Woodbridge WIC71-A User manual

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Model:WIC71-A
INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING
OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
2 PEOPLE ARE REQUIRED TO LIFT AND DURING
ENTIRE INSTALLATION OF THIS PRODUCT
Installaon Instrucon for Wooden Cold Plunge
Limited warranty is void on any commercial installaon
We are not responsible for local code compliance for this product. Building and plumbing codes may vary from state-to-state in
accordance to your locaon. We are not resonsible for providing any compliance cerficaons.
Under no circumstances we are not liable for any and all incidental damages sustained in connecon with this product.
Neither manufacture, distributor or retailer is responsible for water damage or flood caused to use of this product.
Under no circumstances We shall not be liable for any and all fees, cost of installaon/reinstallaon/removal, subsequent
damage or transportaon in case of the product defect
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
1.Pre-Cauon
Before Installaon
①Your chiller may not include the refrigerant due to transportaon security regulaon, When you get the product, please
check if the chiller came with refrigerant or not, unit running without refrigerant can easily cause damage to the machine
and stop working!
②Ensure your wall outlet voltage is meeng and within the rated voltage of the chiller.
③Power switch should be set to at least 4’6”/1.4M height from floor or above the height that it cannot be reached by
children.
In use
①Do not turn on the cold plunge without irrigang water! Prevents the pump from idling and burning.
②Keep the air flowing smoothly around the machine, the heat venlaon hole shouldn’t be blocked by any obstacles.
Aer use
①Please cover the cold plunge to prevent debris such as dirt, sand and leaves from floang into the tub that might cause
water blockage aer use.
②With the environmental temperature below 32°F (including 32°F), the water in the heat exchange and water tank will
freeze, resulng in cracking. Drain water when not in use for a long amount of me.
2.Safety Regulaons
① The bathtub must be installed and used in accordance to the this user’s manual.
② Children under 12 years old must be under the supervision of an adult to use, avoid playing with the device to prevent
danger.
③ Never use bathtub while intoxicated, aer taking meals or any alcoholic beverages. Consuming alcoholic beverages before
or during bathing will cause drowsiness and may result in hypothermia, loss of consciousness, or even drowning.
④ DO NOT insert objects such as fingers or scks into the chiller element to prevent danger.
⑤ DO NOT use hair dryer, lights, telephone, television, radio, or other electrical appliances within 5 feet of the bathtub.
⑥ DO NOT overfill the tub before geng in the water. Filling up can lead to spills and slippery condions when entering
the tub. Be extremely careful when entering and exing the tub.
⑦ If you are using any medicaons or have adverse medical history, you must consut a physician prior to use of the bathtub
to avoid potenal hypothermia or possible drowning.
⑧ It is advised to not use for those with skin erosion or unhealed wounds.
⑨ Water temperature above 100°F may cause hyperthermia and/or other health problems. Check the water temperature
and adjust to your personal comfort.
⑩The power cord plugs, sockets or switches of the equipment should be located in places out of the reach of children,
and should be protected from rain to prevent danger.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
3.Product informaon
Product Name: Wooden Cold Plunge
Model: WIC71-A
Size:71.8 x 47.7 x 24.6
Capacity:1 person
Material: Thermo Rubber Wood + Stainless Steel Liner
24-5/8″
47-3/4″
58-1/4″
69-1/2″
26-7/8″
71-7/8″
1-5/8″
SIDE VIEW
SIDE VIEW
CHILLER
INSIDE VIEW
DRAIN
BACKREST
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Power plug
Chiller
Outlet
Inlet
Filter
Outlet
Inlet
Ice tub
Principle diagram
Working principle
The water pump pumps the water from the bathtub cools down the waters temperature through the chiller system,
and then delivers the low-temperature water back to the bathtub.
The chiller heats the water in the unit, so the water temperature rises and then delivers water back to the bathtub to
achieve the effect of heang.
The front view of the display
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
4.Installaon Instrucon
Chiller installaon
①Install the chiller in a stable place to avoid the impact of water backflow.
②The chiller should be in a clean place, avoid blocking the exhaust port.
③Install the chiller in a well-venlated place to facilitate the exhaust of the chiller.
Chiller connected to power
①Please observe safety precauons before any power connecon acon.
②Connecng or replacing wiring should comply with electrical specificaons and should be performed by cerfied
electrician or professionals.
③Make sure that the power supply voltage and frequency of the chiller are consistent with the power supply voltage
Chiller add refrigerant
①The fan of the chiller rotates and blows out the hot air, which is normal work. On the contrary, insufficient refrigerant
or no refrigerant, contact HVAC professional to add refrigerant according to our ps.
②Precauons for adding refrigerant.
A. Before adding refrigerant, be sure to use a vacuum pump to evacuate for 30 minutes.
B. Aer vacuuming, connect the refrigerant tank and the pipeline.
C. Vent the pipe (Do not add refrigerant)
D. Put the refrigerant tank on the electronic scale for weighing, and then add refrigerant quantavely according to the
nameplate requirements.
Cold plunge installaon
① The cold plunge should be installed on a leveled and stable posion to avoid the influence of water backflow.
② Small pipe diameter will affect the water flow and cause the refrigeraon system to fail to work properly.
③ The hose clamp connecng the hose and the hard pipe should be secured ghtly to prevent the water pipe from slipping.
④ Find a suitable place for the cold plunge to drain to avoid poor drainage in the bathtub.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Power plug
Chiller
Outlet
Inlet
Filter
Outlet
Inlet
Ice tub
