1. MD-100D/400D Digital RF Modem Main Functions
The MD-100D / 400D digital RF modem has standardized the external appearance and connector
specifications to maintain compatibility with existing analog modems.
It also supports voice call and data communication with DMR transceiver and standard.
When making a voice call, use external microphone and speaker as same as existing digital radio.
It is possible to use transmitter and receiver as a single device when it is used for the village
broadcasting.
In case of data communication, it can be used as a general data modem and it is designed to use AT
COMMAND.
RF Audio/Data Modem
MD-100D VHF
MD-400D UHF

MD-100D / 400D supports dual (analog / digital) mode. It is compatible with existing analog modem or
transceiver. When using digital mode, it is very efficient in data error, clean sound quality and volume,
distance and usage time.
32 channel can be selected by using internal DIP switch.
MD-100D/400D Series main functions are below,
Frequency band - VHF: 150.8~173.4MHz, UHF: 400~470MHz.
1 Zones 32 channel selection (1zone = Max 32 channel) .
Total 32 channels can be set.
RF Power - VHF : 10 Watt, UHF : 5Watt
ETSI Standard DMR Protocol Tier1, 2
Industry Standard AMBE+2 Voice Codec
Dual mode(Digital & Analog)
Add AT Command for user convenience.
3wires continuous mode / 5wires continuous mode
Standard 1Vrms Audio Output (adjustable up to 2.5Vrms).
Carrier Detector
Encryption mode (AES128, 192, 256) - Option
RF Communication Data Speed : 9,600bps
RS-232C communication speed : standard 115,200bps(changed according to program setting)
PC-based modem Control GUI Software for user convenience
Aluminum metal Frame Body
Service Connector : DE-15 Pin Female Connector
Power Supply Voltage : DC +12V
Dimensions : 4.77”(H) x 2.44”(W) x 0.96”(D)
2. Specification
2.1 MD-100D/400D
G
eneral Information
F
requency Range
F
requency Stability
N
umbers of Channel
C
hannel Spacing
D
igital Vocoder
S
ize
W
eight
P
ower
C
urrent Consumption
MD
-100D : 136~174 MHz
MD
-400 : 400 ~470 MHz
±1.5ppm (
-30 to +60℃)
1
Zones / 32 Channels
12.5KHz
AMBE++
110mm(H) x 25mm(W) x 51mm(D)
280
g
DC
+12
Receive Mode
, When using Audio – 350 mA (Audio Max)
T
ransmit Mode – 1,200mA
Standby Mode
– 110mA
R
eceiver Specifications
R
eception Sensitivity
S
quelch Sensitivity
Selectivity
Spurious and Harmonic Rejection
FM Hum and Noise
A
udio Output
A
udio Distortion
A
udio Characteristics
0.25uV 12 dB SINAD
0.22uV 10dB SINAD
65dB (12.5KHz)
70dB
40dB (12.5KHz)
1Vrms
Less than
3%
+1,
-3 dB from 6dB per octave de-emphasis Characteristic from 300 ~ 3000Hz

T
ransmitter Specifications
RF Output
Spurious and Harm
onic
FM Hum and Noise
A
udio Distortion
A
udio Characteristics
Output Impedance
VHF :
10/2 Watt, UHF : 5/2Watt
70dB
40dB (12.5KHz)
Less than
3%
+1,
-3dB from 6dB per octave pre-emphasis Characteristic from 300 ~ 3000Hz
50ohms
3. Specification
3.1 MD-100D/400D Overview
MD-100D/400D are digital RF modem that supports data and voice communication. It supports serial
interface, and it is set and operated with AT command, also it can be applied in various fields.
3.2 MD-100D/400D functions
-. RF Communication Data Speed : 9,600bps
-. Serial Interface support (AT Command) : 115,200 bps
-. Frequency band : 400MHz ~ 470MHz
3.3 MD-100D/400D External Interface
Picture 3-1) Main Pin Specification
Picture 3-2) MD-100D/400D Digital RF Modem

