Xinje DP-7022P User manual

DP-7022P step driver
Users manual
WUXI XINJE ELECTRIC CO., LTD.
NO. DC14 20120224 1.0


DP-7022P Users Manual
1
Content
1. Summary.................................................................................................................2
1-1. Features..............................................................................................................................2
1-2. Application.........................................................................................................................2
1-3. Electrical features ..............................................................................................................2
2. Operation Guide......................................................................................................3
2-1. Safety.................................................................................................................................3
2-2. Attention ............................................................................................................................3
2-3. Installation .........................................................................................................................3
3. Interface and function .............................................................................................4
3-1. Control signal interface......................................................................................................4
3-1-1. Function..................................................................................................................4
3-1-2. Sequence chart of control signals...........................................................................4
3-1-3. Input circuit ............................................................................................................5
3-2. Power terminals .................................................................................................................6
3-2-1. Function..................................................................................................................6
3-2-2. Power supply requirements ....................................................................................6
3-2-3. Wiring.....................................................................................................................6
3-3. Mode setting ......................................................................................................................7
3-3-1. Current setting........................................................................................................7
3-3-2. Subdivision setting .................................................................................................7
4. Panel Operation..........................................................................................................8
4-1.Basic operation ................................................................................................................8
4-1-1.Panel function.......................................................................................................8
4-1-2.Switch between basic status .................................................................................8
4-2.Parameter setting..............................................................................................................9
4-3.Monitor status................................................................................................................11
4-4.Auxiliary function operation..........................................................................................11
4-4-1.System information ............................................................................................11
4-4-2.Alarm information..............................................................................................12
4-4-3.Recover to factory parameters............................................................................12
4-4-4.External monitor.................................................................................................13
4-4-5.Force enabled......................................................................................................13
4-5.Fault alarm operation.....................................................................................................13
5. Dimension, Installation and Wiring......................................................................15
5-1. Dimension........................................................................................................................15
5-2. Installation .......................................................................................................................15
5-3. Typical Wiring .................................................................................................................16
6.Problem and solution ................................................................................................17
7. Motor Selection........................................................................................................18

2
1. Summary
DP-7022P subdivision stepper driver, 220VAC input voltage, 7.0A output current,
can apply to all kinds of three-phase hybrid stepper motor with rated current below
7.0A. It is based on digital control and sine wave current control technology, which
makes the motor run smoothly with low noise and little interference. So this type
product is especially suitable for high resolution equipments, such as laser marking
machine, CNC machine etc.
1-1. Features
Digital control technology, high anti-interference capacity
Low noise on motor running
Power supply up to 220VAC
Effective value of current up to 7.0A
Dynamic and selectable subdivision
Optically isolated input signal
Current set easy, any level selectable
Over-voltage and over-current protection
Built-in braking resistor
1-2.Application
DP-7022P can apply to all kinds of medium and small automatic devices and
instruments, such as aerodynamic marking machine, labeling machine, cutting
machine laser type machine, small carving tool, CNC machine etc., especially having
a perfect performance on the devices with the requirement of low noise and vibration
with high precision and speed.
1-3. Electrical features
Item
Min
Typical
Max
Power supply(VDC)
200
220
240
Output current virtual value(A)
0
-
7.0
Logical input current(mA)
4
7
16
Stepper pulse frequency(KHz)
0
-
200
Insulation resistor(MΩ)
500
-
-
Ambient temperature
0℃~50℃
Max working temperature
60℃
Humidity
40%~90% RH(no condensation)
Vibration
5.9m/s2 Max
Storage temperature
-20℃~65℃

DP-7022P Users Manual
3
2. Operation Guide
Please read the following suggestion carefully before you install the driver.
2-1. Safety
The driver is authorized to be installed and operated by the professional staff.
Don’t turn on the power before connecting to the motor.
Make sure that the input signal meets the technical requirements.
Don’t make the setting or measure operations on the motor and driver during
power on.
Please do the wiring, installation and parameter setting after power is off for more
than 3 minutes.
Ensure the connection operation is absolutely correct and fixable before you turn
on the power, including the power wire, motor cable and signal cable.
Avoid electromagnetic interference.
2-2. Attention
Please use shield cable for signal input, and leave each other for distance. The
further the distance, the better the interference is avoided.
Please connect the motor cover to the GND terminal.
Don’t operate the output terminal when power on, otherwise the driver will be
damaged.
2-3. Installation
Don’t install the driver next to the heat source.
Don’t expose the driver to the dusty, corrosive gas, moist environment, and work
in low vibration place.
For perfect conducting, please ensure the fixation between earth wire of host
computer, driver, motor and ground.