Principle diagram
Water level
Only run the pump when water level is higher
than the plunge/tub inlet.
③Water filling
Plug in the water hose into the inlet to prevent the chiller
and water pump running idle.
②Check and make sure the inside of the tub is clean.
The tub should always be clean and without any garbage inside the tub.
5.Cold Plunge Set Up
1.Preparaons before starng up.
①Check and make sure the inlet is unobstructed
The water inlet should be kept unobstructed, as shown in the figure.
Inlet
Outlet
Water level
Inlet
Outlet
Water pipe
Inlet
Outlet
④Connue to fill water so that the water level cover the
inlet and outlet.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
⑤ Use water hose to fill water into the water inlet, the
water outlet will connue to bubble out, manually
get rid of any air in the chiller.
⑦Press the "Set" key to set the temperature, and then press the up or down key to adjust to appropriate temperature;
Finally, press the Run key. As shown below.
⑥ Aer 2-3 minutes of water filling unl no air bubbles come out
from the water outlet, remove the water hose.
3.Start running2.Press up or down key1.Press
Icon Name
Run key
Set key
Up key
Down key
Sterilizer
Descripon
Press once to stop cooling / heang, and then press
again to turn on cooling / heang.
Press once to enter the target temperature seng,
press and hold for 6 seconds to enter the menu, and
enter the correct menu password to enter the menu
to modify the operang parameters.
to adjust parameters upward.
to adjust parameters downward.
to turn on/off the O3/UV output
Uv
O3
⑧The chiller requires 3 minutes warm up me from start running to cooling,as shown below.
KEY
No bubbles come out
Water hose
Bubbles coming out
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Display
RS 485
turnUSB
A
B
Installaon posion:
evaporator
Leakage switch
Flow
Switch
Low Pressure
Switch
High Pressure
Switch
Compressor Fan Four way valve Water pump Oxygen pump Lighng
NL
Icon Light ON Light OFF Light Blinking
Cooling Stop refrigeraon Compressor is delaying
Preset temperature reached Not reaching preset temperature
Heang in progress Stop to heat Compressor is delaying
Defrosng Stop to defrost Compressor is delaying
Connected to the Internet Not connected to the Internet In distribuon network
Refrigeraon
lamp
Constant
temperature
Heang
lamp
Defrost
lamp
Networking
lamp
Name
Indicator light
6. Schemac Diagram
As the wiring reference, the drawing must be adjusted according to the working voltage, power and other aspects of the
corresponding equipment, and the final actual demand adding protecve devices or other components, which can also
be completely wired according to this drawing.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
The equipment has reached the set service
life, please contact manufacturer
Water temperature
sensor failure
The water temperature sensor is damaged,
or the sensor is not properly installed
The compressor pressure is too low, resulng in no
short circuit between the low-pressure detecon
port of the main board and the public
All work stops
Water pump,compressor,fan,
four-way valve
The compressor pressure is too high, resulng in no
short circuit between the high-pressure detecon
port of the main board and the public
When the compressor is working, the current value
exceed the set value of “f13”
The temperature measured by the water temperature
probe exceeds the set value of F11
The temperature measured by the water temperature
probe exceeds the set value of F12
Ultra high temperature
fault
Ultra low temperature
fault
Poor contact of communicaon interface and
communicang line chip
Water shortage leads to no short circuit between
the water flow detecon port of the main board
and the public
Fault code
7. Code Diagram
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Parameter list
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Thermo rubber wood + stainless steel liner
Chiller parameters
Cold plunge Parameters
8.Technical Specificaon
71-7/8″ X 44″ X 24-5/8″
600L/158.5gal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
1.Use a wrench to unscrew the filter
bole and remove the old element
2.Unpack the new filter element and
place it at the boom of the bole
3.Cap the bole and fasten with a wrench 4.Check for water leakage before the
replacement is complete
9.Maintenance
Wooden Tub Maintenance:
①Clean the tub with a so brush or sponge, and rinse it with clean water aer removing the dirt. Do not use the sharp
objects or hard/metal brush to scrape the wooden tub, otherwise it will damage the waterproofer of the wooden tub.
②Depending on different situaon, recommend repainng the wooden tub every 1-2 years or the finish of the wood
get fade.
Stainless Steel Liner Maintenance:
①Please use the warm water, mild soap water and sock the liner for 30 minutes before cleaning. Do not use any alkaline
bleach to clean, otherwise it will destroy the liner protecon layer.
②Please use a so brush or sponge, and rinse with clean water aer removing dirt. Do not scrape the liner with sharp
objects or a sff brush, as this will damage the surface of the liner.
Filter Maintenance Suggeson
①Please replace water filter every 3 to 6 months or when the water flow remains slow aer cleaning.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Step Stool
10.Package Content
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
WARRANTY
R
WOODBRIDGE
This limited warranty is non-transferable and only applies to products purchased and installed in the United States and Canada.
This limited warranty excludes all industrial, commercial and business usage. Proof of purchase (original sales receipt) from the original purchaser, Descripon
and pictures of defect, model number or model descripon must be provided to Woodbridge Bath for all warranty claims and Woodbridge Bath IS NOT
responsible for labor cost, removal or installaon costs.
This limited warranty shall not apply to goods which have been subject to accident, negligence, improper installaon, product abuse, product misuse, or use of
cleaners containing abrasives, alcohol or other organic solvents, whether performed by a contractor, service company, or yourself, are excluded from this warranty.
