YeriSystems EntraGuard User manual

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 1 of 7 P/N: 01552-001 Rev. B
This installation guide provides basic installation information, drawings, and controller setup instructions to use when
installing the EntraGuard Silver Telephone Entry controller. The EntraGuard Silver controller may be used alone or may
be connected to an access control network using PXL-500 or PXL-250 family controllers. For instructions on how to
install a postal lock, see the EntraGuard Postal Lock Installation Application Note (P/N 01964-001).
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the
installation.
Section 1 - Drawings
Section 2 - RS-232 Serial Port
Section 3 - Setup Controller
Section 4 - Contact Keri Systems
1.0 Drawings
1.1 EntraGuard Silver Enclosure
Figure 1: The EntraGuard Silver Telephone Entry Enclosure

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 2 of 7 P/N: 01552-001 Rev. B
1.2 Silver Telephone Entry Controller
Figure 2: The Silver Telephone Entry Controller
NOTE: You must power down the unit before attempting to make or remove any connections. Failure to do so will
damage the controller.
NOTE: In order to use the internal modem in the Silver Controller, Jumper 11 must be set.

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 3 of 7 P/N: 01552-001 Rev. B
1.3 Board Placement of a PXL Controller
Figure 3: Silver Board with Optional PXL-5xx Board Placement
NOTE: For information on the optional PXL-500/PXL-510 board, see the PXL-500/PXL-510 Quick Start Guide
(P/N 01918-001). For information on the optional PXL-500G-1 board and gate control, see the PXL-500G-1 Quick Start
Guide (P/N 01532-001).

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 4 of 7 P/N: 01552-001 Rev. B
2.0 RS-232 Serial Port
Using the RS-232 serial port for communication between the EntraGuard unit and the host computer may be done one of
two ways:
• by direct connect (maximum of 50 feet)
• through an external modem.
2.1 Direct Serial Connection
The Keri Systems part number for this cable is KDP-552.
Figure 4: PC/DB-9F to Telephone Entry/TB-12 RS-232 Direct Serial Connections
2.2 Modem Connection
The Keri Systems part number for this cable is KDP-929M.
Figure 5: Modem/DB-9M to Telephone Entry/TB-12 Serial Port Connection

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 5 of 7 P/N: 01552-001 Rev. B
3.0 Setup Controller
If you're turning system power on for the first time, certain tasks must be performed prior to entering access control
information from Doors. On the EntraGuard Silver main board (see Figure 2 on page 2), hold the Reset Button (SW1)
down and turn the controller’s power on. After the controller beeps once, indicating the controller’s firmware is ready for
programming, release the SW1 button. The LCD on the front panel will display the Reset Menu (see Figure 6). From this
menu you may perform these tasks: set the controller’s address, clear the controller’s memory, set the microphone
volume, and check diagnostics.
Figure 6: Reset Menu
NOTE: If no keys have been selected within 60 seconds, the unit will time out and go directly to the default message. In
order to reach the Reset Menu, the unit must be powered up again.
3.1 Set Unit Address
The controller’s address may only be set through the Reset Menu. Once you have performed the necessary steps to reach
the Reset Menu as described above. To set the desired operating address for the controller, press 1 on the keypad. The Set
Panel Address screen appears on the LCD (see Figure 7).
Figure 7: Set Unit Address
The address range is from 1 to 128. The Master Controller must be set to address 1. Other slave EntraGuard/PXL
controllers may be assigned any number from 2 to 128. If the network is made up of PXL-250s, the EntraGuard Silver
must be set as the Master.
If the address shown as Current is correct, you may either enter the same address and press *, or just press * to return to
the reset menu. If you do not enter a new address, or enter the same address that is already assigned to this unit, you will
need to clear the memory separately (see “Clear the Controller’s RAM” on page 6).
NOTE: Changing the address of an EntraGuard Silver controller completely erases all information within the controller.
It is vitally important that you collect all event data from the controller before changing the address. Once the address is
changed (and the RAM is automatically cleared) the event information in the controller is lost and cannot be recovered.
If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The
number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been
entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown as
Current, the controller will automatically clear the memory as it changes the address (see Figure 8).

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 6 of 7 P/N: 01552-001 Rev. B
Figure 8: Clearing Memory
Once the memory has been cleared, the unit is ready to be configured. The LCD will display a message that the unit has
not been initialized. This display will rotate with the EntraGuard Default display until a Total Update from Doors has been
performed on the unit. Once an update has been performed, only the default will be displayed.
3.2 Clear the Controller’s RAM
When turning system power on for the first time, the controller’s memory needs to be cleared of any spurious information
that may be in the RAM. If you changed the controller address, the memory is automatically cleared. However, if you did
not change the address, you will need to clear the controller’s RAM separately. From the Reset Menu (see Figure 6 on
page 5), press 2 to Clear Memory. The Clear Memory screen will appear on the LCD (see Figure 9).
Figure 9: Clear Memory
From the Clear Memory Screen you may either:
1. Press 1 to clear the controller’s RAM. The LCD will change to show the memory is being cleared (see Figure 8).
Once the controller’s RAM has been cleared, the unit is ready for use. The LCD will rotate between the Initialization
Warning and EntraGuard Default screens until a Total Update from Doors has been performed on the unit.
or
2. Press 2 to return to the Reset Menu without clearing the controller’s RAM.
NOTE: Clearing the system RAM completely erases all information within the EntraGuard Silver controller, except for the
controller address. If there is any information in system RAM from an access control installation and the system RAM is
cleared, the information in the controller is lost and cannot be recovered, and a Total Update must be performed.
3.3 Diagnostics and Troubleshooting
For information regarding the diagnostics screens and troubleshooting the EntraGuard Silver Controller, see the
EntraGuard Troubleshooting and Diagnostics Guide (P/N 01912-001).

EntraGuard®Silver Telephone Entry Control
Installation Guide
Page 7 of 7 P/N: 01552-001 Rev. B
4.0 Contact Keri Systems
- end of document -
Keri USA Keri UK, Ireland, Europe
2305 Bering Drive
San Jose, CA 95131 Unit 17
Park Farm Industrial Estate
Ermine Street
Buntingford
Herts SG9 9AZ UK
Telephone: (800) 260-5265
(408) 435-8400 Telephone: + 44 (0) 1763 273 243
Fax: (408) 577-1792 Fax:+ 44 (0) 1763 274 106
Web: www.kerisys.com Web:www.kerisystems.co.uk
E-mail: [email protected]
Table of contents
Popular Intercom System manuals by other brands

GE Security
GE Security CC-SCRS01 installation instructions

HIK VISION
HIK VISION DS-KH6320-TE1B Operation guide

Bitron Video
Bitron Video AV1860/1 instruction manual

Timeguard
Timeguard DCC3 operating instructions

Clear-Com
Clear-Com RM-220 Instruction and service manual

HIK VISION
HIK VISION DS-KIS701-W-D user manual