Important
Upon completion of installation, always check:
lthat all the joints are completely sealed by using a
soapy solution, never a flame;
lthat the gas pressure has been regulated to 1.00kPa
for Natural Gas and 2.75kPa for Universal-LPG. The
pressure test point is located on the regulator for
Natural Gas models or at the top left hand rear of the
cooker for U-LPG models. The pressure should be
measured and adjusted ith the Wok burner on high
flame;
lthat the automatic ignition system is operating
satisfactory on all burners, both individually and in
combination;
lthat the burners operate correctly, are stable, ithout
yello tipping or excessive noise on high and lo
flame.
Then demonstrate to the customer the appliance
operation and leave these instructions.
FO 2365
A) Ramp with ending nut
B) Seal
C) Adjustableconnection
Fig. 3
Important
This cooker must be installed by qualified personnel.
The manufacturer ill not accept liability, should the above
instructions or any of the other safety instructions
incorporated in this book be ignored.
Regulations
This appliance shall be installed in accordance ith the
manufacturers installation instructions, local gas fitting
regulations, municipal building codes, AS5601 (AG601)
and any other relevant statutory regulations.
Data label
The data label is located centrally on the back frame of
the appliance. This appliance is suitable for Natural or
Universal LPG. Ensure that the gas supply matches the
data label. A duplicate of the data label is supplied in the
packaging of the user manual and must be attached to
readily accessible adjacent surfaces of the appliance.
Ventilation
Ventilation must be in accordance ith AS5601 (AG601)
Installation Code. In general, the appliance should have
adequate ventilation for complete combustion of gas,
proper flueing and to maintain temperature of immediate
surroundings ithin safe limits.
Connection to the gas supply
Gas connection must be carried out in conformity ith
the regulations in force. The appliance leaves the factory
tested and regulated for the type of gas indicated on the
plate hich is situated in the lo er position near the gas
connection tube. Ascertain that the type of gas ith hich
the appliance ill be supplied is the same as that indicated
on the plate.
If different carry out all the operations according to the
indications cited in the paragraph adaption to different
types of gas.
For a maximum output and minimum consumption
ascertain that the pressure of the gas used has the values
indicated in the table of burner characteristics.
The joint is mounted on the intake area of the pipe, fitted
ith a filleted nut G 1/2, bet een the sealing components.
Scre the parts ithout forcing, turn the joint in the
direction required and then tighten everything.
Connection
Carry out the connection to the gas plant only by means
of a rigid metallic pipe conforming to the regulations
in force.
The joint for the entry of gas into the appliance is threaded
R 1/2 tapered.
Carry out the connection avoiding any type of stress on
the appliance.
Location
Choose a location free of draughts and open doors and
clear of combustible materials or other fire hazards such
as curtains, etc. The location should ensure convenience
of operation and service. Any adjacent all surface
situated ithin 200mm from the edge of any hob burner
and above the height of the hob must be a suitable non-
combustible material for a height of 150 mm for the entire
depth and idth of the cooker.
Any combustible material above the hotplate must be at
least 650 mm above the top of the hob and no
construction shall be ithin 450 mm above the top of the
burner.
A minimum distance of 100 mm. must be left bet een
the side edges of the hob and any adjacent cabinets or
alls.
Important safety requirements
Natual gas appliances must be fitted ith a pressure
regulator and be installed at the inlet connection. The
gas pressure must then be set as a part of the
commissioning procedures.
For U-LPG the pressure adjustment is made via the
regulator fitted at the domestic cylinder.