4
3. Interface and function
POWER
CHARGE
STA/ESC INC DEC ENTER
U
V
W
PE
L
N
PE
P+
PB
CAUTION!
·Make sure the
connection is
·Don't touch
the terminals
when running.
correct before
power on.
3-1. Control signal interface
3-1-1. Function
Signal
Function
Explanation
A
Communication
terminal
RS485 communication ; A: RS485+, B:RS485-
B
PUL+
Pulse signal
The motor moves one step at the rising edge of the signal. PUL-
high voltage 4~5V, low voltage 0~0.5V.
PUL-
DIR+
Direction signal
High/low voltage effective. Change the direction of the motor, the
original direction of the motor is decided by the wiring,
exchanging any phase can change the motor direction.
DIR-
ENA+
Enable signal
To release the motor. When ENA+connects to 5V and ENA-
connects to low voltage, the driver will cut all phase current and
be in free state, stepper pulse will not be responded. Please let the
terminals vacant if out of use.
ENA-
ERRO
Error signal
Output over-voltage, over-current signal.
COM
3-1-2. Sequence chart of control signals
In order to ensure the system response reliability, the control signals should meet the
following requirements:
The signal effective high voltage is 24V; effective low voltage is less than 0.5V.
ENA (enable signal) should change to low voltage 3μs before DIR (direction
signal).

DP-7022P Users Manual
5
Build the DIR (direction signal) 5μs before the PUL (pulse signal) falling edge.
Pulse width should be more than 1.2μs.
Pulse low voltage duration should be more than 1.2μs.
Sequence chart:
3-1-3. Input circuit
Common positive connection of input circuit:

6
Input requirements:
All the input signals go through the photo-electric isolation please provide at least
8mA control signal to ensure the conduction of built-in high-speed optical
coupler.
The photo-electric has installed current limiting resistor, all the control signals
connect to +24V.
3-2. Power terminals
3-2-1. Function
Interface
Function
Explanation
U
Motor phase U
Motor phase U input
V
Motor phase V
Motor phase V input
W
Motor phase W
Motor phase W input
PE
Ground
Power supply ground
L、N
Power supply
Power supply input, 200~240VAC
PE
Ground
Power supply ground
P+、PB
Braking resistor
Braking resistor terminal
3-2-2. Power supply requirements
To keep the normal working of drive, please ensure the power supply in the range
of 200~240VAC.
3-2-3. Wiring
W
PE
L
N
PE
P+
PB
AC200-240
U
V
Notes:
The power supply voltage of driver determines the motor high speed performance (the
larger the voltage, the higher the high-speed torque, can avoid loss of synchronism),
set current determines the motor output torque (the bigger the current, the higher the
output torque).

DP-7022P Users Manual
7
However, when the power supply voltage is large, the vibration is large at low-speed;
if set current is large, the driver and motor heat is very serious.
For actual applications, users can select suitable current to achieve well effect.
3-3. Mode setting
The driver set the subdivision and current by parameters through panel. For more
details, please refer to chapter 4-2.
3-3-1. Current setting
Parameter P0.00 can set any current level in the range of 0~7.0A. Parameter
P0.01can set the half current and full current state.
3-3-2. Subdivision setting
Parameter P0.02 can set the subdivision resolution. For more details, please refer
to chapter 4-2.

8
4. Panel Operation
This chapter mainly introduces the operation of digital manipulator and its
application. The digital manipulator can set parameters and run the motor. We suggset
users use the digital manipulator when reading this chapter.
4-1.Basic operation
This section mainly introduces some basic operation about how to set running
condition.
4-1-1.Panel function
The panel can set parameters, such as display, run and status.
4 bit digital display: display status and parameters of driver, alerting signal.
POWER indicator: lights when control circuit power on
CHARGE indicator: lights when main circuit power on. As main circuit
capacitor remains charge after cutting off the power, the capacitor still shine
and do not touch driver wiring at this time.
Take the initial status of the panel as example:
Key
Function
STA|ESC
Short press: status switch, status return
INC
Short press: increase displaying data; Long press: increase
displaying data continuously
DEC
Short press: decrease displaying data; Long press: decrease
displaying data continuously
ENTER
Short press: shift bit; Long press: enter data set and check
4-1-2.Switch between basic status
Basic status includes display status, monitor status, auxiliary function status,
parameter set status and alarm status (visible only when error occurs). After clicking
STA|ESC, the following statuses switch in proper order:
STA|ESC
INC
DEC
ENTER
CHARGE
POWER

