User and maintenance manual – Translation of original instructions
rigid or metallic tubing. It is also possible to connect the pump to a
polyethylenepipeusinganappropriatefitting.
Itisadvisabletoinstallagatevalveandaflowballcheckvalvetoallow
freepassage.Thisshouldbedoneusingaconnectionpipewithlength
L>5Di(Di=internaldiameterofconnectionpipe) (fig. 3 page 126).
4.2 Installation with a coupling device
Thistypeofinstallationallowseasyremovalofthepumpfromthetank
andquickrepositioningwithoutrequiringinterferanceonthesystem.
4.2.1 Installation with external coupling device (fig. 4 page 126)
Modelswithaverticaldeliverycanbeinstalledwithanexternalcou-
pling device composed of a fixed part and a mobile part.
ThefixedpartisconnectedtothetubingofthesystemusingaDN50
flange or a 2” GAS thread.
Themobilepartisattachedtothepump’sdeliverypipeusinganappro-
priatelysizedpieceofpipe.
Thisdeviceallowstheeasyseparationofthepumpfromthesystem
and, without any intervention in the bottom of the tank, it can be
mountedevenwithoutbeingemptied.
4.2.2 Installation with a bottom coupling device (fig. 5A - 5B page 126)
Thistypeofinstallation,whichisdesignedforpumpswithhorizontal
outlets,allowsthepumptoberemovedfromthetankandrepositioned
inaquickwaywithoutaffectingthesystem.
Formodelswithaverticaloutletwith1½”-2”GASthread,itisnecessa-
rytouseaspecialadaptorkit.
Proceedinthefollowingmanner:
• Attachtheslidingflangetothedeliverypipeonthepumpusingthe
screwsprovidedwiththecouplingdevice;
• Steadilyattachthecouplingdevicetothebottomofthetank;
• Itisrecommendedtoinstallagatevalveandaflowballcheckvalve
toallowfreepassage.Thisshouldbedoneusingaconnectionpipe
withlengthL>5Di(Di=internaldiametreofconnectionpipe)(fig.
6 page 127).
• Affixthecouplingdevicesecurelytobottomofthetank;
• Join the guide tubes to the coupling device and secure them at the
topwiththespacerbracket(suppliedbythemanufacturer)whichwill
ensuretheircorrectparallelalignmentandguaranteethenecessary
rigidityofthesystem;
• Thepumpcanthenbeloweredusingaropeorchainattachedtothe
handle on the upper part of the motor cover. The guide tubes should
beusedtoaidthecouplingoftheflangewiththeoutlettubeofthe
pump until it is affixed to the coupling device.
4.3 Dry or semi-immersed installation (fig. 7 page 127)
Dry or semi-immersed installation is permitted, for pumps without a
coolingjacket,onlywithintermittentperiodicduty(S3mode)according
to the percentage indicated on the metal plaque.
Pumpswith a suction flange canbe coupled tothe systemusing a
curved base plate.
4.3.1 Dry installation with a cooling jacket (fig. 8 page 127)
(only models DGN-DRN-MAN-GRN-APN)
Acoolingjacketallowscontinuousduty(S1)ofthesubmergibleelec-
tricpumpevenwithpartialimmersionorinstalledinadryingchamber.
Thistypeofapplicationcanusethefluidinthetankasacoolingliquid
ifitiscleanenoughandfreefromsolidbodies,orelsewaterfroman
external circuit.
Inbothinstances,thepumpcomessuppliedwithapredisposedsuc-
tion flange for attachment to a curved base plate.
4.3.1.1 Closed jacket cooling system (CC) (fig. 8A page 127)
Owingtotheparticularshapeoftherearpartoftheimpeller,theliquid
inwhichthepumpisimmersedispumpedintothegapbetweenthe
bodyandthejacket,assuringthecoolingofthemotor.Oncethegap
isfilled,theliquidissuckedintothepumpbodythroughapipeandis
then expelled.
WARNING: This system can only be used with clean liquids free
from solid or filamentous particles.
4.3.1.2 Open jacket system cooling (CCE) (fig. 8B page 127)
Thecoolingliquidwhichispumpedintothegapbetweenthebodyand
thejacketcomesfromanexternalpressureunit.