3.4 D-SUB 15Pin Connector Specification
Figure 3-3) D-SUB 15PIN
Pin NO Pin Name Pin Description I/O
1 Not use
2 Not use
3 PTT Low Active I
4 DC12V DC+12V I
5 CTS I
6 Carrier Detector O
7 MIC_IN 30mV @ 2KHz Dev I
8 FLASH_PRO I
9 SPEAKER_OUT 300mV @ 1KHz dEV O
10 RX_DATA 3.3V TTL I
11 TX_DATA 3.3V TTL O
12 RTS O
13 GPS_TX_DATA 3.3V TTL O
14 Ground Ground
15 GPS_RX_DATA 3.3V TTL I

3.5 MD-100D/400D Drawing
Figure 3-4) MD-100D/400D Drawing

4. How to set DIP Switch
4.1. Dip switch setting
Picture 4-1) Dip Switch TX Power setting and channel setting
4.2 TX Power Setting
TX Power is changed by Switch No.6
Factory default TX Power value is High
Dip Switch
Power Value
Low Power
High Power
Picture 4-2) DIP Switch RF Power Setting
4.3 Channel Setting
There are two ways to set the channel: DIP switch and AT command.
DIP switch channel setting method can be set by using DIP switch 1, 2, 3, 4, 5, total 32 channels.
AT Command channel setting has the following rules for the priority of the two methods.
When the power is turned on, the MD-100D / 400D operates as follows.
1) The channel is set according to the DIP switch when booting.
2) When changing channel with AT Command, DIP Switch will be ignored and return to DIP Switch
setting through AT Command (AT * DIP = 1).
DIP Switch Meaning
1 DIP Switch: Binary 5 digit
2 DIP Switch: Binary 4th digit
3 DIP Switch: Binary 3rd digit
4th DIP Switch: 2nd digit in binary
5th DIP Switch: Binary 1st digit
Below is the channel table according to DIP Switch status.
DIP Switch
Binary
Channel Value
00000
1

00001
2
00010
3
00011
4
00100
5
00101
6
00110
7
00111
8
01000
9
01001
10
01010
11
01011
12
01100
13
01101
14
01110
15
01111
16
10000
17
10001
18
10010
19
10011
20
10100
21
10101
22
10110
23
10111
24
11000
25
11001
26
11010
27
11011
28
11100
29
11101
30
11110
31
11111
32
5. MD-100D/400D Operation Mode
MD-100D / 400D supports 3 modes: 1) AT Command mode and 2) continuous mode for keyboard input
or file transfer using Tera term.

MD-100D/400D operation mode
1) AT Command mode
2) 3 Wires continuous mode
-. Operates in 3 Wire Mode (TXD, RXD, GND).
3) 5 Wires continuous mode (used for many data transmission)
-. Supports H / W flow control using TXD, RXD, CTS, RTS, GND.
When the MD-100D / 400D data modem is booted for the first time, AT Command mode is set.
To change from AT Command mode to Continuous mode, use AT Command as shown below.
Description
MD-100D/400D Operation Mode Setting
Query
Answer
AT*CMODE=*
“CMODE : *
“CMODE OK”
Parameters
3WIRES
5WIRES
OFF
Example
AT*CMODE=3WIRES
AT*CMODE=5WIRES
AT*CMODE= OFF
Select the required mode from above
6. AT Command interface
Set the status of MD-100D/400D or user AT Command for function operation. The serial Speed is
115,200 bps.
6.1 VERSION
Description
Command to check the modem version
Query
Answer
AT*VERSION
*VERSION:<value>
Parameters
Example
AT*VERSION
*VERSION:YEONHWA Modem v1.0
OK
6.2 RESET
Description
Command for reset the modem
Query
Answer
AT*RESET
RESET
Parameters
Example
AT*RESET
RESET
Going down terminal…
6.3 MSG
Description
Command for sending a message
Query
Answer
AT*MSG=<value>
OK
Parameters 문자열
Example
AT*MSG=AA
OK
6.4 VOL
Description
Command for the checking or set the modem volume
Query
Answer
AT*VOL?
GET VOLUME(<value>)=(<value>)

