance instructions

Octagon bio 3 user guide

Octagon

Octagon bio 3 user guide

Riello RS 68/EV ULX Installation, use and maintenance instructions

Riello

Riello RS 68/EV ULX Installation, use and maintenance instructions

Riello RS 68/M BLU Installation, use and maintenance instructions

Riello

Riello RS 68/M BLU Installation, use and maintenance instructions

Midco LNB 500 Series Installation and service instructions

Midco

Midco LNB 500 Series Installation and service instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.