1.1 product introduction
1.2 product introduction
2.5 Key definition
2.7 User settings
2.8 fault information
2.9 Wiring definition
2.6 Function operation
1.3 Scope of use
1.4 Appearance and size
1.5 Display coding rules
2.Product description
3.Attention
2.1 Specification parameters
2.2 Function overview
2.3 Installation method
2.4 Display interface
2.4.1 Turn on interface
2.4.2 Riding interface
2.6.1 On/Off
2.6.2 Power shift switching
2.6.3 Assist in implementation
2.6.4 Headlights on (brightness switching)
2.6.5 Electricity display
2.7.1 Enter Settings
2.7.2 unit setting
2.7.3 Wheel diameter information
2.7.4 Speed limit information
2.7.5 Battery voltage
2.8.1 Fault display
2.8.2 Definition of Fault Code
2

1. product introduction
1.1 product name and model
1.2 product introduction
1.3 Scope of use
1.4 Appearance and size
LCD Display, model: DZ40
1.4.1 Display shape and size
3
EN15194 electric bicycle
The housing material of the product is ABS, and the upper housing window is made
of brown PC with high hardness.
Simple and thin, installed on the left, can be used with the middle display;
High brightness white nixie tube;
Waterproof lever: IP65;
UART communication interface is convenient for maintenance service

4
2. Product description
1.5 Display coding rules
2.1 Specification parameters
2.2 Function overview
SW102 product model (this information is not included in bar-code information);
C-manufacturer code or production team code;
S2-product model code;
C01-indicates the number of weeks in the production year;
B-indicates the hardware version;
101-indicates the firmware version number;
0001-indicates the serial number of the product.
①power supply: DC 24V/36V/48V
②rated current: 18mA/36V
③shutdown leakage current: < 1uA;
④Display is similar: white digital tube display
⑤Communication mode: UART (default)
⑥Working temperature:-20°C ~ 60°C
⑦Storage temperature:-30°C ~ 80°C
⑧Waterproof level: IP65
① Four buttons, easy to operate
② Speed display: real-time speed
③ Gear control: default gear 0-5
④ Six-level battery indication: 1-5 battery levels and under-voltage prompt
⑤ Walk-assist function
⑥ Headlight indication: headlight status indication (supported by controller)
⑦ Fault code indication

5
2.3 Installation method
2.4 Display interface
2.4.1 Turn on interface
Start up and display the character pen segment as a ticker, and then the pen segment
will flash twice.
2.4.2 Riding interface
①gear indication: 0-5 gears, gear indication.
②Speed display: real-time speed display.
③ Power indicator: Level 6 power indicator: Level 1-5
power and under-voltage prompt (1 light flashes).
①Open the display locking clip, cover it on the left handlebar
(standard handle pipe size: φ 22.2), adjust it to an easy-to-operate position, fix it with
M3 inner hexagon and tighten the fixing screw. The locking torque is 0.8N.m. * display
damage caused by excessive torque is not covered by warranty.
②Connect the display connecting 5pin plug-in with the controller docking connector
as indicated.
Front light icon
Gear
Battery indicator
Error warning icon
Speed

6
Press and hold the key for 1 second, then the headlights will turn on (with the
support of the controller), the lamp icon will light up, and the brightness of the display
lamp will decrease. Press and hold the key again for 1 second, then the headlights
will turn off and the display brightness will recover.
2.5 Key definition
gear 0 gear 1 gear 2 gear 3 gear 4 gear 5
2.6 Function operation
Switch on/off: function key: adjustment key+:upper part of display display area
(explained by ), adjustment key-:lower part of display display area (explained by )
Press the key or the key to switch the assist gear and change the assist
mode. There are four modes: 0/ low/medium/high gear.
Press and hold the button for 2 seconds, and then enter the boosting state.
Release the button and exit the boosting
2.6.1 On/Off
2.6.2 Power shift switching
2.6.3 Assist in implementation
2.6.4 Headlights on (brightness switching)
Implementation mode.
M
>
>
>
>
>
>>
>
Keep the normal connection state between the display and the controller, press the
key for 2 seconds when the display is turned off, and the display will fully display the
startup interface, then enter the basic interface normally and start working; Long press
the (2 seconds) in the power-on state to turn off the display. If the rider does not
operate the display for 5 minutes (default) (and the speed is 0), the display will
automatically turn off.