AT*VOL=<value>
SET VOLUME(<value>)=(<value>)
Parameters
1 ~ 16
Example
AT*VOL?
GET VOLUME(15)=(150)
AT*VOL=5
SET VOLUME(5)=(47)
6.5 OID
OWN ID setting is available only in CPS program, and can be checked in AT Command only.
Description
Command for checking OWN ID
Query
Answer
AT*OID?
OID:00000001
OK
Parameters
Example
AT*OID?
OID:00000001
OK
6.6 CHKSTAT
Description
Status check command
Query
Answer
AT*CHKSTAT?
*CHKSTAT:STAT OK
OK
Parameters
Example
AT*CHKSTAT?
*CHKSTAT:STAT OK
OK
6.7 DIP
Description
DIP switch is ignored when setting the channel with AT Command. If
you want to change the channel using the DIP switch again, you can
use this command to change the channel so that it can be changed by
DIP Switch operation
Query
Answer
AT*DIP?
*DIP=<value>
OK
AT*DIP=<value>
*DIP SET=<value>
OK
Parameters
1: Channel setting using DIP Switch
0: Channel setting using AT Command
Example
AT*DIP?
*DIP=1
OK
AT*DIP=<value>
*DIP SET=<value>
OK
6.8 CID
Description
Call ID check and setting command
Basically, it communicates with Call I
D set in CPS tool. You can
change the Call ID with this command, and when changing the
channel, it will be reset to the Call ID set in the CPS tool.
Query
Answer
AT*CID?
CUR-CID:<call id>,CF:<call format>

CID[<index>]:<call id>,CF:<call format> [
반복
]
CALLID OK
AT*CID=1
SET CUR-CID:01
CID[01]:00000002,CF:GRP
CALLID OK
Parameters
Example
AT*CID?
CID[00]:00000001,CF:GRP
CID[01]:00000002,CF:GRP
CID[02]:00000003,CF:GRP
CID[03]:00000010,CF:GRP
CID[04]:********,CF:ALL
CALLID OK
6.9 CHSET
Description
Channel setting command (When this command is used, channel value
changed by DIP Switch is ignored.)
Query
Answer
AT*CHSET=<channel number>
CH:<channel number>:<Channel type>,RX:<RX Frequency>,<RX
CC>,TX:<TX Frequency>,<TX CC>
OK
Parameters
Example
AT*CHSET=1
CH:01:DMR,RX:41050000,01,TX:41050000,01
OK
6.10 CHLIST
Description
Show channel list command
Query
Answer
AT*CHLIST?
CUR-CHNUM:<Current channel number>
<number>:<Channel type>,RX:<RX Frequency>,<RX
CC>,TX:<TX Frequency>,<TX CC> [반복]
OK
Parameters
Example
AT*CHLIST?
CUR-CHNUM:04
00:DMR,RX:40550000,01,TX:40550000,01
01:DMR,RX:41050000,01,TX:41050000,01
02:DMR,RX:41550000,01,TX:41550000,01
03:DMR,RX:42050000,01,TX:42050000,01
04:DMR,RX:42550000,01,TX:42550000,01
OK
6.11 MINFO
Description
Current setting parameter display command
Query
Answer
AT*MINFO?
*MINFO:<channel index>,<Radio type>,RX:<RX
Freq>,<CC>,TX:<TX Frequency>,<TX CC>
OID:<Own ID>,CID[<Call ID index>:<Call ID>,CF:<Call format>
OK
Parameters
Example
AT*MINFO?
*MINFO:04,DMR,RX:425500000,01,TX:425500000,01
OID:00000001,CID[00]:00000001,CF:GRP
OK
6.12 PWRLEVEL (Power Level)
Description
Power Level Setting

