manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. YOODA
  6. •
  7. Receiver
  8. •
  9. YOODA GAMMA X 1Cw User manual

YOODA GAMMA X 1Cw User manual

Popular Receiver manuals by other brands

Televes ZAS HD SAT user manual

Televes

Televes ZAS HD SAT user manual

Realistic DX-75 Operating and service instructions

Realistic

Realistic DX-75 Operating and service instructions

Saris 4620 Assembly instructions

Saris

Saris 4620 Assembly instructions

Mini DTR 206C PVR user manual

Mini

Mini DTR 206C PVR user manual

RF Elements TwistPort manual

RF Elements

RF Elements TwistPort manual

Denon DN-200WS user guide

Denon

Denon DN-200WS user guide

Yamaha RX-V467 owner's manual

Yamaha

Yamaha RX-V467 owner's manual

Russound SaphIR 858 instruction manual

Russound

Russound SaphIR 858 instruction manual

Quasonix RDMS Firmware update procedure

Quasonix

Quasonix RDMS Firmware update procedure

Pioneer XV-HTD1 Service manual

Pioneer

Pioneer XV-HTD1 Service manual

ATZ HDMI-V2-44HE150 manual

ATZ

ATZ HDMI-V2-44HE150 manual

Sony XNV-770BT MyTomTom Specifications

Sony

Sony XNV-770BT MyTomTom Specifications

Grundig STR 7122 TWIN Service manual

Grundig

Grundig STR 7122 TWIN Service manual

Creative Blaster Modem user guide

Creative

Creative Blaster Modem user guide

Panduit ATLONA AT-OME-RX11 installation guide

Panduit

Panduit ATLONA AT-OME-RX11 installation guide

VOLTCRAFT UTPS-40 operating instructions

VOLTCRAFT

VOLTCRAFT UTPS-40 operating instructions

JVC KW-ADV794 instructions

JVC

JVC KW-ADV794 instructions

Litelink VT-1001 operating instructions

Litelink

Litelink VT-1001 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

In order to fully explore available functions of GAMMA series please take a moment andread this manual before using the device.
GAMMA reciver are compatible with all YOODA brand devices.
Single-channel GAMMA X wall-mounted control unit (GAMMA_X_1Cw)
1. Control:
can control single motor
2. Memory:
up to 20 transmitters
3. Range:
200 meters outdoor,
35 meters indoor
4. Power supply:
230 V / 50 Hz
5. Output voltage:
230 V / 50 Hz
6. Output power:
500 W
7. Dimensions:
130 x 80 x 44 mm
8. Operating temperature:
from -20°C to 50°C
9. Protection degree:
IP 30
10. Work mode choice
(pulse or standard mode)
11. Switch connect.
(pulse or standard)
12. Lighting connect (max 250 W)
Radio receiver range is a variable value and can differ from declared values depending on conditions in which device
operates. Possible sources of changes in range are building construction, interference caused by other radio transmitters
etc.
GAMMA_X_1Cw
www.sukcesgroup.pl
1. General information
2. Detailed description
1
LED diode (power)
LED diode (programming)
Programming button (S4)
Digital display
Programming button (S5)
Jumpers (set reaction of the unit to
the photocell signal and work mode)
Fuse 10A/250V
Screw clamps
J3 J1 J2
PA2
R25 R25
R36
S4
Remember to set the correct direction of the motor work, because the photocell operates only in the down direction.
The neutral motor cable must be connected to the unit otherwise it will not work properly.
3. Connection
4. Photocell connecting
2
Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence
(SEP - Association of Polish Electrical Engineers) or equal license. Device is designed to operate in places shielded from
unfavourable weather conditions. Motor should be installed in accordance with all provisions of regional law and professional
standards. All cables connecting power receiver with electric source should be protected from overload and short-circuits
effects with devices automatically disconnecting power. Device should be powered with a separate source and protected
only with a fast-blow fuse (never slow-blow fuse). Creating electrical system using inadequate fuse may result in loosing
rights under the provisions of warranty. When connecting device to power source with cables with adequate cross-section
should be used. Long-lasting output load capacity table should be the ground for choosing adequate cables.
It is not allowed to connect photocell's signal or power wires.
Configuration of the unit with photocells connected.
motor:
230V / 50Hz
power:
230V / 50Hz
lightning
(max.250W)
L L LR N N N S
GND VCC UP DOWN
photocell photocell
R36
S4
Open
Stop
NO
NC
3
