ZDL-820VCR
Outdoor unit image & dimension
Z DL - 4 V C R Z DL - 6 V C R Z DL - 8 V C R Z DL - 1 0 V CR Z DL - 1 2 V CR
The door station installation avoid sunshine
and water; Camera avoid backlight or the light
of dark place, making
the image more clearly
Night vision illumination distance; more than 2 meters
Gain Control: Automatic
Working temperature: -35-55 ℃
Resolution: High Definition CCD Camera 480TVL
Intensity of illumination: 0.01Lux
Camera angle: 92 degrees wide-angle
295mm
103mm
335mm
1 2 5 m m
295mm
16
48
48
Size:335(L) x 125(W) x 64(H)mm
Embedded size:9 2 5(L) x 103(W) x 48(H)mm
Adjustment of the camera degree
Password restore factory settings--No.4
Display mode settings
Calling volume adjustment
Wire out slot
Microphone
Infrared rays supplement light LED
Number reveal screen
Standard number keyboard
# (password) button
Speaker
Camera
X (clear) button
Functions and settings of outdoor unit
Password setting(factory system password:2000)
1. Setting the unlock password (Unlocking password can be set 999 group).
When the host is in standby mode, lnput the system password:2000 and then pressing”#” key
(host display PPPP), Entering group password <XXXYYYY>,and then Pressing”#”, Host display
<DONE>,Host XXX group unlocking password is set by YYYY,<XXX> is the password group number,
<YYYY> is unlocking password; X, Y an arbitrary number. But<XXX>cann’t be<000>;<YYYY>cann’t
be consistent with the current master password.
Example: Setting the password: #2000# 001 1234# password: #1234#
2. Change the system password
When the host is in standby mode, Input the system password: 2000, and then Pressing”#”key
(host display PPPP), Entering group password <000NNNN>, and then Pressing”#”,Host display
<DONE>, The password is changed “NNNN”(N is arbitrary number)
Example: Change the system password:#2000# 000 3333# that is replaced system password:
3333
3. Cancel the single unlocking password
When the host is in standby mode, Input the system password: 2000, and then pressing “#”key
(host display PPPP), Entering group password<XXX>, and then pressing”#”, Host display<DONE>,
The XXX group unlocking password has been canceled.
Example: # 2000# XXX#(Single password has been canceled)
4. Cancel all unlocking password
Connecting with the< >on the back of the door station PCB, And then pressing long-time< >
<PASSWORD> key, digital tube displayed< >, and then removing< > its short-circult cap,
Firstly power-off, And then power-on, All the setting password will be cleared.
5.The system password initialization setting
Pull-back< >to “ON” key on the back of the door station PCB, And then pressing
long-time< ><PASSWORD> key, digital tube displayed < >, And then press
< >back to<3>, Firstly power-off, And then power-on, The system password is 2000.
1 2
ZDL-820VCR