Wonwoo Rapport 337 User manual

www.rapport337.com

Manufacturer : Wonwoo Engineering Co., Ltd.
www.rapport337.com Made in Korea
Distributed by:

T
T
ABLE OF CONTENTS
Before Reading the User's Manual 1
1. Safety Information 2
WARNING 2
2. Introduction of Rapport337 7
Names & Functions of Each Part 9
3. Specifications of Rapport337 14
General Specifications 14
Meter Specifications 15
4. Functional Use 17
Power ON/OFF 17
OSD Setup Screen when Power is on 17
Mode Setup 18
VIDEO TESTER 19
DIGITAL MULTI METER 22
PTZ CONTROLLER 29
UTP CABLE TESTER 34
VIEW INFORMATION 35
MAIN SETTING 35
www.rapport337.com

MEMO

B
B
ef or e Reading the User Õs Manual
W A R N I N G
Make sure to read through "Safety Information" before using
Rapport337.
This basic instruction manual is for users of Rapport337. Starting
with the outline of Rapport337, the manual is emphasized on the
explanations of its operation, how to be connected to the other
devices, how to use every button, and how to set up the system.
It is highly recommended, for those who have handled similar
devices as well as for those who are using it for the first time, to
read every description line by line, especially cautions, before using
the Rapport 337.
And when there is any question when in use or there is any
damage, make sure to contact the dealer of your Rapport337.
In the 1st Chapter "Safety Information" , warnings and
precautions are explained for the safety of users when Rapport337
is in use.
In the 2nd Chapter "Introduction of Rapport337" , its features
and appearance are explained.
In the 3rd Chapter "Specifications of Rapport337" , the
specification of the rapport337 components are explained.
In the 4th Chapter "Functional Use" , the functions of Rapport337
are explained so that the users can use it conveniently.
1
www.rapport337.com

1
1
. Saf ety Inf or mation
2
W A R N I N G
ඝThe following is important to use Rapport337 safely.
First of all, read through "the precautions for your safety " before
using the system.
Make sure to check the input and output range of voltage or current
at every input and output ports of Rapport337 before connecting
each of them, so that the system cannot be overloaded when in
use.
Set up the range for measuring voltage, current and resistance for
their known values and use the maximum range for unknown values
to protect the unit from damage.
www.rapport337.com

The following operational environment should be maintained
constantly for the proper use of Rapport337.
㯲
㯲
Temperature : -10 ~ 50
㯲Relative humidity : 30% ~ 90%
㯲Recharging voltage : 12V ·G10%, above 1A
1 . Saf ety Inf ormation
3
When the meter function is being used, do not connect any device
to the VIDEO IN/OUT terminals at that time, as the grounding could
cause any damage or trouble to both of them.
www.rapport337.com

4
W A R N I N G
ඝ
Pay attention to the following precautions when using
Rapport337.
Do not use the unit in damp humidity or leaking gas environments.
Do not touch it with wet hands.
Be mindful not to shock or shake the unit while in use to avoid
damage.
Avoid the places of strong magnetism or electric wave, which
would cause incorrect measuring.
Be careful not to expose the ports or joints to dirt or liquid.
Make sure to use specified replacement fuses described in the
3rd chapter.
Do not disassemble the Rapport 337.
Do not use the meter function, when the Rapport337 or the lead
set look damaged.
Do not measure resistance when the power is applied to a circuit.
When using the meter function, do not forget to turn on the power
of Rapport337 and set up the proper measurement mode before
connecting to a circuit to be measured.
Turn off the power to the circuit to be measured and discharge all
high voltage capacitance before starting resistance or continuity
tests to avoid damage to the Rapport 337.
Put the finger behind the protecting pad when using a probe.
www.rapport337.com

1 . Saf ety Inf ormation
5
W A R N I N G
ඝBattery Charging & Its Precautions
With the rechargeable 6 nickel hydrogen
(Ni-MH) AA-size batteries placed in,
Rapport337 can be charged with an
adopter of above DC 12V, 1A, and it
takes more than 8 hrs for the battery to
be fully charged.
The battery operates normally after initial
2 or 3 times of full charging, and it can be
used for about 3 hrs and above.
The battery charging can be checked on
the initial picture of POWER ON, and
also confirmed on the VIEW INFORMATION.
The battery is recharged when connected
to a DC adopter irrespective of the Power
slide S/W or button.
Alkaline battery(AA size) is usable for
about 2 hrs.
AUX
IN
DC12V
UTP
CABLE TEST
T R
DC12V, 1A
T R
www.rapport337.com

