manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zanussi
  6. •
  7. Refrigerator
  8. •
  9. Zanussi 102028 User manual

Zanussi 102028 User manual

This manual suits for next models

9

Other Zanussi Refrigerator manuals

Zanussi ZFC 18/9 SRD User manual

Zanussi

Zanussi ZFC 18/9 SRD User manual

Zanussi ZI 720 K User manual

Zanussi

Zanussi ZI 720 K User manual

Zanussi ZRA226CWO User manual

Zanussi

Zanussi ZRA226CWO User manual

Zanussi ZFC 85 L User manual

Zanussi

Zanussi ZFC 85 L User manual

Zanussi ZDC 75-4 User manual

Zanussi

Zanussi ZDC 75-4 User manual

Zanussi ZI 2403 User manual

Zanussi

Zanussi ZI 2403 User manual

Zanussi ZQS 614 0A User manual

Zanussi

Zanussi ZQS 614 0A User manual

Zanussi ZCO 99/4 W User manual

Zanussi

Zanussi ZCO 99/4 W User manual

Zanussi ZBB6284 User manual

Zanussi

Zanussi ZBB6284 User manual

Zanussi ZFT 25 User manual

Zanussi

Zanussi ZFT 25 User manual

Zanussi ZRB 625 MW User manual

Zanussi

Zanussi ZRB 625 MW User manual

Zanussi 726321 User manual

Zanussi

Zanussi 726321 User manual

Zanussi ZBB 6286 User manual

Zanussi

Zanussi ZBB 6286 User manual

Zanussi ZRG15801WA User manual

Zanussi

Zanussi ZRG15801WA User manual

Zanussi ZRB34ND User manual

Zanussi

Zanussi ZRB34ND User manual

Zanussi ZC 242 R User manual

Zanussi

Zanussi ZC 242 R User manual

Zanussi ZK 61/28 RN User manual

Zanussi

Zanussi ZK 61/28 RN User manual

Zanussi ZFC 55 LE User manual

Zanussi

Zanussi ZFC 55 LE User manual

Zanussi ZF72/55M Operating and safety instructions

Zanussi

Zanussi ZF72/55M Operating and safety instructions

Zanussi ZC 255 AGO User manual

Zanussi

Zanussi ZC 255 AGO User manual

Zanussi ZFT 25 User manual

Zanussi

Zanussi ZFT 25 User manual

Zanussi ZFC 56/38 FF User manual

Zanussi

Zanussi ZFC 56/38 FF User manual

Zanussi ZBA32060SA User manual

Zanussi

Zanussi ZBA32060SA User manual

Zanussi ZRA25100WA User manual

Zanussi

Zanussi ZRA25100WA User manual

Popular Refrigerator manuals by other brands

Frigidaire FRS26TS7DW2 Use & care manual

Frigidaire

Frigidaire FRS26TS7DW2 Use & care manual

Fisher Scientific 10ECEEFSA manual

Fisher Scientific

Fisher Scientific 10ECEEFSA manual

Summit FF22BDRSS user manual

Summit

Summit FF22BDRSS user manual

Frigidaire FFRU17B2QWE use & care

Frigidaire

Frigidaire FFRU17B2QWE use & care

Hotpoint ENBGH 19xxx FW operating instructions

Hotpoint

Hotpoint ENBGH 19xxx FW operating instructions

Hitachi R-SG28KPH instruction manual

Hitachi

Hitachi R-SG28KPH instruction manual

Dometic RMH 7390 L operating instructions

Dometic

Dometic RMH 7390 L operating instructions

AEG S71700TSW0 user manual

AEG

AEG S71700TSW0 user manual

Electrolux ENB3669 Instruction book

Electrolux

Electrolux ENB3669 Instruction book

Electrolux ERN 2930 Instruction book

Electrolux

Electrolux ERN 2930 Instruction book

Beko GNE 60520 X user manual

Beko

Beko GNE 60520 X user manual

Jenn-Air JUR248LBES00 Use & care guide

Jenn-Air

Jenn-Air JUR248LBES00 Use & care guide

Dometic RGE 4000 Installation and operating manual

Dometic

Dometic RGE 4000 Installation and operating manual

Dometic L-0191B Brochure & specs

Dometic

Dometic L-0191B Brochure & specs

LG LRBP1031W - 10 Cu. Ft. Cabinet Depth Bottom Freezer... owner's guide

LG

LG LRBP1031W - 10 Cu. Ft. Cabinet Depth Bottom Freezer... owner's guide

Daewoo RN-33 Series user manual

Daewoo

Daewoo RN-33 Series user manual

Haier RF-8888-174 Service manual

Haier

Haier RF-8888-174 Service manual

Blaupunkt 5CK2 Series user manual

Blaupunkt

Blaupunkt 5CK2 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ZANUSSI
P R O F E S S I O N A L
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
Shelving as accessory
Compressor power - HP 0,5 0,5 0,5 0,5 0,5
Monobloc refrigeration unit
Usable volume - m³ 3,1 4,1 5,1 5,4 6,1
Usable surface area - m² 1,51 2,00 2,50 2,66 2,99
Power supply - V, phases, Hz 220/230 V, 1N, 50 230 V, 1N, 50 230 V, 1N, 50 230 V, 1N, 50 230 V, 1N, 50
Net weight - kg. 281 287 315 330 338
Noise level - dBA 60 60 60 60 60
installed-electric 0.8 0.78 0.8 0.883 0.8
Power - kW
height 2030 2030 2030 2030 2030
depth 1230 1230 1230 1630 1230
width 1230 1630 2030 1630 2430
Internal dimensions - mm
height 2150 2150 2150 2150 2150
depth 1350 1350 1350 1750 1350
width 1350 1750 2150 1750 2550
External dimensions - mm
