Compatibility Options / Accessories / Models
STANDARD LOW BODY
LASER CONCEALED
Code designation YLV YLH YLV-AF YLH-AF YLIV YLIH YLIV-AF YLIH-AF YLVR YLIVR
Coils and heaters**
BA1** Additionnal 1 row heating llllllllll
KREL** Kit electrical heater with safety thermostat and relay llllllll
Factory fitted thermostat
CSL00 Fan speed selector (buit in) llllllllll
CML00 Thermostat with manual fan speed and S/W change
over (buit in) l l
CEL00 Thermostat with manual fan speed, dead band,
automatic change over (buit in) Compatible with electrical heaters l l
CEL20 Thermostat with automatic fan speed, dead band,
automatic change over (buit in) Compatible with electrical heaters l l
CEL30 Thermostat with automatic fan speed, dead band,
automatic change over for modulating valves (buit in) l l
Remote controllers and thermostats
CSR00 Fan speed selector (wall mounted) llllllllll
CMR00 Thermostat with manual fan speed and S/W change
over (wall mounted) l l
CER00 Thermostat with manual fan speed, dead band,
automatic change over (buit in) Compatible with electrical heaters l l
CER20 Thermostat with automatic fan speed, dead band,
automatic change over (buit in) Compatible with electrical heaters l l
CER30 Thermostat with automatic fan speed, dead band,
automatic change over for modulating valves (buit in) l l
CBL20 Parallel connection for ON/OFF valve llllllllll
CBL30 Parallel connection for modulating valve llllllllll
Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)
J3A2 (2p) 3-way 4-ports on/off valves for 2-pipe systems llllllllll
J3A2 (4p) 3-way 4-ports on/off valves for 4-pipe systems llllllllll
J3AM (2p) 3-way 4-ports modulating valves for 2-pipe systems llllllllll
J3AM (4p) 3-way 4-ports modulating valves for 4-pipe systems llllllllll
DT (2p) Shut-off valves for 2-pipe systems
(in addition to J3A2/J3AM valves) llllllllll
DT (4p) Shut-off valves for 4-pipe systems
(in addition to J3A2/J3AM valves) llllllllll
PC Condensate pump llllllllll
WS Water sensor Compatible with CEL/CER
TM Minimum temperature thermostat llllllllll
Feets and panels
CP1 Set of painted feet l l
ZL1 Set of feet + frontal socle l l
PPV1 Vertical painted back panel l l l
PPH1 Horizontal painted back panel l l
External air intake
PA Air intake plenum l
PAS Air intake plenum collars l
PA90° 90° air intake plenum l
RCA Air intake duct fitting l
PM Air delivery plenum with collars llll l
PM90 90° air delivery plenum llll l
lCompatible
Compatible with conditions
Not compatible
** Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.
Compatibility tables for FCU
LASER and LOW BODY