This warranty does not cover surface damaged caused by use of chemicals that break through or dissolve the surface finish or damage caused by the accidental
dropping of sharp or heavy objects. Improper care and use of abrasive cleaners and will void the warranty.
During this limited warranty period if a malfuncon occurs and aer inspecon it is determined that a defect developed during normal use, Woodbridge will as at
its elecon proceed withon any of the following opons:
(1) repair or replace the defecve part(s) or product(s) at cost
(2) issue a refund of the original purchase price of the product(s) (Valid within 30 days from the date of purchase)
(3) issue a credit to be applied toward the purchase of a new product. Shipping/delivery charges may apply and are in sole discreon.
Cauon:
NEVER use cleaners containing abrasive cleaners, ammonia, bleach, acids, waxes, alcohol, solvents or other productsthat are not recommend for Chrome finish
will void the warranty.
Woodbridge products should be installed by a fully insured and licensed contractor only. Installaon by anyoneother than fully insured and licensed
contractorwillvoid this limited warranty.
Woodbridge warrants its products as listed in below to be free of material and workmanship defect,
subjected to the limitaons set forth in this limited warranty.
· Bathtub, Whirlpool/Air Bubble Massage Tub, Wooden Cold Plunge: 1 Year limited to be free of defects in material and workmanship.
· Toilet and Bidet:1 Year limited to be free of defects in material and workmanship.
· Faucet:1 Year limited to be free of defects in material and workmanship.
· Vanity: 1 Year limited to be free of defects in material and workmanship.
· Granite, Marble, Engineered Quartz Vanity Top: 1 Year limited to be free of defects in material and workmanship.
· Medicine Cabinet, LED Mirror:1 Year limited to be free of defects in material and workmanship.
· Stainless Steel Sink: 1 Year limited to be free of defects in material and workmanship.
· Solid Surface Shower Wall Panel, Shower Base and Vanity Top: 10 Years limited warranty to be free from material defects.
· Shower Door: Lifeme warranty on glass components and 1Year limited on other hardware.
RESPONSIBILITIES OF OTHERS
Inspecng the unit prior to installaon is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for
ensuring the unit is free of defect or damage. Noces are placed on the unit and on the shipping carton advising the installer of this responsibility. In the
event of a problem, the unit must not be installed. Woodbridge is not responsible for failures or damage that could have been discovered, repaired, oravoided
by proper inspecon and tesng prior to installaon.
Damage occurring in transit is the responsibility of the carrier. The user or installer MUST open the crate and inspect the unit for damage when it is delivered.
If damage is discovered, it must be reported immediately to the seller and the carrier in wring, and an inspecon requested. Failure of the carrier to respond
should be reported to the seller and the carrier. Your freight claims should be filed promptly thereaer.
This limited warranty does not cover any liability for consequenal or incidental damages, all of which are hereby expressly disclaimed, or the extension beyond
the duraon of this limited warranty of any implied limited warranes, including those of merchant ability or fitness for an intended purpose.
DISCLAIMER
Except as expressly provided, there shall be no warranty or obligaon, express or implied, oral or statutory. No dealer or other person has the authority to
make any warranes or representaons concerning or its products. In no event shall be held responsible for any such warranes or representaons.
Some states/provinces do not allow limitaons on how long an implied warranty lasts, or the exclusion on limitaon of special, incidental or consequenal
damages, so these limitaons and exclusions may not apply to you. This warranty gives you specific legal rights, you may also have other rights which vary
from state/province to state/province.
To obtain warranty and replacement parts, please send e-mail to [email protected] the original receipt informaon, Woodbridge will determine
whether to repair or replace your product, issue a refund or issue a credit.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
Retain these installaon instrucons for future reference!
Thank you for using WOODBRIDGE products!
IMPORTANT!
DO NOT USE: Abrasive cleaners such as: acid, ammonia, bleach, and similar soluons. Use of such soluons may cause
corrosion, finish peeling, and/or dull the surface.
DO NOT USE: Abrasive sponges or cloth. Never use steel, wool, or wired brushes that will permanently scratch the
Please don't hesitate to contact us if you have any quesons or concerns.
Customer Service Phone: 562-229-0088. (Monday - Friday 9 AM - 5 PM Pacific Time)
Or Email: [email protected]om
R
WOODBRIDGE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com Update:20230905
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Modèle:WIC71-A
La garane limitée est nulle sur toute installaon commerciale
Nous ne sommes pas responsables de la conformité au code local pour ce produit. Les codes du bâment et de la plomberie
peuvent varier d’un état à l’autre en foncon de votre emplacement. Nous ne sommes pas responsables de fournir des
cerficaons de conformité.
En aucun cas, nous ne serons responsables de tout dommage accidentel subi en relaon avec ce produit. Ni la fabricaon, ni le
distributeur, ni le détaillant ne sont responsables des dégâts d’eau ou des inondaons causés par l’ulisaon de ce produit.En
aucun cas Nous ne serons pas responsables de tous les frais, frais d’installaon / re-installaon/enlèvement, dommages
ultérieurs ou transport en cas de défaut du produit.
INSTRUCTIONS QUI, SI IGNORÉES POURRAIENT ENTRAÎNER LA MORT OU DES BLESSURES GRAVES CAUSÉES PAR UNE
MANIPULATION OU UNE INSTALLATION INCORRECTE DU PRODUIT. CES INSTRUCTIONS DOIVENT ÊTRE RESPECTÉES
POUR UNE INSTALLATION SÛRE.
LIRE LES INSTRUCTIONS AVANT DE DÉBALLER LE PRODUIT
2 PERSONNES SONT NÉCESSAIRES POUR SOULEVER
ET PENDANT TOUTE L’INSTALLATION DE CE PRODUIT
ATTENTION ! ASCENSEUR POUR DEUX
PERSONNES REQUIS
Instrucons d’installaon pour la plongée froide en bois

