Xeline MM-202BX User manual

MM-202BX
Installation Manual
PLC Master Unit
Plug into the future
Powerline Communication by Xeline
Xeline Co., Ltd.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
2
ATTENTION
This equipment conforms with the following CE standard(s):
(1) EN55022
(2) EN60950-1
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
◎ Reorient or relocate the receiving antenna.
◎ Increase the separation between the equipment and receiver.
◎ Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
◎ Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user's authority
to operated the equipment under FCC rules.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
3
Table of Contents
1. Introduction ····························································································· 5
2. Before Installing the MM-202BX······································································· 6
2.1 Package Contents··················································································· 6
2.2 Installation Environment ·········································································· 6
2.3 Guidelines for Installation········································································· 7
2.4 Safety Precautions ················································································· 7
3. Getting to Know the MM-202BX······································································· 8
3.1 Front View··························································································· 8
3.2 Top View····························································································· 8
3.3 Bottom View ························································································ 8
3.4 Product Specifications ············································································· 9
4. Installing the MM-202BX ··············································································10
4.1 Connecting the Power ············································································10
4.2 Configuring the MM-202BX ·······································································10
4.3 Connecting the CU-100A to the MM-202BX ·····················································10
4.4 Connecting the MM-202BX to the ISP Backbone ···············································11
4.5 Checking the Final Connections ·································································11
4.6 Resetting to Factory Default Mode······························································12
5. Trouble Shooting·······················································································13
6. Appendix································································································14

MM-202BX Installation Manual
This documentis subject to change without prior notice.
4
Figure Index
Figure 1 XPAS-200B PLC Internet Access System Configuration??! ???? ???
??? ??┞┺.
Figure 2 MM-202BX Package Contents ........................................................ 6
Figure 3 MM-202BX Front View................................................................ 8
Figure 4 MM-202BX Top View .................................................................. 8
Figure 5 MM-202BX Bottom View.............................................................. 9
Figure 6 Connecting the MM-202BX to the CU-100A.......................................10
Figure 7 Connecting the MM-202BX to the ISP backbone .................................11

MM-202BX Installation Manual
This documentis subject to change without prior notice.
5
1.Introduction
Powerline Communication (PLC) technology uses the existing powerline infrastructure to
transfer high-speed data, eliminating the need for expensive and complicated cable
installation. Because the home or office is already a ‘wired network’ through powerlines,
Xeline’s PLC system offers a cost-effective and easy-to-install Internet access solution from
any electrical outlet.
Xeline's XPAS-200B PLC Internet Access System supports data rates of up to 24Mbps and is
targeted for effective Internet access over powerlines in residential houses or high-rise
building configurations.
The XPAS-200B system supports both Master/Slave or Ad-hoc topology and is based on Xeline's
proprietary Cell-structured MAC (CMAC), which offers virtually unlimited number of nodes per
physical network.
Remote configuration and firmware upgrade are also supported for efficient setup and
maintenance of the PLC units in mass-usage environments.
Xeline's XPAS-200B system supports EMS (Element Management System) for effective remote
monitoring and management of the PLC networks.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
6
2. Before Installing the MM-202BX
2.1 Package Contents
Before installing, first verify that you have all of the following items.
○MM-202BX PLC Master Unit
○1 AC power cable ○1Installation manual ○1 RJ-45 cable (CAT 5)
Figure 1MM-202BX Package Contents
If there is a missing item or any visible damage, notify your service provider or dealer
immediately.
2.2 Installation Environment
In order to install the MM-202BX, the following conditions must be met:
(1) Power supply for the MM-202BX
(2) Convenient access to the local backbone network
(3) Sufficient space to install the MM-202BX and CU-100A (PLC Coupler)
Note: In indoor configurations, one of the optimal locations for the MM-202BX is
near the distribution station.
(4) 1 Laptop PC 1
(5) RJ-45 direct cable (Core manufactured by: E-Tech Electronics Co., Ltd.Model No. cu1330b)
(6) 1 SU-200BX(test unit) to check the PLC connection with the MM-202BX
(7) 1 Switch Hub for connecting multiple MM-202BX and EU-200BX units (optional)

