ZHUDELE ZDL Series User manual

RoHS
RoHS
zhuhai@zhudele.com
www.zhudele.com

ZDL-820VCR
Outdoor unit image & dimension
Z DL - 4 V C R Z DL - 6 V C R Z DL - 8 V C R Z DL - 1 0 V CR Z DL - 1 2 V CR
The door station installation avoid sunshine
and water; Camera avoid backlight or the light
of dark place, making
the image more clearly
Night vision illumination distance; more than 2 meters
Gain Control: Automatic
Working temperature: -35-55 ℃
Resolution: High Definition CCD Camera 480TVL
Intensity of illumination: 0.01Lux
Camera angle: 92 degrees wide-angle
295mm
103mm
335mm
1 2 5 m m
295mm
16
48
48
Size:335(L) x 125(W) x 64(H)mm
Embedded size:9 2 5(L) x 103(W) x 48(H)mm
Adjustment of the camera degree
Password restore factory settings--No.4
Display mode settings
Calling volume adjustment
Wire out slot
Microphone
Infrared rays supplement light LED
Number reveal screen
Standard number keyboard
# (password) button
Speaker
Camera
X (clear) button
Functions and settings of outdoor unit
Password setting(factory system password:2000)
1. Setting the unlock password (Unlocking password can be set 999 group).
When the host is in standby mode, lnput the system password:2000 and then pressing”#” key
(host display PPPP), Entering group password <XXXYYYY>,and then Pressing”#”, Host display
<DONE>,Host XXX group unlocking password is set by YYYY,<XXX> is the password group number,
<YYYY> is unlocking password; X, Y an arbitrary number. But<XXX>cann’t be<000>;<YYYY>cann’t
be consistent with the current master password.
Example: Setting the password: #2000# 001 1234# password: #1234#
2. Change the system password
When the host is in standby mode, Input the system password: 2000, and then Pressing”#”key
(host display PPPP), Entering group password <000NNNN>, and then Pressing”#”,Host display
<DONE>, The password is changed “NNNN”(N is arbitrary number)
Example: Change the system password:#2000# 000 3333# that is replaced system password:
3333
3. Cancel the single unlocking password
When the host is in standby mode, Input the system password: 2000, and then pressing “#”key
(host display PPPP), Entering group password<XXX>, and then pressing”#”, Host display<DONE>,
The XXX group unlocking password has been canceled.
Example: # 2000# XXX#(Single password has been canceled)
4. Cancel all unlocking password
Connecting with the< >on the back of the door station PCB, And then pressing long-time< >
<PASSWORD> key, digital tube displayed< >, and then removing< > its short-circult cap,
Firstly power-off, And then power-on, All the setting password will be cleared.
5.The system password initialization setting
Pull-back< >to “ON” key on the back of the door station PCB, And then pressing
long-time< ><PASSWORD> key, digital tube displayed < >, And then press
< >back to<3>, Firstly power-off, And then power-on, The system password is 2000.
1 2
ZDL-820VCR

Microphone
Haut-parleur
Power Indicator
Unlock Indicator
Photo Indicator
Unlock
Monitor / Talk
Inside the intercom
Alarm
Call Administrator
Functions and settings of indoor monitor
Ring adjust
Brightness adjust
Chroma adjust
Speaker adjust + -
- +
SPK
MIC
ZDL-TFT2700W ZDL-TFT6680W
ZDL-TFT371W ZDL-TFT6700X
ZDL-TFT6700B
ZDL-TFT027
1 2 3
4 5 6
Indoor phone room NO. setting:
The room number by the four-digit form, according with 1000, 100, 10, 1 digit sequence, Pressing
" " key when extension standby mode over 5 seconds, after warning tone release. Pressing
" " key, enter the extension number of 1000 digit, Pressing 1 time " " key, 1000 digit display1,
Pressing key 2 times " " key, 1000 digit display 0. There have 2, followed by analogy, if 1000 digit
display 0; Directly pressing" " key to confirm, 1000 digit display 0. There have 2 short warning tone.
In accordance with the above steps, followed analogy by input the extension number of 100 digit,
10 digit and 1 digit. Extension number input is completed, there is a warning tone, Indicating an effective
setting.
Example: A room number is 2013, Pressing a long time " " key loosely after 5 seconds. Pressing
" " key twice times, Pressing " " twice times. Pressing " " key one time, Pressing " ",
Pressing " " key thrice times, Pressing " " one time.
There are 12 chord ring tones, the way how to select as follows:
Indoor unit standby, pressing a long time" " key loosely after 5 seconds, it will play the current set
ring tone, then pressing the" " key each times, it will play the next one ring tone, if confirmed that one
you like, just pressing " " key for confirmed or you can let the ring tone goes until 10 seconds later,
system will default to set this ring tone.
Notes:
Pressing button each time, indicates that the key to be valid. Each keystroke time interval should be
less than 10 seconds, otherwise it will return a static. Factory extension number defaults: "1111 "
ZDL-TFT6380W
3 4
7"
7" 7" 7"
8.3" 8.3"
Indoor monitor image & dimension

