Zeiss AxioCam ERc 5s User manual

User Guide
AxioCam ERc 5s
Microscope Camera

2
Carl Zeiss Microscopy GmbH
Carl-Zeiss-Promenade 10
07745 Jena, Germany
www.zeiss.com/microscopy
Carl Zeiss Microscopy GmbH
Königsallee 9-21
37081 Göttingen
Germany
Effective from: 12 / 2015
© Jena 2015 by Carl Zeiss Microscopy GmbH - all rights reserved
This document or any part of it must not be translated, reproduced, or transmitted in any form or by any means, electronic or mechanical, including
photocopying, recording, or by any information or retrieval system. Violations will be prosecuted.
The use of general descriptive names, registered names, trademarks, etc. in this document does not imply, even in the absence of a specific
statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. Software programs will
fully remain the property of ZEISS. No program, documentation, or subsequent upgrade thereof may be disclosed to any third party, unless prior
written consent of ZEISS has been procured to do so, nor may be copied or otherwise duplicated, even for the customer's internal needs, apart from
a single back-up copy for safety purposes.
ZEISS reserves the right to make modifications to this document without notice.
authorized dealer:
Pulch + Lorenz microscopy
Am Untergrün 23, -79232 March
tel: 07665 9272-0
fax: 07665 9272-20
mail: [email protected]
web: pulchlorenz.de

1 About this guide|1.1 Introduction
User Guide AxioCam ERc 5s|V 2.0 en 3
1 About this guide
1.1 Introduction
|
1.1
Introduction
Welcome to the AxioCam ERc 5s user guide.
The camera is a high-resolution digital camera with a color CMOS sensor for light-
microscopy applications. To make it easier for you to set up the camera, please
follow the instructions in these chapters step by step.
Content Chapter Content
About this guide Introduction and overview of this manual.
Safety Important information on the safe handling of the
camera.
Read this chapter before unpacking and
operating the camera.
Shipment The contents of delivery and optional attachments
will be described here.
Technical data Here you will find the camera's technical data.
Connecting the camera In this chapter, you will find detailed instructions
on connecting and using the camera.
Remote Control and OSD
menu
This chapter lists the functions of the IR remote
control and the functions in the On Screen Display
(OSD) menu.
Installing software and
drivers
Here you will learn how to install the software and
camera drivers.
Acquiring images This chapter provides the basics of image
acquisition.
Troubleshooting In this chapter, we have listed some solutions to
various problems. If you are still unable to solve
your problem, contact ZEISS support.
Maintenance This chapter describes some measures for the
maintenance and care of your camera. In case of
greater damage, always contact ZEISS support.
Disposal and Recycling Important instructions for disposal and recycling.

1 About this guide|1.2 Safety notes conventions
4User Guide AxioCam ERc 5s|V 2.0 en
1.2 Safety notes conventions
|
1.2
Safety notes conventions
The safety notes in this document follow a system of risk levels, defined in the
following manner:
CAUTION
Risk of personal injury
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate personal injury.
NOTICE
Risk of property damage
NOTICE indicates a property damage message. In addition, NOTICE is used for
data loss or corrupt data.
Note
Indicates useful additional information. It helps you to make your daily work
easier, but it is optional. There is no risk for personal injury or property damage
involved.

1 About this guide|1.3 Text formats and conventions
User Guide AxioCam ERc 5s|V 2.0 en 5
1.3 Text formats and conventions
|
1.3
Text formats and conventions
Bold texts
Bold is used for texts within the software like names of GUI elements (e.g. buttons,
sections, tools, menus), buttons on a device, and product names (e.g. MTB 2011).
Font type "Courier"
Usedforprogrammingcode,e.g.macrocodeaswellas
foranythingthatyouwouldtypeliterallywhen
programming,includingkeywords,datatypes,constants,
methodnames,variables,classnames,andinterface
names.
Shortcuts and key commands
Shortcuts are written like Crtl+C, meaning you should press Crtl-Key and C-Key
simultaneously.
Procedures
The following formats are used for procedures (instructive sequences):
Prerequisites ¢stands for a condition which must be fulfilled before starting with the action.
Procedure 1stands for a single step the user is asked to perform.
Web-Links
Web links appear in blue text. To open the linked website, simply click on the link.
Please make sure you have an internet connection established before opening the
web link.