MM-202BX Installation Manual
This documentis subject to change without prior notice.
7
2.3 Guidelines for Installation
Please make sure to read the following guidelines before installation.
(1) Install the MM-202BX on the inner side of power-supplied distribution panel of a
building. In case there is not enough space to install inside, install it on the
external wall of the distribution panel.
(2) When installing on the external wall of the distribution panel, prepare a
protective enclosure to protect the device and to prevent effects from external
environment.
(3) Never install MM-202BX on a wall made of materials such as aged and rusted
wood, etc.
(4) Use silicon compound to fix firmly when it is difficult to use only clamp screws
when fixing the MM-202BX on the inner wall of the distribution panel.
(5) Avoid the following environments:
-Areas with extremely high or low temperatures
-Areas with high humidity or high risk of flooding
-Areas where sudden changes in temperature occur
-Under direct sunlight
(In outdoor configurations, install the MM-202BX in a shady area away from
direct sunlight.)
(6) Install the MM-202BX at least 1m from the ground to avoid contact with children
or small animals.
2.4Safety Precautions
Please make sure to read the following instructions before handling the equipment.
(1) Read all instructions before installing or operating the equipment. Be sure to
keep this manual for further reference.
(2) Please follow all the safety precautions and other installation procedures.
(3) Do not place heavy objects on top of the MM-202BX.
(4) If water or any other liquid is spilled on the device, turn off the power and
unplug the cord. Contact your Internet Service Provider or Xeline’s Technical
Support Center. Continuing to use the device may cause fire or an electric shock.
(5) Do not open, disassemble, or attempt to repair the device. If service or repair is
required, contact your service provider or Xeline’s Technical Support Center.
Incorrect reassembly can cause electric shock when the equipment is
subsequently used.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
8
3. Getting to Know the MM-202BX
3.1 Front View
Figure 2MM-202BX Front View
3.2 Top View
Figure 3MM-202BX Top View
UPLINK Activates when the MM-202BX’s UPLINK port is connected to the Backbone.
Blinks during data transmission between the MM-202BX and backbone.
ACT1 (PCS) Blinks when PLC signals are detected.
ACT2 (LINK) Blinks when the detected PLC signals are valid.
PWR Activates when power is turned on.
UPLINK RJ-45 Ethernet port (WAN port)
EXT RJ-45 Ethernet port (LAN port 1)
LAN RJ-45 port for UART signal (optional use)
SIG1 RJ-11 port for connection to CU-100A PLC Coupler
SIG2 RJ-11 port for connection to CU-100A PLC Coupler
RESET Resets the MM-202BX to factory default mode. (Caution!)
Reset button (inside 5th hole from left)

MM-202BX Installation Manual
This documentis subject to change without prior notice.
9
3.3 Bottom View
Figure 4MM-202BX Bottom View
3.4Product Specifications
Specifications Remarks
Data rates Up to 24Mbps
RJ-45 Ethernet 2port For connection with backbone
RJ-45 UART 1 port Optional use
Interface
RJ-11 PLC 2port For connection with CU-100A
Power AC 110V -240V, 0.5A, 50/60Hz
Dimensions 260mm ×154mm ×35mm (W x D x H)
Weight 505g
operational
temperature
40 ºC
Power Switch Switch for turning power ON/OFF
AC Inlet For connection to power cable.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
10
4. Installing the MM-202BX
4.1 Connecting the Power
Plug the power cable of the MM-202BX into an available power outlet in the distribution
station or panel1.
4.2Configuring the MM-202BX
The MM-202BX is remotely configured by the EU-200BX through automatic process. Therefore
there is no need to manually configure the MM-202BX2.
4.3 Connecting the CU-100A to the MM-202BX
The CU-200A is usually installed near the circuit breaker of each subscriber’s house. Use a
straight RJ-11 cable to connect the MM-202BX and CU-100A. The RJ-11 cable is not included
with the MM-202BX3.
①Insert one end of the RJ-11 cable in the SIG1 or SIG2port of the MM-202BX.
②Insert the other end of the cable in the INPUT port of the CU-100A.
Figure 5Connecting the MM-202BX to the CU-100A
1If there is no available power outlet, connect the Hot line and Neutral line from the public
power supply in order to provide power to the MM-202BX. Be careful not to use private
powerlines.
2Please refer to the EU-200BXInstallation Guide for more details.
3The RJ-11 cable is not included with the product because the distance to each subscriber’s
house varies widely according to the site configuration. The RJ-11 cable should be a straight
cable with wires in the same sequence on both ends.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
11
4.4 Connecting the MM-202BX to the ISP Backbone
Note: To connect multiple MM-202BX units and the EU-200BX EMS unit, it is recommended to
prepare a Switch Hub in advance for installation.
①Check the connection between the backbone and Switch Hub.
②Connect the UPLINK port of the MM-202BX to the Switch Hub using the RJ-45 cable.
Figure 6Connecting the MM-202BX to the ISP backbone
③Once the MM-202BX is connected to the backbone, turn on the power of the MM-
202BX.
④Wait approximately 3minutesfor the EU-200BXto finish the remote registration
process.
4.5Checking the Final Connections
Note:When using the SU-200BX test unit, make sure it is set to Factory Default mode.4
4.5.1 Checking the Ethernet connection
①Connect the laptop PC to the LAN port of the MM-202BX using a RJ-45 cable.
②Configure the network properties of the laptop PC as provided by the ISP.
③Confirm if the Internet connection is working properly.
4.5.2 Checking the PLC connection using the SU-200BX test unit
①Turn off the power of the MM-202BX.
②Disconnect ALL cables (including the RJ-11 cable)from the MM-202BX except for the
4Please refer to the SU-200BX Installation Guide for details on resetting to Factory Default
mode.The ACT LED of the SU-200BX will blink when successfully changed to the factory
default mode.
MM-202BX