Press programming
button S4.
Press programming
button S5 to choose number 3.
Press
programming button S5
to choose number from 0 to 9.
To confirm hold
the programming button S5
for about 2 seconds.
Automatic time door
closing has been set.
Press and hold
S5 programming button
for about 2 seconds.
5. Programming
of automatic door closing
Automatic closing is disabled when you set the unit to "0".
Numbers from 1 to 9 correspond to the time in minutes.
Connecting the photocells "A" to the GAMMA X receiver
Connecting the photocells "B" to the GAMMA X receiver
Vcc 12 V DC [+]
S [signal]
GND [masa]
0 V. / DC [-]
12 V. DC [+]
24 V. DC [+]
C
NC
NO
0 V. / DC [-]
12 V. /DC [+]
24 V. / DC [+]
L L LR N N N S
GND VCC UP DOWN
max 5 m
RECEIVER TRANSMITTER
Vcc 12 V DC [+]
S [signal]
GND [masa]
0 V. / DC [-]
12 V. DC [+]
NO
C
NC
0 V. / DC [-]
12 V. /DC [+]
L L LR N N N S
GND VCC UP DOWN
max 5 m
RECEIVER TRANSMITTER
PA2
R25
4
The selected
option has been set.
Press
programming button S4.
Press programming button S5
to choose number 8.
Press and hold
S5 programming button
for about 2 seconds.
Press programming button S5
to choose number 0 or 1.
To confirm hold
the programming button S5
for about 2 seconds.
Work mode unit
has been set.
Press
programming button S4.
Press programming button S5
to choose number 6.
Press and hold
S5 programming button
for about 2 seconds.
Press programming button S5
to choose number 0 or 1.
To confirm hold
the programming button S5
for about 2 seconds.
Press
programming button S4.
Press programming button S5
to choose number 5.
Press and hold S5
programming button
for about 2 seconds.
Press programming button S5
to choose number 0 or 1.
To confirm hold
the programming button S5
for about 2 seconds.
6. Programming of latching mode
7. Programming work mode of the unit
8. Changing work motor direction
- Latching mode is OFF - Latching mode is ON
- Closing from each option - Closing only from the upper limit position
Press
programming button S4.
Press
programming button S5
to choose number 7.
Press
programming button S5
to choose number 0 or 1.
or
or
or
or
To confirm hold
the programming button S5
for about 2 seconds.
The selected
automatic door closing
option has been set.
Press and hold
S5 programming button
for about 2 seconds.
Setting this option causes holding the power supply after reaching the end position. After a power failure, the setting is
reset to the default value (0-backup option disabled).
Remember to set the correct direction of the motor work, because the photocell operates only in the down direction.
Direction of the motor
work has been changed.
Continuous work
(Pressing the button on the remote control causes
the motor run continuously to the limit position).
Interrupted work
(Pressing the button on the remote control
causes a short movement of the motor).
5
Press and hold
programming button S5
for about 2 seconds.
Press UP button in standard mode
or press any different button
in pulse mode.
Press and hold
programming button S5
for about 2 seconds.
Press DOWN button.
10. Adding transmitter
11. Deleting transmitter
12. Deleting all transmitters
13. Choosing swich mode
Transmitter work mode
has been set.
Transmitter
has been programmed.
Transmitter
has been removed.
All transmitters
has been removed.
Press
programming button S4.
Press programming button S5
to choose number 1.
Press and hold
S5 programming button
for about 2 seconds.
Press programming button S5
to choose number 0 or 1.
To confirm hold
the programming button S5
for about 2 seconds.
Press
programming button S4.
Press
programming button S5
to choose number 4.
Press and hold
S5 programming button
for about 2 seconds.
9. Programming work mode of the transmitter
It is possible to set independent work mode for each programmed transmitter.
The procedure must be performed every time before adding a new transmitter otherwise transmitter will accept previous
setting.
- Pulse mode (step by step) - Standard mode (UP, STOP, DOWN)
Swich mode
has been set
Press
programming button S4.
Press
programming button S5
to choose number 2.
Press and hold
S5 programming button
for about 2 seconds.
Press
programming button S5
to choose number from 0 to 3.
To confirm hold
the programming button S5
for about 2 seconds.
- Latching switch - Non-latching switch - Impulse switch