2 Safety|2.1 Safety Notes
6User Guide AxioCam ERc 5s|V 2.0 en
2 Safety
2.1 Safety Notes
|
2.1
Safety Notes
The AxioCam ERc 5s has been manufactured and tested by ZEISS according to the
regulations specified in CE and has left the manufacturer’s premises in perfect
working order. In order to ensure that this condition is maintained and to avoid any
risks when operating the system, the user must comply with any notes and
warnings contained in this manual. The manufacturer shall be exempt from
statutory liability for accidents should the operator fail to observe the safety
regulations.
CAUTION
Personal Injury
To avoid personal injury, read and adhere to the safety notes below.
uTo avoid the risk of fire or explosion, do not use the camera near
inflammable liquids or gases.
uSetup, expansions, re-adjustments, alterations, and repairs must be carried
out only by persons who have been authorized by ZEISS.
uDo not allow any cables, particularly power cords, to trail across the floor,
where they can be snagged by people walking past.
uProtect the cables from excessive heat (e.g. halogen lamps, microscope
fluorescence illumination).

2 Safety|2.2 Limitation of liability
User Guide AxioCam ERc 5s|V 2.0 en 7
NOTICE
To avoid equipment damage, data loss, or corrupted data, read and adhere to
the safety notes below.
uProtect the camera against mechanical impact. External damage may affect
the operation of inner components.
uKeep chemicals and fluids away from the camera.
uMake sure there is sufficient ventilation of the camera head. Avoid direct
exposure to sunlight and locations near heat sources (radiators, stoves).
Overheating can cause noisy images.
uUse the camera in a clean and dry location.
uAttach all connectors firmly and securely.
uUse only the accessories supplied by ZEISS, when applicable.
uUse only normal microscope cleaning material to clean the camera housing.
uContact your local ZEISS service organization if a repair is necessary.
uSave all your data, such as images, measurement data, archives, reports,
forms and documents, at regular intervals on an external storage medium.
Otherwise it cannot be avoided that access to this data may be lost as a
result of operational errors or hardware defects. ZEISS accepts no liability for
consequential damage resulting from insufficient data protection.
2.2 Limitation of liability
|
2.2
Limitation of liability
No warranty shall be assumed by ZEISS during the warranty period if the equipment
is operated without observing the safety regulations. In any such case, ZEISS shall
be exempt from statutory liability for accidents resulting from such operation.
2.3 Warranty
|
2.3
Warranty
ZEISS shall be exempt from any warranty obligations should the user fail to observe
the safety regulations. ZEISS only guarantees the safety, reliability, and performance
of the system if the safety notes are closely observed.

2 Safety|2.4 Intended Use
8User Guide AxioCam ERc 5s|V 2.0 en
2.4 Intended Use
|
2.4
Intended Use
NOTICE
The camera should only be used for training and research. The images / videos
from this camera must not be used for the direct generation of diagnostic
results.

3 Technical data|3.1 AxioCam ERc 5s Rev.2
User Guide AxioCam ERc 5s|V 2.0 en 9
3 Technical data
3.1 AxioCam ERc 5s Rev.2
|
3.1
AxioCam ERc 5s Rev.2
Feature Value
Sensor type Micron CMOS color sensor
Number of pixels 2560 (H) x 1920 (V) = 5 megapixels
Pixel size 2.2 µm x 2.2 µm
Chip size 5.70 x 4.28 mm, corresponds to
1/2.5"
Live image frame rates on PC
(maximal values when using optimal
hardware)
H x V: Frame rate @1
ms:
800 x 600 20 fps
Sensor subarea readout (ROI) Adjustable
Digitization 8 Bit / pixel
Exposure times 10 us up to 2 s
Interface (camera) USB 2.0 mini, SD card slot, RJ 45
(LAN), HDMI (DVI-D)
Interface (PC) 2x USB 2.0 Standard-A
Optical interface C-Mount adapter
Dimensions in mm (H x W x D) 66 x 68 x 68
Operating systems Microsoft® Windows 7 x64 Ultimate
SP1, Microsoft® Windows 7 x32
Ultimate SP1
Certificate CE, RoHS
Power supply Via USB 2.0 interface
Environment conditions 5° ... + 45° Celsius, max. 80% relative
air humidity, no condensation, free air
circulation required
Order number 426540-9901-000

3 Technical data|3.1 AxioCam ERc 5s Rev.2
10 User Guide AxioCam ERc 5s|V 2.0 en
Note
Computer hardware, operating system, and software may decrease the frame
rates. Selecting a part of the sensor area or applying binning can increase the
frame rate. All specifications are subject to change without notice.
3.1.1 Spectral Sensitivity
Fig.3.1: Spectral Sensitivity AxioCam ERc 5s

4 Shipment
User Guide AxioCam ERc 5s|V 2.0 en 11
4 Shipment
Content Order No.
1 x AxioCam ERc 5s Rev.2 camera 426540-9901-000
1 x USB 2.0 data Y-cable
1 x DVD with ZEISS software and device driver
Accessory Package
The accessory package is optional. For any use without a PC, the accessory package
is required.
Content Order No.
1 x Power supply with country specific plug adapters 426540-0003-000
1 x SD (SDHC) memory card, 4GB, with protective case
1 x SD card reader
1 x HDMI to DVI cable
1 x IR Remote Control

5 Connecting the camera|5.1 Camera layout and cables
12 User Guide AxioCam ERc 5s|V 2.0 en
5 Connecting the camera
5.1 Camera layout and cables
|
5.1
Camera layout and cables
Camera Connections
Fig.5.1: Camera Connections
1
Fast Ethernet port for communication and image data transfer.
2
HDMI port for image data transfer to a monitor, TV, or projector.
3
(Mini) USB 2.0 port for communication and image data transfer, as well as
power supply.