MM-202BX Installation Manual
This documentis subject to change without prior notice.
12
power cable.
③Connect the SU-200BX test unit to the MM-202BX UPLINK port using a RJ-45 cable.
④Connect the SU-200BX power cable to a power outlet from the same phase as the
installed MM-202BX.
⑤Turn on the power of the MM-202BX.
⑥Using a long sharp instrument, push down on the reset button of the SU-200BX to.
⑦Turn on the power of the SU-200BX while the reset button is pushed down.
⑧Check if the ACT LED is blinking.
⑨Disconnect the RJ-45 cable from the SU-200BX and MM-202BX.
⑩Reconnect the MM-202BX cables to their original positions.
⑪Reset the power of the SU-200BX.
⑫Connect the laptop PC to the LAN port of the SU-200BX and configure the network
properties.
⑬Confirm if the Internet connection is working properly.
4.6 Resetting to Factory Default Mode
Use the reset button at the top side of the MM-202BXin order to reset the configuration into
factory default mode.
①Turn off the power of the MM-202BX.
②Disconnect all cables (including CU-100A cables) from the MM-202BX except for the
power cable.
③Use a long sharp instrument (such as a tweezers) in order to push down on the reset
button on the top side of the MM-202BX.
④Turn on the MM-202BX while pushing down on the reset button.
⑤Using the sharp instrument, push down on the reset button for 1 second. Wait at
least 1 second before repeating the procedure at least 3 times or more.
⑥The ACT 2 LED will blink when the MM-202BX is changed to the factory default mode.
⑦Reset the power of the MM-202BX.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
13
5.Trouble Shooting
Power
Problem Checklist
The PWR LED does not
activate.
①Check if the power cable is firmly plugged into the MM-
202BX and power outlet.
②Check if the Hot line and Neutral line is correctly
connected to the power outlet.
Ethernet Connection
Problem Checklist
The UPLINK LED does not
activate.
①Check if the RJ-45 cable is firmly plugged into the UPLINK
port of the MM-202BX and the Switch Hub.
②Check if the Switch Hub is operating normally.
The network connection
icon in the PC icon tray is
disabled.
①Check if the RJ-45 cable is firmly plugged into the LAN
port of the MM-202BX and NIC of the laptop PC.
②Check if the NIC connection is disabled in the Local Area
Network window.
Internet access is not
possible.
①Try connecting the laptop PC directly to the Switch Hub
and recheck the Internet accessibility.
②Check the IP configuration of the laptop PC. If the IP
configuration is correct, the problem lies in the ISP
backbone.
PLC Connection
Problem Checklist
The ACT1and ACT2 LEDs
of the MM-202BX do not
activate.
①Check if the RJ-11 cable is firmly plugged into the SIG2
port of the MM-202BX and the INPUT port of the CU-100A.
②Check the coupling procedures of the CU-100A are
correctly done. For details concerning the coupling
methods, refer to the CU-100A Installation Guide.
③Check if the SU-200BX test unit is plugged into an outlet
that is from the same phase as the powerlines coupled to
the CU-100A. (This procedure is not necessary if multi-
phase coupling method is used.)
Internet access is not
possible.
This can occur when the SU-200BX test unit configuration has
not been correctly downloaded. Reset the SU-200BX to the
factory default mode and download the configuration again.
If the problem is still not solved, please contact Xeline’s Technical Support Center.

MM-202BX Installation Manual
This documentis subject to change without prior notice.
14
6. Appendix
lCopyright 2005Xeline Co., Ltd. All rights reserved.
All Xeline brand product names are trademarks of Xeline Co., Ltd.
Other product and company names mentioned herein are the trademarks of their
respective owners.
lInformation in this document is subject to change without notice. No part of this document
may be reproduced or altered in any form or by any means, electronical or mechanical,
for any purpose, without the express written permission of Xeline Co., Ltd.
lXeline Technical Support Center
Address: 5F. Seowon Bldg. 1515-4,
Seocho3-dong, Seocho-gu,
Seoul 137-871, Republic of Korea
Telephone: +82 2 598 0980
Facsimile: +82 2 598 0975
Website: http://www.xeline.com
Table of contents