•Leads connected to the terminals shall be
insulated for the appropriate voltage and this
insulation shall extend to within 1 mm of the
metal of the terminal throat.
•When terminals in accordance with certificate
IECEx SIR 05.0035U are used, all terminal
screws, used and unused, shall be tightened
down to between 0.5 Nm and 0.7 Nm.
•When terminals in accordance with certificate
IECEx SIR 05.0037U are used, all terminal
screws, used and unused, shall be tightened
down to between 1.2 Nm and 2 Nm.
•When terminals in accordance with
certificates IECEx SIR 05.0035U and IECEx
SIR 05.0037U are used, they shall only be
installed and wired with cable within a
temperature range of -10°C to 80°C.
•When cross-connecting combs are used on
terminals to certificates IECEx SIR 05.0035U
and IECEx SIR 05.0037U, the relevant
conditions of certification associated with
those certificates shall be applied.
•Cable entry holes shall be fitted with either an
appropriately certified cable gland or
appropriately certified blanking element.
These shall provide and maintain a minimum
enclosure ingress protection of IP66 or IP67
as appropriate.
•The LED assembly must be replaced
following the failure of a maximum of 8
individual LED’s.
•Internal fuse replacement must be the correct
fuse value and be capable of withstanding a
short circuit current of 1500A.
•User must ensure that when used, the
protective film must remain fixed in place at all
times when the equipment is being moved.
•If the Floodlite head is not situated within the
protective frame/stand ensure the unit is de-
energised before moving.
MAINTENANCE
1. Isolate the Floodlite from the mains supply
and allow to cool before carrying out any
maintenance work.
2. It is essential that all Floodlites are maintained
in accordance with the requirements of
EN60079-17.
3. The cable should be inspected before each
use. Regular close inspections must be
carried out to ensure the cable is not
damaged in any way. Particular attention
should be paid to gland and socket entries.
4. IMPORTANT. No modifications are permitted
to the Floodlites, all spare parts must be
purchased from the manufacturer,
unauthorized modifications or spare parts will
invalidate certification.
ELECTRICAL DATA
Total circuit watts 60W, power factor correction
better the 0.95. Voltage range 100V to
254V +/-10% 50/60Hz or 24V +/-10% AC/DC –
see rating label. PAT testing, maximum insulation
testing may be carried out at voltages less than or
equal to 500V DC, if the Live and Neutral cables
are shorted together and the voltage applied
between earth and this connection.
CHANGING LED ASSEMBLIES
Isolate the Floodlite, remove the lid assembly by
releasing the 4 socket head bolts that are
retained in the polycarbonate cover, the inner
LED assembly can now be removed by releasing
the 4 socket head screws, the casting with the
encapsulated LED’s can now be discarded.
Fitting a new LED assembly is a reversal of the
above procedure.
DISPOSAL OF WASTE MATERIAL
Disposal of packaging, Floodlite and old LED
assemblies should be carried out in accordance
with national regulations.
IECEx Scheme Certification
IECEx Scheme Certificate Number:
IECEx BAS 10.0016
Ex emb IIC T4 Gb (Ta= -20oC to +50oC)
Ex t IIIC T103oC Db IP66 & IP67
IEC Standards applied:
IEC60079-0:2007, IEC60079-18:2009, IEC60079-
7:2006/07, EN61241-1:2004
WARNING: USE ONLY GENUINE WOLF
REPLACEMENT PARTS.
The Wolf Safety Lamp Co. Ltd has a policy of
continuous product improvement. Changes in
design details may be made without prior notice.
SPARE PARTS
Description Wolf Part Number
Protective Lens Film 3 pack WF-650/3
Stand and Bridle WF-698K
Stainless Bolt Pivot Kit WF-641
4 off Stainless Bolt and ‘O’ Ring kit WF-645
Polycarbonate Lens Cover with Seal WF-647
LED Panel WF-649
Trumpet Gland LL-311
EX Terminal block WF-653
Internal Fuse Low Voltage (24V) WF-262
Internal Fuse High Voltage (110-230V) WF-264
Wolf Safety Lamp Company
Saxon Road Works, Sheffield, S8 0YA, England
Tel: +44 114 255 1051 Fax: +44 114 255 7988
E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk
WF-429 issue 7