5 Connecting the camera|5.1 Camera layout and cables
User Guide AxioCam ERc 5s|V 2.0 en 13
Camera Controls
Fig.5.2: Camera controls
1
LED function indicator
2
Capture button (Image / Video)
3
Receiver for IR remote control
4
AWB (Automatic white / gray balance) button
5
Card slot for SD / SDHC memory cards

5 Connecting the camera|5.1 Camera layout and cables
14 User Guide AxioCam ERc 5s|V 2.0 en
Connecting Cables
The following connecting cables are required for voltage supply and use of the
ports:
Name Figure Remarks
USB 2.0 Y cable Connection between camera and PC /
plug-in power supply
USB2.0 cable
(not supplied)
Connection between camera and plug-
in power supply
Plug-in power supply
Output 5 V DC, 1.0 A
(optional)
Power cord
100-240 V
50/60 Hz
HDMI cable
(not supplied)
Connection between camera and
monitor, TV, or projector
HDMI / DVI adapter cable
(optional)
Connection between camera and
monitor / projector
Ethernet cable
(not supplied)
Connection between camera and
network or WLAN router
Note
If the ZEISS Labscope / Matscope app is used, a commercially available WLAN
router is required.

5 Connecting the camera|5.2 Connecting the camera to the mains supply
User Guide AxioCam ERc 5s|V 2.0 en 15
5.2 Connecting the camera to the mains supply
|
5.2
Connecting the camera to the mains supply
Prerequisites ¢The power supply has been adapted with the appropriate country-specific
adapter.
Procedure 1Insert the mini USB plug of the USB 2.0 cable into the mini USB port of the
camera.
2Insert the USB plug of the USB 2.0 cable into the power supply and connect to
a power outlet.
Note
If the USB 2.0 Y cable is used for connection to the mains supply, leave the
second USB plug unused. Using both USB plugs is only required if the device is
to be operated on the PC. In the case of using the camera with a PC, both USB
plugs should be plugged into the PC.
5.3 Connecting the camera to a display (without PC)
|
5.3
Connecting the camera to a display (without PC)
The camera can be connected to a monitor, TV, or projector for visualization of the
live image data. The data at the HDMI output is in DVI format. Further HDMI
functions (e.g. audio, communication between monitor and camera) are not
supported. To enable the display of HD quality, it is recommended that only HD-
capable devices be connected.
Fig.5.3: Connecting the camera to a display / projector

5 Connecting the camera|5.4 Connecting the camera to a network
16 User Guide AxioCam ERc 5s|V 2.0 en
Prerequisites ¢The monitor / projector has been set to 720p60.
Procedure 1Insert the HDMI cable into the HDMI port of the camera (1 and 2).
2Insert the other end of the HDMI cable into the monitor / projector. Secure the
HDMI plug on the jack on the monitor / projector (3).
Note
If the monitor / projector has a DVI port and no HDMI port, an HDMI / DVI
adapter cable or HDMI / DVI adapter will be required for the visualization of
image data (4).
3Set the monitor / projector’s aspect ratio to 1:1 or Aspect. Refer to the
documentation provided by the monitor / projector’s manufacturer.
4For further camera settings using the on-screen display menu (OSD), the
remote control is required, see chapter Remote Control [}18].
5Connect the camera to the mains supply, see chapter Connecting the camera
to the mains supply [}15].
6The camera’s output has a default resolution of 720p60. To set the camera’s
resolution to 1080p30, press the Input button on the remote control, or
change the resolution in the Resolution Menu [}22]. In this case, make sure
the monitor is set to accept a 1080p30 output (refer to monitor / projector’s
documentation from the manufacturer).
5.4 Connecting the camera to a network
|
5.4
Connecting the camera to a network
Prerequisites ¢The camera is powered via the mains power supply, see chapter Connecting
the camera to the mains supply [}15].
Procedure 1Insert the Ethernet cable into the camera’s Ethernet port.
2Insert the other end of the Ethernet cable into a WLAN router.
If you want to use the camera together with the ZEISS Labscope/Matscope app, a
WLAN router will be required. We recommend a high-performance 802.11n WLAN
with sufficient free bandwidth. In the event of an overloaded or slow WLAN, the
live image of the camera may be delayed or incorrectly displayed on the iPad.
Existing WLAN infrastructure may be used or a separate microscope WLAN may be
set up. The camera will identify itself automatically to the network (DHCP) and will
be automatically recognized by Labscope/Matscope, provided the iPad is on the
same network.
For an overview of all ZEISS Microscopy apps and further information on Labscope/
Matscope, visit: http://www.zeiss.com/micro-apps