It is set according to Dip switch 6 at boot, and it can be changed with
this command.
Query
Answer
AT*PWRLEVEL?
GET PWRLEVEL=<value>
OK
AT*PWRLEVEL=<value>
SET PWRLEVEL=<value>
OK
Parameters
0 : Low Power
1 : High Power
Example
AT*PWRLEVEL?
GET PWRLEVEL=0
OK
AT*PWRLEVEL=1
SET PWRLEVEL=1
OK
6.13 VERSION
Description
Command to check the modem version
Query
Answer
AT*VERSION
*VERSION:<value>
Parameters
Example
AT*VERSION
*VERSION:YEONHWA Modem v1.0
OK
1. AT Command Data Configuration
AT*MSG= ASCII Data(80 byte) 0D0A
2. Structure to send text documents using Tera Term wirelessly
1) RS-232C Serial Buffer of MD-100D/400D (Data Modem) has a total of 10 Kbytes.
Each buffer stores 80 bytes of data.
2) Serial transmission Timer transmits maximum 80 bytes after 120msec received buffer check.
-. To improve performance, the Serial Transfer Timer can be reduced by 120msec, and the amount
of data transferred can be increased or decreased.
-. Currently, the amount of data transferred is fixed at 80 bytes.
3) Therefore, if you use a program like Tera Term to input characters on the keyboard, it will be sent
immediately upon input.
4) You can also transfer files using Tera Term.

2) AIR data transfer structure
Since the DMR Data Modem operates in 2: 1 mode, the actual transmission is as follows.
2:1 TDMA : There are two slots (slot1, slot2(30m/s) in a single channel so it operates as the below
picture.
Figure 2: 1 TDMA structure
3. How to use RS232 / RS422 / RS485 / USB / GPIO / Ethernet connection
4. Did you use CTS and RTS for the cable?
1) The serial buffer of MD-100D/400D is 10Kbyte. If you want to transfer a lot of data (when the amount
of data exceeds 10Kbyte), you should use 5-wire serial communication method as below.
Because the RS232 Speed is 115.200bps and the transmission speed of the wireless section is slower
as 9,600bps, memory management must be done in the serial buffer.

When RTS is "LOW" (when the MD-100D/400D modem's serial buffer has space): The PC or external
device sends normal serial data to the modem.
When RTS is "High" (when the serial buffer of the MD-100D/400D modem is full): it stops sending serial
data to the external device.
When CTS is "LOW", data received by modem is transmitted to PC or external device. If it is HIGH, data
is not transmitted to PC or external device.

5. D-SUB 15Pin Change connector specification
1) 5 Pin : GPIO1
→
CTS
2) 12Pin : SERIAL_BUSY
→
RTS
Figure D-SUB 15 PIN
Pin NO Pin Name Pin Description I/O
1 Not use (Not use CTCSS/DCS) I
2 Not use (Not use CTCSS/DCS) O
3 PTT Low Active I
4 Vin(DC12V) DC+12V I
5 GPIO1
→
CTS I/O
→
I
6 Carrier Detector O
7 MIC_IN 30mV @ 2KHz Dev I
8 FLASH_PRO I
9 SPEAKER_OUT 300mV @ 1KHz dEV O
10 RX_DATA 3.3V TTL I
11 TX_DATA 3.3V TTL O
12 SERIAL_BUSY
→
RTS I/O
→
O
13 GPS_TX_DATA 3.3V TTL O
14 Ground Ground
15 GPS_RX_DATA 3.3V TTL I