7
2.6.5 Electricity display
Turn off the lights (high brightness)
and turn on the lights (low brightness)
Battery charge (C) display correspondence table (charge indication can be adjusted
according to requirements)
When the battery power is normal, the battery 5-segment LCD displays the power
according to time and the outer frame lights up. When the battery is exhausted, the
5-segment LCD of the battery is completely extinguished and the outer frame flashes, so
it needs to be charged immediately. The battery charge is shown as follows:
serial
number
1C≤5% U≤23.1
23.1<U<24.5
24.5≤U<25.1
25.1≤U<25.6
25.6≤U<27
U≥27
U≤33
33<U<34.7
34.7≤U<35.8
35.8≤U<36.7
36.7≤U<38.5
U≥38.5
U≤42.9
42.9<U<45.1
45.1≤U<46.5
46.5≤U<47.5
47.5≤U<50.1
U≥50.1
Battery outer
frame flashes
One grid
Two-grid
Three-grid
Four-grid
Five-grid
5%<C<15%
15%≤C<35%
35%≤C<55%
55%≤C<75%
C≥75%
3
4
5
6
2
On-display
(SOC)
Showed on
the display Voltage (24V) Voltage (36V) Voltage (48V)
2.7 User settings
Setting items: unit setting, * wheel diameter information, * speed limit information,
* battery voltage,(* is a fixed display item, and no user setting option is provided)

8
M
M
>
>
>
>
Within 10 seconds of starting up, press and hold the (2 seconds), and the system
will enter the user setting interface. In this state, relevant parameters can be set and
viewed.
Long press the (2 seconds) to exit and save the setting status.
When the user sets the interface state, if it is not operated for 10 seconds, the display
will return to the normal riding state without saving the parameter settings.
In the user setting interface state, within the setting items, press / briefly to
switch the setting contents.
After entering the setting interface, press / briefly to switch the setting content
to enter the wheel diameter information (the second section of the gear flashes and the
fifth end is always on). Wheel diameter information can be viewed (700C is used instead
of 7c, 27.5 is used instead of 27).
2.7.1 Enter Settings
2.7.2 unit setting
2.7.3 Wheel diameter information
Metric system (KM) English system (MI)
Enter the setting interface (default unit setting item: the first segment of gear flashes,and
the fifth end is always on).
You can view the unit mode metric KM/ imperial m switch, and the factory default value
is KM.(with 7-segment LED standard alphabet)

9
After entering the setting interface, press the / briefly to switch the setting content
to enter the battery voltage check (the fourth segment of the gear flashes and the fifth
end is always on).The collected battery voltage information can be viewed (two digits
indicate, decimal places are rounded off).
After entering the setting interface, press / briefly to switch the setting content to
enter the wheel diameter information (the third section of the gear flashes and the fifth
end is always on). You can view the speed limit information (the default speed limit is
25km/h).
2.7.5 Battery voltage
The speed limit is 25 km/h
26inch 700C
>
>
>
>
2.7.4 Speed limit information

10
The voltage is 36V
2.8 fault information
2.8.1 Fault display
The fault icon and fault code are displayed, and the fault code flashes.
2.8.2 Definition of Fault Code
The fault code is obtained from the controller instruction.
Generally, the controller defines the meaning of error
codes. The meter only defines ERROR 30 that cannot
communicate.
Fault code
E30
Fault description
Communication failure, the display can't
receive data from the controller or the
received data is wrong data.
1: Check whether TX and RX
communication lines are connected
correctly.
2: Check whether the harness and
connector are loose or broken.
3. Check whether the display
communication protocol matches
Investigation and analysis

11
3. Attention
Display outlet terminal Connector connect to the controller
During use, pay attention to the safety of use, and do not plug and unplug the display
under the condition of power supply;
Try to avoid using in harsh environment, such as heavy rain, heavy snow and
exposure.
When the display cannot be used normally, it should be repaired as soon as possible.
Standard line
sequence
1 Red (VCC) display power cord
Power control line of controller
display ground wire
Data receiving line of display
Data transmission line of display
Blue (Kp)
Black (GND)
Green (RX)
Yellow (TX)
3
4
5
2
Standard line color function
2.9 Wiring definition
Table 1 Standard connector wiring definition table
Note: Some products with waterproof plug-in, the user can not see the lead color
in the harness.

Table of contents