6
- Cautions for Battery -
The following batteries can be used for Rapport337
- (AA)-size alkaline battery (6EA)
- (AA)-size chargeable nickel hydrogen (Ni-MH) battery (6EA)
Use only chargeable nickel hydrogen (Ni-MH) batteries, when charging
batteries,using an adapter to Rapport337.
Place the CHARGE SWITCH "ON" position for recharging.
The CHARGE SWITCH is located on the upper part of battery insert.
(Refer to the figure below)
The performance of batteries can be very different, according to
manufacturers. Please use any reliable brand.
Do not mix batteries of different manufacturers when charging batteries.
Make sure not to disorient the polarization of batteries.
Do not short-circuit or disassemble batteries.
Make sure to check the polarization and the voltage and current
ratings before charging batteries and disconnect the charger
immediately should an abnormal situation arise.
www.rapport337.com

2. Intr oduction of Rappor t33 7
7
FEATURES
As a handy and portable device designed for testing various appliances, for
the image-output equipments to be installed, Rapport337 is an efficient
tester with useful testing functions, to assist the installation of CCTV, UTP
test, communications test, RS-485 communications inspection, etc.
For testing each function, set up modes and capacities to be tested, using
the key pad located on the front part of Rapport337.
Main Functions of RAPPORT337
Video tester ඖThe video signal and the quality of picture
can be tested, and brightness, color and
focus can also be adjusted while the image
is being watched.
ඖVideo signal generator mode : lt outputs color
bar Red, Blue and Green screen to allow
technician to inspect video monitor or DVR.
Support both PAL & NTSC video signal format.
Multimeter ඖVoltage, current, resistance, short-test can be
tested.
PTZ Controller ඖThe basic operational test of PTZ, and other
tests of focus and image checkup, etc. that
are needed for the installation of PTZ are
possible.
It supports RS-485/422 communications
mode.
UPT Cable tester ඖThe wiring condition(disconnected, shorted)
of UTP cable can be checked out.
www.rapport337.com

8
Standard Items
Check the contents of your Rapport337 package with the standard checklist
below placing them on a level place.
Rapport337 Main Body
User's Manual
Test Lead Set(Red, Black)
Adapter
Rechargeable AA(Size) Nickel Hydrogen(Ni-MH) Battery (6EA)
Necklace
UTP test Terminal
BNC Video Cable
Car Power jack
Optional Items
㯲Tester Bag
www.rapport337.com

2. Intr oduction of Rappor t33 7
9
ඝNames & Functions of Each Part
10A mA V/
FAR +TELE
-
SETMODE OSD
PWR
N
E
A
R
W
I
D
E
PWR CHG Rx
Tx
BRIGHT CONTRAST
1
2
4
5
6
7
8
3
MAX
400mA
10A MAX 400V AC
MAX
500V MAX
400V DC
FUSED
UN FUSED
RAPPORT337
www.rapport337.com

10
Part Name Function
ྞKey Button Controlling External Devices of Rapport337
MODE Button
SET Button
OSD Button
FAR Button
NEAR Button
TELE Button
WIDE Button
Shift Setup
Button
Mode Select
(Video, Multi Meter, PTZ Control, UTP Test)
It is used when setup is changed
It toggles OSD & POWER on/off
It adjusts PTZ focus (far direction) &
Video Mode Brightness
It adjusts PTZ focus (near direction) &
Video Mode Brightness
It zooms PTZ(zoom in) &
adjusts Video Mode Contrast
It zooms PTZ(zoom out) &
adjusts Video Mode Contrast
It shifts up, down, right, left for PTZ &
for menus & others
Power LCD
Charge
Indicating LED
Data Transmitting
LED
Data Receiving
LED
LCD
Red LED is on when the system is switched on
Green LED is on when being charged
Red LED is on when data is transmitted
Red LED is on when data is received
TFT LCD
ྙ
ྚ
ྛ
ྜ
ྜྷ
www.rapport337.com

