HK01x!manual!
1. Connecting the device
!
The!steps!to!connect!the!xxter!device!depend!on!the!model!that!is!used.!
For!all!models!the!UTP!cable!has!to!be!connected!to!the!(internal)!
network.!xxter!has!to!be!able!to!connect!to!the!Internet,!to!download!
the!configuration!and!for!future!firmware!updates.!!
!
KNX$direct$
In!case!you!are!using!an!xxter!model!with!a!direct!KNX-bus!connection!
(HK01!of!HKE01),!then!connect!the!bus!cable!to!pin!2!(KNX!min/black)!
and!pin!3!(KNX!plus/red),!see!image!6.!First!connect!xxter!to!the!KNX-
bus!and!then!connect!xxter’s!power!adaptor!to!the!power!socket.!
!
!
Image$1:$xxter$rear$panel$
$
KNX$connection$over$IP$
When!using!KNX!over!a!KNXnet/IP!module,!please!make!sure!the!xxter!
unit!and!the!KNXnet/IP!module!are!both!connected!to!the!same!
internal!network.!
$
Artnet$DMX$
For!the!use!of!DMX!components,!an!ArtNet->DMX!node!is!required.!
This!node!must!also!be!connected!to!the!same!internal!network!as!the!
xxter!unit.!A!list!of!ArtNet->DMX!nodes!that!are!tested!with!xxter!can!
be!found!on!the!website.!
!
Philips$Hue$
When!using!Philips!Hue,!make!sure!that!the!xxter!unit!and!the!Hue!
network!module!(bridge)!are!both!connected!to!the!same!internal!
network.!