DP-7022P Users Manual
9
Display method:
Set parameters status PX.XX: the first X represents group number, the latter
two X represent parameter number in this group;
Monitor status U-XX: XX represent monitor parameter number;
Auxiliary function status FX.XX: the first X represents group number, the
latter two X represent parameter number in this group;
Alarm status E-XX: XX represents alarm number.
Run status:
Driver is closed
Driver is in enabled OFF status (panel force
enable OFF)
Running
Driver is in enabled ON status
4-2.Parameter setting
We can select and adjust function by setting parameter. Table 1 is the parameter
information.
Modbus address: 0x000~0x005
Table 1 Driver parameters
P0
Name
Unit
Factory
value
Range
Note
P0.00
Set phase
current(effective value)
0.1A
10
0~70
P0.01
Half current enable
0
0~1
0: half current 1 full current
P0.02
Pulse quantity per cycle
16
2~655
Actual value= set value×100
P0.03
Modbus number
1
1~255
P0.04
Serial port parameters
2206
0~2209
See table 2
P0.05
Select built-in/out pulse
0
0~1
0: outside pulse
1: built-in pulse
Auxiliary function status
Monitor status
Parameter status
Run status
Power ON

10
Table 2 Serial Port Parameters
Function
Factory value
Range
P0.04.0
Baud rate
6
0~9
0:300
1:600
2:1200
3:2400
4:4800
5:9600
6:19200
7:38400
8:57600
9:115200
P0.04.1
Data bit
0
0:8
P0.04.2
Stop bit
2
0:2 bit
2:1 bit
P0.04.3
Parity bit
2
0~2
0: none
1: odd parity
2: even parity
Parameter modification steps:
The parameter schedule contains the modification range.
The following are the steps about how to change value in P0.02 from 16 to 32:
1. Press STA|ESC key and switch the status to parameter status, and press
‘ENTER’ to enter this status.
2. The second digital tube from the left side will shine, and short press ‘ENTER’
key to confirm; then the right two digital tubes will shine, and press INC, DEC or
‘ENTER’ key to select number 2, and long press ‘ENTER’ to confirm.
3. Then, data in P0.02 will be displayed, and the lowest bit ‘0’ shines, short press
ENTER, its left bit shines. Press INC, DEC or ENTER and change the value to 32,
long press ENTER to confirm the modification.
So far, user parameter in P0.02 has changed from 16 to 32.
If you want to change the parameter again, just repeat the step 2 and 3.
4. Press STA|ESC key to return to other status.

DP-7022P Users Manual
11
4-3.Monitor status
The function can realize step driver’s instruction value and inside status monitor.
Even though the motor is running, we can change the monitor status.
The method to use monitor status
Take the monitor code U-01 for example:
1. Press STA|ESC to switch to monitor status.
2. Press INC or DEC, and select the code U-01 you want to monitor, and then
long press ENTER.
3. It will display the data in U-01, the module temperature.
4. Press INC/DEC key, monitor code will increase/decrease 1.
5. Press STA|ESC to switch monitor number.
Content of monitor status
Monitor
code
Content
Unit
U-00
Monitor speed
rpm
U-01
Module temperature
0.1°
U-02
Busbar voltage
V
U-03
Coil current
0.1A
4-4.Auxiliary function operation
Under auxiliary function status, we can operate by panel.
Function
code
Content
F0.**
System information,including inforamtion number and data
F1.**
Alarm information, including alarm code and motor status when
alarming
F2.00
Recover to factory parameters
F3.00
Extenal communication monitor
F4.00
Force to enable
4-4-1.System information
Press STA|ESC to switch to auxiliary function status, set group number 0 to enter
system information. Then use INC/DEC key to change information code and long
press ENTER to see the corresponding information. Press STA/ESC back.
Information code and description:

12
Function
code
Description
Function
code
Description
F0.00
Driver serial number
F0.01
Type
F0.02
Data of production: year
F0.03
Data of production: month, day
F0.04
Data of production: day
F0.05
Software version
F0.06
Hardware version
4-4-2.Alarm information
Under auxiliary function status, set group number 1 to check alarm information.
The following are the steps:
1. Press STA|ESC to select auxiliary function status.
2. Press INC/DEC, set group number 1, short press ENTER to confirm.
3. Press INC, DEC or ENTER to change information code.
4. Press ENTER, you can see the corresponding alarm information.
Function
code
Content
unit
Modbus
address
F1.00
Current alarm code ※1
0x0305
F1.01
Current warning code ※2
0x0306
F1.02
Alarm/warning code 1 when alarming
0x0307
F1.03
U phase current when alarming
A
0x0308
F1.04
V phase current when alarming
A
0x0309
F1.05
Effective current when alarming
A
0x030A
F1.06
DC busbar voltage when alarming
V
0x030B
F1.07
Module temperature
℃
0x030C
F1.08
Motor speed when alarming
rpm
0x030D
F1.09
Alarm/warning code 2 when alarming
0x030E
F1.10
Alarm/warning code 3 when alarming
0x030F
F1.11
Alarm/warning code 4 when alarming
0x0310
F1.12
Alarm/warning code 5 when alarming
0x0311
F1.13
Alarm/warning code 6 when alarming
0x0312
F1.14
Alarm/warning code 7 when alarming
0x0313
※1: when F1.00=0, no alarm status.
※2: when F1.01=0, no warning status.
4-4-3.Recover to factory parameters
Operation Steps:
1. Press STA|ESC to enter auxiliary function status.
2. Press INC or DEC and set the group number 2, and short press ENTER to
confirm.
3. Long press ENTER, ‘0’ will be displayed and shine.
4. Set value 1, and long press ENTER to confirm.
5. Power on again, all parameters will recover to factory value.

