manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Worthington
  6. •
  7. Water Heater
  8. •
  9. Worthington AMTROL DIATROL 537 Installation instructions

Worthington AMTROL DIATROL 537 Installation instructions

This manual suits for next models

1

Other Worthington Water Heater manuals

Worthington Amtrol ASME CWBT Series Installation instructions

Worthington

Worthington Amtrol ASME CWBT Series Installation instructions

Worthington Amtrol EXTROL LBC Series User manual

Worthington

Worthington Amtrol EXTROL LBC Series User manual

Popular Water Heater manuals by other brands

clage German pool CEX13 operating instructions

clage

clage German pool CEX13 operating instructions

Noritz proTough NR98SV installation manual

Noritz

Noritz proTough NR98SV installation manual

DeDietrich KALIKO TWH 200 EV Installation and service manual

DeDietrich

DeDietrich KALIKO TWH 200 EV Installation and service manual

veito FLOW Installation and operating instructions

veito

veito FLOW Installation and operating instructions

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

ICI Caldaie

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

Savio Laser 11 A Instruction manual for installation and use

Savio

Savio Laser 11 A Instruction manual for installation and use

Kenmore 153.582400 Use & care guide

Kenmore

Kenmore 153.582400 Use & care guide

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

clage E-Mini Series Operating and installation instructions

clage

clage E-Mini Series Operating and installation instructions

Solar SunX 317365-002 instruction manual

Solar

Solar SunX 317365-002 instruction manual

Bradford White EF Series Service manual

Bradford White

Bradford White EF Series Service manual

Dimplex ECSd125-580 Installation and user instructions

Dimplex

Dimplex ECSd125-580 Installation and user instructions

Dux 32FCR6N installation manual

Dux

Dux 32FCR6N installation manual

Noritz N-132M Owner's guide and installation manual

Noritz

Noritz N-132M Owner's guide and installation manual

TESY GCV7/4S 10047 Instructions for use and maintenance

TESY

TESY GCV7/4S 10047 Instructions for use and maintenance

A.O. Smith Gphe 50 instruction manual

A.O. Smith

A.O. Smith Gphe 50 instruction manual

Rinnai REP199i Installation and operation manual

Rinnai

Rinnai REP199i Installation and operation manual

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

Toyotomi

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Models 537 through 541
DIATROL®
SHOCK SUPPRESSORS FOR POTABLE WATER
INSTALLATION & OPERATION INSTRUCTIONS
READ CAREFULLY THE PRODUCT
INSTALLATION & OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN
THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/
OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT
WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES,
FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
EEXPLOSION OR RUPTURE HAZARD A relief
valve must be installed to prevent pressure in
excess of local code requirement or maximum working pressure
designated in the Product Manual, whichever is less. Do not expose
Product to freezing temperatures or temperatures in excess of 200° F.
Do not adjust the pre-charge or re-pressure this Product except for any
adjustments required at the time of initial installation, especially if
Product corroded, damaged or with diminished integrity. Adjustments to
pre-charge must be done at ambient temperature only. Failure to
properly size the Product or follow these instructions may result in
excessive strain on the system lead to Product failure, serious or fatal
personal injury, leakage and/or property damage.
Use only lead-free solder and flux for all sweat-
solder connections, as required by state and
federal codes.
Chlorine & Aggressive Water: The water quality
can significantly influence the life of this Product.
You should test for corrosive elements, acidity, total solids and other
relevant contaminants, including chlorine and treat your water
appropriately to insure satisfactory performance and prevent premature
failure.
Install or store where Product will not be exposed
to temperatures below freezing or above 100°F,
do not expose to any type of weather. Water freezing in the system will
break it. Do not attempt to treat water over 100°F. Do not install in direct
sun light. Excessive sun heat may cause distortion or other damage to
non-metallic parts.
This Product, like most Products under pressure,
may over time corrode, weaken and burst or
explode, causing serious or fatal injury, leaking or flooding and/or
property damage. To minimize risk, a licensed professional must install
and periodically inspect and service the Product. A drip pan connected
to an adequate drain must be installed if leaking or flooding could cause
property damage. Do not locate in an area where leakage of the tank or
connections could cause property damage to the area adjacent to the
appliance or to lower floors of the structure.
This product can expose you to chemicals
including lead, which is known to the State of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal
injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a licensed professional immediately. Current
copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS.
OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS
PROPERTY DAMAGE.
© 2019 Worthington Industries Inc. Part #: 9015-199 (01/19)
One or more features of this product are covered by U.S. patents, visit www.amtrol.com/patents for more information.
1400 Division Road, West Warwick, RI USA 02893
T: 800.426.8765 www.amtrol.com
1. LOCATION:
 InstalltheDiatrolonthesupplypipingascloseas
possibletotheoffendingfixture(s).TheDiatrolshould
beinstalledupstreamofanyfast-actingvalves.Use
theguidelinesbelowtodeterminethebestplace-
ment.Multiplefixturesandlongsupplylinesmay
requiretheinstallationofmultipleDiatrolshocksup-
pressors.
A. Onbranchlinesupto20’long.
B. Onbranchlinesover20’long.
2. POSITION:
The Diatrol will function in any position. Ensure the
nearby piping is supported adequately.
3. ADJUSTMENT
With the Diatrol empty of water, adjust the factory
pre-charge to equal the average flow pressure. For
example: if the line pressure registers 65 psig with the
fixtures open, adjust the Diatrol air charge to 65 psig.
4. MAINTENANCE
A licensed professional should check the complete
system, including the Diatrol, yearly and more
frequently as the system ages.
WARRANTY
Five (5) Year Limited Warranty
Visit www.amtrol.com for complete warranty details.
FIXTURE
Up to 20 ft.
FIXTURE FIXTURE FIXTURE FIXTURE
More than 20 ft.
FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE FIXTURE
Install first Diatrol®
half distance between
first and last fixture.
Install second Diatrol®
between last two fixtures.
Diatrol®
PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY
IMPORTANT GENERAL SAFETY INFORMATION -
ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.