MN03112CL
102028
MN04112CL
102212
MN05112CL
102217
MN05416CL
102213
MN06112CL
102234
CHARACTERISTICS MODELS
TECHNICAL DATA
RANGE
COMPOSITION
A complete and flexible range of cold rooms
ideal for storing and conserving perishable
food (meat, fish, cold cuts, cheese, fruit,
vegetables), in addition to chilled and frozen
food. Constructed in top quality, reliable
materials, they are manufactured with the
utmost attention paid to eliminting possible
ecological damage. All models can be
connected to a refrigeration unit installed
directly inset on the wall of the cold room or
to a remote refrigeration unit. The availability
of a remote condenser unit is particularly
useful when using cold rooms in
environments with critical ambient
temperatures, ventilation or space problems.
The models detailed on this sheet are 5 cold
rooms (-2°+2°C) with built-in refrigerating
unit and with usable volume of 3,1 to 6,1 m³
with panel insulation 60 mm in thickness. All
models come with panels and gas
precharged cooling unit.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
� Assembly system that guarantees minimal
temperature loss through twin hook fasteners
which allow perfect alignment of the panels.
This fastener is made of high resistant
composite material and guarantees perfect
grip of all components that can be easely
disassembled and reassembled
� Wall panels and inside ceiling panels are
cladded with anti-scratch prepainted
galvanized steel
� All panels are insulated with injected
polyurethane.CFC and HCFC free
� All panels have PVC gaskets foamed in
place to assure airtight and secure fitting.
Any other sealing between panels on site is
eliminated
� Galvanized steel floor covered with a
non-abrasive, non-slip, ribbed plastic coat
� Rounded internal and external corners.
� The right-hinged door is available as
standard (left-hinghed door on request) and
constructed with smooth rounded profiles,
cam-lift action highes, airtight magnetic door,
gaskets and high insulation for saving energy
and operating costs. As an option a
microswitch switches on automatically the
internal light and turns off the fans
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
PRINTER FOR TEMPERATURE
RECORDER
102026 102026 102026 102026 102026
PRINTER FOR HACCP BASIC VERSION
REFRIG.
881457 881457 881457 881457
PLASTIC CURTAIN FOR 65CM DOOR
CLEARANCE
102027 102027 102027 102027 102027
KIT HACCP ADV.CONNECTION FOR COLD
ROOMS
102021 102021 102021 102021 102021
GRAPHIC TEMPERATURE RECORDER 102025 102025 102025 102025 102025
DOOR MICROSWITCH 102441 102441 102441 102441
ALUM.SHELV.,POLY.TIERS-COLDROOM
243X123
137100
ALUM.SHELV.,POLY.TIERS-COLDROOM
203X123
137095
ALUM.SHELV.,POLY.TIERS-COLDROOM
163X163
137091
ALUM.SHELV.,POLY.TIERS-COLDROOM
163X123
137090
ALUM.SHELV.,POLY.TIERS-COLDROOM
123X123
137108
MN03112CL
102028
MN04112CL
102212
MN05112CL
102217
MN05416CL
102213
MN06112CL
102234
ACCESSORIES MODELS
OPTIONAL ACCESSORIES
� Newly designed handle, complete with
lock has an internal safety release to prevent
entrapment when the door is accidentally
locked from outside
� Powerful tropicalized refrigeration system
designed to operate more efficiently and
without failure in the most extreme
temperatures (up to 43ºC)
� Defrosting through heated gas permits to
reduce the total power installed shorten
defrosting time and limited warming of the
cold room
� The control panel includes: luminous
ON/OFF switch, internal lighting switch, cold
room functioning indicator, defrosting cycle
indicator, temperature and thermostat control
with digital display
� All models comply with the standards
required by the main international approval
bodies and are H marked
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
EI - Electrical connection 220/230 V, 1N, 50
MN03112CL
102028
LEGEND
102028
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
EI - Electrical connection 230 V, 1N, 50
MN04112CL
102212
LEGEND
102212
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
EI - Electrical connection 230 V, 1N, 50
MN05112CL
102217
LEGEND
102217
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
EI - Electrical connection 230 V, 1N, 50
MN05416CL
102213
LEGEND
102213
BUILT IN UNIT COLD ROOMS -2º+2ºC
3.1/ 6.1 m³
DEBA01 2010-05-28 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
EI - Electrical connection 230 V, 1N, 50
MN06112CL
102234
LEGEND
102234