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1.Pré-exécuon
Avant l’installaon
① Votre refroidisseur peut ne pas inclure le réfrigérant en raison de la réglementaon de sécurité du transport, lorsque
vous obtenez le produit, veuillez vérifier si le refroidisseur est livré avec du réfrigérant ou non, l’unité fonconnant sans
réfrigérant peut facilement endommager la machine et arrêter de fonconner!
② S’assurer que la tension de la prise murale correspond à la tension nominale du refroidisseur.
③ L’interrupteur d’alimentaon doit être réglé à une hauteur d’au moins 4'6"/1,4 m du sol ou au-dessus de la hauteur
que les enfants ne peuvent pas aeindre.
En usage
① Ne pas allumer le plongeon froid sans eau d’irrigaon! Empêcher la pompe de tourner au ralen et de brûler.
② Gardez l’air circulant en douceur autour de la machine et le trou de venlaon thermique ne doit pas être bloqué par des
obstacles.
Après usage
① S’il vous plaît couvrir le plongeon froid pour empêcher les débris tels que le sable du vent et les feuilles de floer dans la
baignoire qui pourrait causer un blocage de l’eau après ulisaon.
② Lorsque la température ambiante est inférieure à 32 °F (y compris 32 °F), l’eau de l’échangeur de chaleur et du réservoir
d’eau gèle, ce qui provoque des fissures. Si le plongeur froid n’a pas été allumé pendant une longue période ou n’a pas été
ulisé, vidangez l’eau.
2.Règlements de sécurité
① La baignoire doit être installée et ulisée conformément au présent manuel d’ulisaon.
② Les enfants de moins de 12 ans doivent être sous la surveillance d’un adulte à uliser et ne pas jouer avec l’appareil pour
prévenir le danger.
③ Ne jamais uliser la baignoire en état d’ébriété, après avoir pris des repas ou des boissons alcoolisées. La consommaon
de boissons alcoolisées avant ou pendant le bain provoque de la somnolence et peut entraîner une hypothermie, une
perte de conscience ou même la noyade.
④ NE PAS insérer d’objets tels que des doigts ou des bâtons dans l’élément du refroidisseur pour éviter tout danger.
⑤ NE PAS uliser le sèche-cheveux, les lumières, le téléphone, la télévision, la radio ou d’autres appareils électriques à
moins de 5 pieds de la baignoire.
⑥ NE PAS trop remplir la baignoire avant d’entrer dans l’eau. Le remplissage peut entraîner des déversements et des
condions glissantes lorsque vous entrez dans la baignoire. Soyez extrêmement prudent lorsque vous entrez et sortez.
⑦ Les personnes qui prennent des médicaments ou qui ont des antécédents médicaux défavorables doivent consulter un
médecin avant d’uliser la baignoire pour éviter une hypothermie et une possible noyade.
⑧ Il est contre-indiqué pour les personnes souffrant d’érosion cutanée ou de plaies non cicatrisées après la chirurgie.
⑨ Une température de l’eau supérieure à 100 °F peut causer de l’hypothermie ou d’autres problèmes de santé. Vérifiez la
température de l’eau et ajustez-la en foncon de votre confort personnel.
⑩ Les fiches de cordon d’alimentaon, les prises et les interrupteurs de l’équipement doivent être situés dans des endroits
hors de portée des enfants et doivent être protégés de la pluie pour éviter tout danger.