2. Intr oduction of Rappor t33 7
11
Part Name Function
ྟKey Button METER PART
ྠTest Lead Connection Test Lead Positioning for Lead Connection
Resistance
Button
Voltage Button
Setup Change
Button
Current
Measuring
Button 1
Current
Measuring
Button 2
Current
Measuring
Button 3
HOLD, HELP
Button
It measures resistance
It measures voltage
IT changes setup of AC/DC,
resistance/continuity test
It is used for measuring lower current below 4 mA
It is used for measuring current below 400 mA
It is used for measuring current below 10A
Measuring range can be changed and holded
HELP function
It indicates position of Red Test Lead for measuring
Voltage & Registance
It indicates position of Black Test Lead
It indicates position of Red Test Lead for measuring
Current below 400mA
It indicates position of Red Test Lead for measuring
Current below 10A
www.rapport337.com

12
Part
ྙ
ྚ
ྛ
ྜ
ྜྷ
ྞ
12
5
4
6
3
Name
Input BNC
Output BNC
Communication
Port
Base
Safety hook Up
Safety hook
Down
Function
It inputs external image signal
It outpus input image signal to Rapport337
or internally generated Video Test Signals
It is the port of input & output of communication
signal.(Rx+, Rx-,Tx+,Tx-)
It braces Rapport337
It hangs on the neck for safety
It hangs on the neck for safety
www.rapport337.com

2. Intr oduction of Rappor t33 7
13
Part
ྙ
ྚ
ྛ
ྜ
1
4
2
3
Name
UTP Jack
AUX Jack
DC Power Jack
Power S/W
Function
Test jack for UTP cable
Audio, AUX input port
(function to be added when upgraded)
DC power input jack(for over DC12V,1A)
ON/Off main power supply
www.rapport337.com

3
3
. Specif ications of Rappor t3 3 7
14
ඝGeneral Specifications
Electric
Characteristic
Image
PTZ
operation test
UTP Cable
Test
Size
Input Voltage
Battery
Built-in Charger
TV Type
Image level
Protocol
Transmission
speed
Transmission
mode
Kinds of test
12V ·10%, above 1A
Chargeable Ni-MH battery 6EA (AA size)
NTSC/PAL
1 Vpp, 140IRE
Multi-Protocol support
2400bps ~ 38400bps
RS-422,RS-485
direct/cross cable, and broken or short-circuit
can be tested
Charging Time
Operation time
Above 8 hrs
More than 3 hrs
W(88mm) X L(190mm) X T(58mm max)
www.rapport337.com

3 . Specif ications of Rappor t3 37
15
ඝMeter Specifications
DC Voltage
AC Voltage
DC Current
400mV
4V
4V
400V
4V
40V
400V
100uV
1mV
10mV
100mV
1mV
10mV
100mV
0.2uA
2uA
20uA
200uA
2mA
·(0.8% + 2dgts)
·(1.0% + 2dgts)
·(1.2% + 3dgts)
(40H ¡G~ 500H ¡)
·(1.0% + 2dgts)
·(1.5% + 2dgts)
·(2.0% + 3dgts)
Measuring Measured Value Minimum Accuracy
Item Measuring
4mV
400mV
10A
400uA
4mA
40mA
400mA
10A
www.rapport337.com

16
AC Current
Resistance
Continuity
Rated fuse
400 ˟
4༮
40༮
400 ༮
4༯
40༯
0.2uV
2uV
20uV
200uV
2mV
0.1 ˟
1˟
10˟
100 ˟
1༮
10༮
·(1.5% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
·(1.8% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
·(3.0% + 4dgts)
40Hz ~ 500Hz
·(1.0% + 4dgts)
·(1.0% + 2dgts)
·(2.0% + 4dgts)
·(3.0% + 5dgts)
Measuring Measured Value Minimum Accuracy
Item Measuring
4mV
400mV
10A
400uA
4mA
40mA
400mA
10A
Beeper is activated when the resistance is below 80 ˟
250 Volt 800 mA
www.rapport337.com
Table of contents