5. For Safe Operation
5.1Precautions
5.2 Influences on the Operations of Radio or Other Equipment
The radio emits a strong electronic wave, which may have an effect on the operation of oth
er
equipment and also can be influenced by the other devices.
In case of the area that medical equipment are being used, please use the
radio after discussion with the equipment producer or the related doctor.
Please turn off the radio before boarding on the airplane.
When using the radio in the airplane, please follow the rules or the instructions
of the flight attendants.
•
Do not give an excessive shock to the radio.
•
Do not place the radio where the direct sunlight and/or the high temperature
occurs..
•
If the radio is placed for a long time in a car in summer, the hot temperature in
the car maycause explosion of battery.
•
Do not make a damage to the battery by a sharp substance and/or an
excessiveshock.
Do not use other frequency except for the permitted frequency in order not to
be punished by the Radio WavesAct.
Do not disassemble or reorganize the radio. The disassembly or reorganization
will cause a defect or malfunction on the radio. It will be impossible to repair
afterwards. There will also be a punishment made by the Radio WavesAct.
Do not use accessories (such as rechargeable battery, adaptor, external
speaker microphone and earphone etc.) from the other makers, which can
cause defect on battery and malfunction or a defect on the radio.
Do not remove the antenna from the radio or do not transform the antenna or
do not make any changes on the antenna. The strong electronic wave to be
emitted from the radio can have an effect on the performance of the radio and
can cause the radio to have a defect.

6.
Safety Notes
Please make sure to read the followings above for safe and effective use of the radio.
7.
Handling Caution
•
Any changes or modifications not expressly approved by the party responsible for compliance with
the FCC
regulations could void the user's authority to operate the equipment.
•
It is forbidden to install or operate the device other than the responsible person (licensed person).
•The user manual is included in the box.
•How to use and install the product is shown in the figure.
•
An indication of the maximum antenna gain permitted to ensure compliance.
this would be 1.5 dBi.
•
At the area where an electromagnetic force can be made, please make sure
to turn off the power of the radio.
•
The user should limit the operation to 50%.
•
RF SafetyDistance on page 13 to match with RF exposure exhibit: 13.21cm for
Occupational / Controlled, and 29.46cm for General / Uncontrolled.
•
Be careful that if the outer surface of the antenna is peeled off, there is a
danger of a topic.
Please do not use the radio at the place where computer or other
electric/electronic devices are being used. The strong electronic wave from the
radio can have an effect on the equipment.

8.
Usage
Application
▪
Water/Waste Treatment
▪
Plants Oil and Gas Field, SCADA
▪
Security/Alarm System
▪
Gate Systems, Remote Controls
▪
Commercial Sign Control
▪
Automatic Vehicle Location
▪
Murphy/Kill Switches
▪
Weather Monitoring
▪
Irrigation Systems
▪
Emergency Call Boxes
▪
Low Power Repeaters

Warranty Statement
Thank you for purchasing MD-100D/ MD-400D Series.
1. This product has passed strict quality control and testing process by YeonHwa M Tech.
2. Warranty is one year from the day of release.
• When there is malfunction of the product under normal operating conditions during the
warranty period, your authorized dealer and the service center will repair it free of charge.
3. Service fees will be charged for the following cases:
• When performance failed, malfunction or damaged after the warranty period.
• When the product is damaged due to user’s mishandling or improper operation.
• When the product is damaged due to fire, pollution, earthquakes and any other natural or
unnatural conditions, accidents etc.
• Malfunction by not keeping the notices written in the user manual.
• Malfunction by not using the appointed adaptor.
• When the product is damaged due to user’s modification, attempts of repairing rather than
the appointed service center.
4. Product Check List
Model Name
MD-Series
Serial No.
Purchase Date
Purchaser
Name
Address
※Please fill out this check list when purchasing the product.
YeonHwa M Tech Co., Ltd.
36, Jeonparo 44beongil, Manan-gu, Anyang-si, Gyeonggi-do, Korea 14086
TEL: 82-31-444-7270
FAX: 82-31-444-7271
This manual suits for next models
3
Table of contents