When the controller powers on, the unit will run self-qualify mode and automatically show below
items on LCD before going into charging process
Self-test starts, digital meter segments test
Software version test
System battery voltage and current test
External battery temperature sensor test (if connected)
Absorption voltage test
Float voltage test
Self-test completed
CONTROLER OPERATION – LCD DISPLAY
SYSTEM BATTERY VOLTAGE SETTING
Press and hold the SET UP button for 3 seconds to go into the system battery voltage setting
mode, press PV / + or BATT / - button to select your desired system battery voltage 12V, 24V or
AUTO, press the SET UP button again to confirm the battery voltage setting.
THE DISPLAY IN SEQUENCE:
SYSTEM BATTERY TYPE SETTING
Please check your battery manufacturer’s specifications to select correct battery type. The unit
provides 9+1 custom battery types for selections: LI-95, LCO, LTO, LFP, Crystal (Lead crystal), Gel,
AGM, WET (Conventional lead acid) and Calcium (Calcium contented) battery plus Custom setting.
To set the battery type, press the SET UP button to go into your battery type setting mode, the
battery type you select will be flashed on the LCD meter, the default setting is AGM Battery; the
controller will automatically memorize your battery type setting.
CUSTOM SETTING
This solar controller provides a CUSTOM mode to meet your special battery charging demand, the
users can preset the Absorption voltage level and duration, Equalization voltage level, duration
and periodical cycle, Float voltage level and Reset voltage level for your targeted battery charging
parameters.
Alternatively display Absorption Volage character AbS.U and voltage data when going into
CUSTOM mode
The controller will automatically memorize your previous battery voltage setting, If AUTO mode
selected, the controller will automatically detect 12V or 24V battery connected.
LFP battery shown in LCD indicates Lithium Iron Phosphate battery, LiFePO4 battery. LI-95 shown
in LCD indicates the battery profile keeps your LiFePO4 battery charged at 95% LTO battery shown
in LCD indicates Lithium titanate oxidized, Li4Ti5O12 battery.
Press PV / + or BATT / - button to navigate your desired battery type as below:
Press the SET UP button again, the selected battery type will be solid On and confirmed.
Absorption voltage setting range from 13.20V ~ 15.50V, press PV / + or BATT / - button for once +/-
0.05V variation, press the SET UP button again to confirm the absorption voltage level you preset,
then move to next Absorption duration setting.
Alternatively display Absorption Time character AbS.T and duration data; Absorption duration
setting lasted from 5 – 500 minutes, press PV / + or BATT / - button for once +/- 5 minutes variation,
press the SET UP button again to confirm the absorption duration setting, then move to next
Equalization voltage setting.
Alternatively display Equalization voltage character EqL.U and voltage data; Equalization voltage
setting range from 13.20V ~ 16.2V, press PV / + or BATT / - button for once +/- 0.05V variation, press
the SET UP button again to confirm the Equalization voltage and then move to next Equalization
duration setting.
Alternatively display Equalization Time character EqL.T and duration data; Equalization duration
setting lasted from 5 – 500 minutes, press PV / + or BATT / - button for once +/- 5 minutes variation,
press the SET UP button again to confirm the Equalization duration setting and then move to next
Equalization periodical cycle setting.
Alternatively display Equalization periodical cycle character EqL.P and cycle day; Equalization
periodical cycle day setting P.7/11 from 0 – 100 days, press PV / + or BATT / - button for once +/- 1
day variation, 0 indicates no Equalization setting; press the SET UP button again to confirm the
Equalization periodical cycle setting and move to next Float voltage setting.
Alternatively display Float voltage character FLT.U and voltage data; Float voltage setting range
from 13.00V ~ 14.00V, press PV / + or BATT / - button for once +/- 0.05V variation, press the SET UP
button again to confirm the Float voltage and then move to next Reset/Rstart setting.
Press PV / + button in sequence, the LCD will display in turn with solar input voltage, current,
power and kWh.
Press BATT / - button in sequence, the LCD will display in turn with battery voltage, charging
current, charged capacity (Amp-hour) and battery temperature (if external temperature sensor
connected)
The users also can read the battery temperature as degree centigrade or Fahrenheit degree by
pressing SET UP button for converting.
Alternatively display voltage and FUL when battery is fully charged
Alternatively display Reset/ Restart voltage character rST.U and voltage data; Reset voltage setting
range from 12.50V ~ 13.50V, press PV / + or BATT / - button for once +/- 0.05V variation, press the
SET UP button again to confirm the Reset / Restart voltage and all settings will be automatically stored.
You also can visually monitor your battery charging condition for each battery; there is an LCD bar
to show the percentage of charge, you can easily see the battery is charged to 25%, 50%, 75% or
100%, and also roughly match each charging stage of Soft-start, Bulk, Absorption and Float.
The LCD also can be treated as an independent voltage meter or thermometer at night.
LCO BATTERY TYPE SETTING IS ONLY RECOMMENDED WORKING WITH 3-SERIES LITHIUM
COBALT OXIDE LICOO2 BATTERY
CAUTION: INCORRECT BATTERY TYPE SETTING MAY DAMAGE YOUR BATTERY.
SOLAR INPUT PARAMETER DISPLAY
Once the settings are completed, the solar controller will automatically go into charging process,
the LCD displays the parameters of solar input as below:
TECH SUPPORT 541-728-0924 support@zampsolar.com