Wolf WF-300 Troubleshooting guide

Wolf WF-300 LED Floodlite
Operation and Maintenance Instructions
Please Retain – Read Before Use
EC Declaration of Conformity
The Wolf WF-300 LED Floodlite meets all relevant
provisions of the 94/9/EC (ATEX Equipment) Directive
by virtue of the issued EC Type Examination
Certificate, demonstrating compliance with all relevant
Harmonised Standards and Essential Health and
Safety Requirements.
The Wolf WF-300 LED Floodlite is a high performance
lightweight portable floodlight. Constructed in marine
grade aluminium, with a polycarbonate lens: the end
user must check that these materials are suitable for
the atmosphere the Floodlite will be used in. The
Floodlite can be used in Zone 1 and Zone 2 potentially
explosive gas, vapour, mist and dust atmospheres
where the surface temperature / temperature class
and gas group permit.
The incoming mains cable should not exceed a
temperature rise of 61oC above the ambient
conditions; select suitable cable and cable gland.
II 2GD Ex emb IIC T4 Gb (Ta = -20oC to +50oC)
Ex t IIIC T103oC Db IP66 & IP67
EC Type Examination Certificate:
Notified Baseefa Ltd.
Body: Rockhead Business Park, Staden
Lane, Buxton, SK17 9RZ, UK
Notified body number: 1180
Harmonised standards applied:
EN60079-0:2006, EN60079-7:2007,
EN60079-18:2009, EN61241-0:2006,
EN61241-1:2004, IEC60079-0:2007.
Wolf LED Floodlites are certified compliant with the
2004/108/EC EMC Directive.
The product is CE marked showing compliance with all
relevant EC Directives
Alex Jackson – Technical Director
Wolf Safety Lamp Company Ltd
IMPORTANT
Read these instructions carefully before commencing
to use the Floodlite and retain for future use.
Check the rating label to ensure the Floodlite is
suitable for the supply provided, ambient
temperature present and IP rating.
ATEX certification includes assessment of product
safety at ±10% of rated voltage, running lamps
outside of this voltage tolerance will therefore
invalidate the ATEX approval and the product
warranty, may result in a dangerous condition, and
could cause the product to fail prematurely.
If the Floodlite is to be used in areas of high
vibration, please consult with Wolf Safety.
ELECTROSTATIC CHARGING HAZARD Clean
lens with damp cloth.
The Floodlite consists of an Ex mb LED chamber
and an Ex emb terminal chamber.
All Floodlites have terminal blocks suitable for up
to 4mm2live, neutral and earth.
ATEX approved cable glands must be used and
be suitable for the type of cable used. Any unused
cable entries should be blanked off with a suitable
ATEX approved stopper plug to maintain a
minimum IP66/67 rating as marked on the label.
Special conditions for safe use (denoted by X
after the certificate number)
Always use the lamp in the bridle provided.
Except for internal wiring, not more than one
single or multiple strand lead shall be
connected into either side of any terminal,
unless multiple conductors have been joined
in a suitable manner, e.g. two conductors into
a single insulated crimped boot lace ferrule.
Leads connected to the terminals shall be
insulated for the appropriate voltage and this
insulation shall extend to within 1 mm of the
metal of the terminal throat.
When terminals in accordance with certificate
IECEx SIR 05.0035U are used, all terminal
screws, used and unused, shall be tightened
down to between 0.5 Nm and 0.7 Nm.
When terminals in accordance with certificate
IECEx SIR 05.0037U are used, all terminal
screws, used and unused, shall be tightened
down to between 1.2 Nm and 2 Nm.
Wolf Safety Lamp Company
WWW.CABLEJOINTS.CO.UK
THORNE & DERRICK UK
TEL 0044 191 490 1547 FAX 0044 477 5371
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK

When terminals in accordance with
certificates IECEx SIR 05.0035U and IECEx
SIR 05.0037U are used, they shall only be
installed and wired with cable within a
temperature range of -10°C to 80°C.
When cross-connecting combs are used on
terminals to certificates IECEx SIR 05.0035U
and IECEx SIR 05.0037U, the relevant
conditions of certification associated with
those certificates shall be applied.
Cable entry holes shall be fitted with either an
appropriately certified cable gland or
appropriately certified blanking element.
These shall provide and maintain a minimum
enclosure ingress protection of IP66 or IP67
as appropriate.
The LED assembly must be replaced
following the failure of a maximum of 8
individual LED’s.
Internal fuse replacement must be the correct
fuse value and be capable of withstanding a
short circuit current of 1500A.
User must ensure that when used, the
protective film must remain fixed in place at all
times when the equipment is being moved.
If the Floodlite head is not situated within the
protective frame/stand ensure the unit is de-
energised before moving.
MAINTENANCE
1. Isolate the Floodlite from the mains supply
and allow to cool before carrying out any
maintenance work.
2. It is essential that all Floodlites are maintained
in accordance with the requirements of
EN60079-17.
3. The cable should be inspected before each
use. Regular close inspections must be
carried out to ensure the cable is not
damaged in any way. Particular attention
should be paid to gland and socket entries.
4. IMPORTANT. No modifications are permitted
to the Floodlites, all spare parts must be
purchased from the manufacturer,
unauthorized modifications or spare parts will
invalidate certification.
ELECTRICAL DATA
Total circuit watts 60W, power factor correction
better the 0.95. Voltage range 100V to
254V +/-10% 50/60Hz or 24V +/-10% AC/DC –
see rating label.
CHANGING LED ASSEMBLIES
Isolate the Floodlite, remove the lid assembly by
releasing the 4 socket head bolts that are
retained in the polycarbonate cover, the inner
LED assembly can now be removed by releasing
the 4 socket head screws, the casting with the
encapsulated LED’s can now be discarded.
Fitting a new LED assembly is a reversal of the
above procedure.
DISPOSAL OF WASTE MATERIAL
Disposal of packaging, Floodlite and old LED
assemblies should be carried out in accordance
with national regulations.
IECEx Scheme Certification
IECEx Scheme Certificate Number:
IECEx BAS 10.0016
Ex emb IIC T4 Gb (Ta= -20oC to +50oC)
Ex t IIIC T103oC Db IP66 & IP67
IEC Standards applied:
IEC60079-0:2007, IEC60079-18:2009, IEC60079-
7:2006/07, EN61241-1:2004
WARNING: USE ONLY GENUINE WOLF
REPLACEMENT PARTS.
The Wolf Safety Lamp Co. Ltd has a policy of
continuous product improvement. Changes
in design details may be made without prior
notice.
SPARE PARTS
Description Wolf Part Number
Protective Lens Film 3 pack WF-650/3
Stand and Bridle WF-698K
Stainless Bolt Pivot Kit WF-641
4 off Stainless Bolt and ‘O’ Ring kit WF-645
Polycarbonate Lens Cover with Seal WF-647
LED Panel WF-649
Trumpet Gland LL-311
EX Terminal block WF-653
Internal Fuse Low Voltage (24V) WF-262
Internal Fuse High Voltage (110-230V) WF-264
Wolf Safety Lamp Company
WWW.CABLEJOINTS.CO.UK
THORNE & DERRICK UK
TEL 0044 191 490 1547 FAX 0044 477 5371
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK
Other Wolf Floodlight manuals
Popular Floodlight manuals by other brands

REV Ritter
REV Ritter Akku Flood Assembly and operating instructions

Event Lighting
Event Lighting PARRGBW12x8 user manual

Chauvet
Chauvet mini kinta IRC user manual

Steren
Steren LAM-835 instruction manual

ADJ
ADJ Flat Par QWH5X User instructions

Ribimex
Ribimex Ribitech PRSPOT12PBAT User and maintenance manual