DP-7022P Users Manual
13
4-4-4.External monitor
Under auxiliary function status mode, select parameter F3.00. Hint Cout means it
is in external monitor status now and serial port 1 (COM1) works, panel monitor out
of use. Users can debug the driver by host PC.
Press STA or ESC back and quit Cout, recover panel monitor.
4-4-5.Force enabled
Under auxiliary function status, set group number F4.00, long press ENTER to
set F4.00 parameters, meantime modify parameters by INC and DEC key, long press
ENTER to confirm modification.
0: Cancel enabled
1: Force enabled
4-5.Fault alarm operation
When fault occurs, alarm and fault code will jump out automatically; no fault, no
alarm. System fault ‘E-XX’, panel communication default ‘EEEE’. Under alarm
status, part of default alarms can be reset by pressing ENTER.
Note: Please eliminate the alarming reasons at first, then clear the alarm
when alarming.
Alarm information:
Alarm
code
Description
Possible cause
Solution
Note
E-01
Program
damaged
Program self-check do
not pass
Download program again; contact agent
or manufacturer
●
E-02
Paramters
damaged
Parameters self-check do
not pass
Power on again can recover the
parameters to the default value; if
problens repeat, please contact the agent
or manufacturer
●
E-03
Busbar over
voltage
Power voltage too high
Check power voltage and fluctuation
△
E-04
Busbur under
voltage
Power voltage too low
Check power voltage and fluctuation
△
E-05
Module
temperature
too high
Running too long time
with big current leads
to module temperature
too high; environment
temperature too high
Reduce current, enhance ventilation ,
check if the fan is working; lower
ambient temperature
△
E-06
Over current
Motor output by driver
short out; motor fault
Change bad motor, check motor wiring
●
E-07
System
initialization
fail
System chip damaged
Please contact agent or manufacturer
●

14
●Represent the alarm cannot be cleared by panel, only by power off and on.
△Represent the alarm can be cleared by panel after eliminating the default.
Warning information:
Warning code
Content
note
1
Busbar voltage too high
2
Busbar voltage too low
3
Module temperature too high
4
Temperature abnormal
5
Busbar voltage abnormal

DP-7022P Users Manual
15
5. Dimension, Installation and Wiring
5-1. Dimension
POWER
CHARGE
STA/ESC INC DEC ENTER
U
V
W
PE
L
N
PE
P+
PB
CAUTION!
·Make sure the
connection is
·Don't touch
the terminals
when running.
correct before
power on.
5-2. Installation
The driver must be installed in the proper electric cabinet and keep draughty.
Regularly check if the fan works properly. To keep good heat dissipation, please leave
at least 10cm installation space. Do not let the dust or scrap fall into the driver when
installing.
Unit: mm

16
5-3. Typical Wiring
Note:Please separate the power cables (motor and power supply cables) and weak electricity
cable (signal cables) to avoid interference.

DP-7022P Users Manual
17
6.Problem and solution
Problem
Reason
Solution
PWR LED is OFF
Something wrong with the power
supply system
Check the power supply
system
Power supply voltage is low
Increase the power supply
voltage
Motor does not run
Set the current too small
Reset the current
The subdivision is too small
Reset the subdivision
Protection circuit works
Power on again
Release signal is low
Disconnect this signal
Power off
Power on again
Motor wiring is error
Check the motor wiring
No pulse input
Adjust pulse width and voltage
Motor direction is wrong
Motor phase is opposite
Exchange any phase cable
Circuit is cut off
Check the circuit
ALM LED is ON
Motor wiring is wrong
Connect the wire again
Over-voltage or under-voltage
Adjust the voltage
Motor or driver is broken
Check motor and driver
Motor torque is small
Acceleration is too fast
Decrease the acceleration
The motor does not match with the
driver
Change the driver

18
7. Motor Selection
DP-7022P is suitable for 3/6-wire 3-phase hybrid stepper motor. Generally
speaking, select the motor according to the torque and rated current. The torque
depends on the motor dimension. Big dimension motor has big torque. The current
depends on the resistor. Small resistor has large current and the motor will have good
performance at high speed.
For certain wiring motor, the bigger the working current, the larger the output
torque, the serious motor heating. The higher the drive power voltage, the bigger the
motor high-speed torque. The motor high-speed torque is smaller than low-speed
torque.