Withthepump,twoattachmentsper“Rilsan”pipeareprovided.Con-
nectthewaterinlet pipe to wherethe“ENTRATA-IN”(fig. 9 page
127)signisattached.Connectthedrainpipetowherethe“USCITA
-OUT”(fig. 9 page 127) sign is attached.
Thetemperatureofthecoolingliquidmustnotexceed40°Cgoinginto
thejacket.
The capacity of the system must be 2-3 l/min and the maximum
pressure must not exceed 0.2 bar.
The cooling circuit must be activated at least 10 seconds before the
pumpisturnedonandnotdeactivatedbeforethecompleteshutdown
of the pump.
5. SUCTION PIPE
Thesuctionpipeofthepumpcanhaveagrillwhichpreventsforeign
bodies larger than the size of the free passage of the pump from en-
tering.
Itisnotrecommendedtoremovethesuctiongrillexceptincaseswhe-
reitisexpresslypermitted.
Periodicallycheckthatthesuctionpipeorthegrillremainfree,withthe
aim of preventing the clogging or blockage of the impeller.
GRmodelshavearotatingknifewiththreebladesthatcutfinesolids
and filaments and prevents the blockage of the impeller.
Periodicallycheckthattheknifeandtheplateoftheshreddingsystem
are free from residues.
Duringcleaningoperationsandmaintenance,alwaysunplugthepump
from power supply. Work with recommended personal protective
equipmentandpaytheutmostattention.
6. ELECTRIC CONNECTIONS (fig. 14 - 15 page 129-130)
All operations connecting the motor pump to the electricity supply
mustbeperformedbytechniciansqualifiedtooperate in areaswith
apotentiallyexplosiveatmosphereandinfullcompliancewithcurrent
regulations.
WARNING: To protect the power supply cable, avoid
twisting, pulling and/or accidental crushing.
Theendsofthepowersupplycablemustbeconnectedtoan
electricpanelcertifiedforuseinpotentiallyexplosiveatmospheresifit
is installed in a hazardous area or to a normal electric panel suitable
fortheatmosphere inwhich it isinstalled if theconnection isfound
tobeinasafearea,alwaysinaccordancewiththeinstallationrules.
In single-phase explosion-proof pumps with a reverse capacitor
and any external capacitor circuit breakers, the capacitors are
included in the supply but they are not connected to the pump
cable as they need to be connected internally to the electric panel
certified for use in potentially explosive atmospheres, if being in-
stalled in a hazardous area.
Beforewiringcheckthat:
• thetensionandfrequencyofthepowerlineareequaltothatindica-
ted on the metal plaque on the pump;
• theabsorbencyindicatedonthemetalplaqueislessthanthemaxi-
mumcurrentsuppliedtothesystem;
• thepowerlineisearthedandhasamagnetothermicdifferentialin
respect to the regulations in force
• theelectriccablesarenotinanywaydamaged.
Alwaysconnectthepumptotheequipotentialearthusingthescrew
onthemotorbody.
The electrical connection phase on models without a plug must be
carriedoutbyfirstconnectingtheyellow-greenearthcableandthen
the other connections.
To protect the pump motor use an adequate overload cutout suited to
theelectricalcharacteristicsshownonthemetalidentificationplaque.
Usinganammeter,checkthattheabsorbencyoftheinstalledpumpis
withinthelimitsindicatedonthemetalpump.
The operation and electrical safety of the ZENIT electric pump are
guaranteedbytheconfigurationprovidedfromthefactory.
WARNING: Anymodifications(e.g.addingapieceofcabletotheori-
ginal) can be considered a deviation of the pump characteristics and
can cause explosions.
6.1 Thermal protection
Allofthe-EXversionsareequippedwithaprotectionsystemagainst
overheating of the engine through means of a bimetal thermal protec-
torwhichdetectsthetemperatureofthepumpwrappingofthestator.
Theendsaremarkedwithastickeruponwhichiswritten“THERMAL
PROTECTION”.
The electric panel must be predisposed to guarantee the shutdown
ofthemotorwhenthethermalprotectionintervenesandtoavoidthe
automaticstart-upofthepumpwhichmustonlybestartedmanually