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3.Informaons sur le produit
Nom du produit : Plongeon à froid en bois
Modèle : WIC71-A
Taille : 71.8 x 47.7 x 24.6
Capacité : 1 personne
Matériau : Bois en caoutchouc thermo + doublure en acier inoxydable
24-5/8 po
47-3/4 po
58-1/4 po
69-1/2 po
26-7/8 po
71-7/8 po
1-5/8 po
VUE DE CÔTÉ
VUE DE CÔTÉ
REFROIDISSEUR
VUE INTÉRIEURE
VIDANGER
DOSSIER

R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
R
WOODBRIDGE
www.woodbridgebath.com
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Prise de courant
Refroidisseur
Sore
Entrée
Remplisseur
Sore
Entrée
Glacière
Schéma de principe
Modèle de mise à niveau
Système O3
Système de filtraon
Principe de fonconnement
La pompe à eau du refroidisseur pompe l’eau de la baignoire, refroidit la température de l’eau à travers le système de r
efroidissement, puis restue l’eau de refroidissement à basse température à la baignoire.
Le refroidisseur chauffe l’eau dans l’unité, de sorte que la température de l’eau augmente, puis restue l’eau à la baignoire
pour obtenir l’effet du chauffage.
La vue de police de l’affichage
Table of contents
Languages:
Popular Hot Tub manuals by other brands

Weslo
Weslo DayBreak510 user manual

Balboa
Balboa ML551 Quick reference guide

KIRAMI
KIRAMI Original Woody Instructions for use

Penner Bathing Spas
Penner Bathing Spas 770010-1 Operation & maintenance manual

SCS
SCS BALBOA 501 Operating procedure

Jacuzzi
Jacuzzi J-SS40 Salt System Installation and operating instructions