5 Connecting the camera|5.5 Connecting the camera to a PC
User Guide AxioCam ERc 5s|V 2.0 en 17
5.5 Connecting the camera to a PC
|
5.5
Connecting the camera to a PC
The USB port is for supplying power to the camera and can also be used for data
transfer to the PC. Due to the camera's power requirements, a Y-cable is required
for transferring data to the PC.
Procedure 1Insert the mini USB plug of the Y-cable into the mini USB port on the back of
the camera.
2Insert the two USB 2.0 plugs on the other end of the Y-cable into the PC.
No plug-in power supply is required for operation on the PC.
Note
One USB 2.0 port is not enough to supply power to the camera. If only one plug
is inserted, the camera will not receive sufficient power.
5.6 Function indicator
|
5.6
Function indicator
For the definitions of the LED color signals, refer to the list below:
Signal Description
Green Power supplied
Green flash Cameras start sequence finished; Write to SD card
Red Camera not ready
Red flash Camera error
Off No power supplied

6 Remote Control and OSD menu|6.1 Remote Control
18 User Guide AxioCam ERc 5s|V 2.0 en
6 Remote Control and OSD menu
6.1 Remote Control
|
6.1
Remote Control
Fig.6.1: Remote Control

6 Remote Control and OSD menu|6.1 Remote Control
User Guide AxioCam ERc 5s|V 2.0 en 19
No. Button Standard function Function in OSD menu
1 Menu Activate menu Exit menu
2 On Turn On / Off HDMI
output
Turn On / Off HDMI
output
3 Arrow Up Increase contrast Up / increase value
Arrow
Down
Reduce contrast Down / reduce value
Arrow Left Reduce brightness Left
Arrow Right Increase brightness Right
4 Enter Trigger automatic white
balance
OK (apply value)
5 Capture Capture an image to SD
card
Capture an image to SD
card
6 Live Clear screen of windows Exit menu
7 Index None Go to top tier of menu
8 Record Start / Stop recording
video
Start / Stop recording
video
9 Play Clear screen of windows Exit menu
10 Input Toggle between 720p60
and 1080p30 outputs
Toggle between 720p60
and 1080p30 outputs

6 Remote Control and OSD menu|6.2 On Screen Display Menu
20 User Guide AxioCam ERc 5s|V 2.0 en
6.2 On Screen Display Menu
|
6.2
On Screen Display Menu
To open the On Screen Display (OSD) menu, press the Menu button on the Remote
Control. The OSD menu for adjusting the settings will appear. The following menus
are available for configuring the camera:
6.2.1 Color menu
Fig.6.2: Color menu
Menu entry Description
AWB The purpose of white balance is to calibrate the camera to the color temperature
of the light source used. The AWB function of the camera supports the
Continuous / Push button modes.
In Continuous mode, the white balance is carried out continuously. In certain
samples this may result in incorrect colors.
To ensure that the white balance applies to the light source and not the main
color of the sample, the Push button mode can be set. Here the white balance is
carried out only once if the AWB / Enter button is pressed outside the OSD
menu.
Color Temp. This creates a white balance bias towards yellow (left) or blue (right). If AWB (see
above) is set to Push button, the effect of this regulator is only visible after a
white balance has been carried out with the AWB button (outside the OSD
menu).
Saturation The camera's images are in sRGB color space with an 8 bit color depth per
channel. The color saturation per RGB value can be adjusted.
¢Extreme left: Gray scales
¢Extreme right: Maximum color saturation
Gamma The gamma correction of the camera can be adjusted. Gamma 1 and 0.45 are
available.
Other manuals for AxioCam ERc 5s
2
Table of contents
Popular Security Camera manuals by other brands

Whistler
Whistler WIC-3509P user manual

LifeShield
LifeShield HomeView CMC1000 installation instructions

Panasonic
Panasonic BB-HCM547A Important information

Axis
Axis P3363-VE user manual

Zhejiang
Zhejiang DH-IPC-HFW5421E-Z quick start guide

Panasonic
Panasonic WVBP130 - B/W CCTV CAMERA operating instructions

ZMODO
ZMODO CM-Z2213GY Quick setup guide

Sony
Sony IPELA SNC-DH220 installation manual

UlifeCam
UlifeCam U5820Y installation guide

Vivotek
Vivotek IP8364-C Quick installation guide

Luma Surveillance
Luma Surveillance 310 Series quick start guide

Aigis Mechtronics
Aigis Mechtronics MLA2DN25IR Installation and operating instructions