6S 4S
1234567
J1
J2
J3
V1、V2、V3、V4、V5、V6、V7
V9 ( Connection to the decoder ZDL-980H4 )
Video cable which connect to outdoor unit
Video output port
+ - 2 3 4 5 6
+-2345
+-23456
+-2345 +-2345 +-2345
+ - + - + -+ -
-
+-
+
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
GAIN
Error indicator
Discharge
Indoor 4 Indoor 3 Indoor 2 Indoor 1
The strength of the LED
light shows video good or
bad effects
H1
J2
The way of setting up outdoor
units quantity
2-7pcs outdoor units
ZDL-980H2
J3
J4
J2 J4 short-circuit video buffered output
J3 short-circuit video amplification output
4 Channel protector setting
ZDL-980H4
When monitors’positive and negative power is being short circuit, fuse will burned, in order
to protect the entire system.
After the installation , this light will turn off in 30-60 seconds, if it still turns on after 60 seconds,
it means the connection is wrong.
5 6
Outdoor unit
QTY
Adjust the screen effect, the users of
indoor monitors are more than 200.
Power LED
160mm
Notes for installing.
Please keep the product away from magnetism, severe moisture,
direct sun rays and nearby heater, which may influence on the product.
Suitable height for main unit is 1600mm from the bottom to the screen.
Please arrange the handset after installation is completed.
Please refer to (Camera setup) regarding the installation of camera units.
Functions and settings of indoor monitor
Unlock
Monitor
Inside the intercom
Chroma adjust
Chroma adjust
Brightness adjust
+
Camera station selector setting

+-23456
+-2345
+-23456
+-2345 +-2345 +-2345
E-lock
Protector
Z D L - 9 8 0 H 4
- + - + - +- +
1 8 V +
1 8 V -
-
+-
+
123456789
Z D L -820VCR
ZDL-TFT371W
Indoor 4
Indoor 3 Indoor 2 Indoor 1
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
+-23456
+-2345
+-23456
+-2345 +-2345 +-2345
Protector
Z D L - 9 8 0 H 4
- + - + - +- +
-
+-
+
Indoor 4
Indoor 3 Indoor 2 Indoor 1
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
Power wire:
RVV2 × 0.5mm
Unlocking wire:
RVV2 × 0.5mm
RVV6× 0.3mm
SYV75-3
Signal wire:
RVV6 × 0.5mm
Video wire
SYV75-5
To next floor Video wire
SYV75-5
Video wire
Signal wire RVV6× 0.5mm
SYV75-5 (SYV75-3)
1 (Video +)
2 (Video -)
1 V i d e o +
2
3 D e c o d e ( a u d i o
4 C o n t r o l ( U n l o c k i n g )
5 C a l l m a n a g e m e n t c e n t r e
6 D C 1 8 V +
7
8 L o c k +
9
V i d e o - ( G N D )
)
D C 1 8 V-
L o c k -
Indoor unit
DC18V+
DC18V-
Video - (GND)
)
Three-way calling
SOS
1 Video +
2
3 Decode (audio
4 Control (Unlocking)
5 Call management centre
6
Connect to the outdoor unit
Connect to the outdoor unit
Connect to the outdoor unit
Connect to the outdoor unit
R1 1
R2 2
R3 3
R4 4
L+ Lock+
R 1
R 2
R 3
R 4
L +
ZDL-TFT371W
Visual building intercom layout drawing
7 8
Package configuration
Picture
ZDL-820VCR
Model
1
QTY
ZDL-TFT2700W
ZDL-980H4
ZDL-PS18
ZDL-1079
ID card
20
(1-9999)
1
100
Picture Picture
ZDL-4VCR ZDL-6VCR
Model Model
1 1
QTY QTY
ZDL-TFT2700W ZDL-TFT2700W
ZDL-980H4 ZDL-980H4
ZDL-PS18 ZDL-PS18
ZDL-1079 ZDL-1079
ID card ID card
4 6
1 2
1 1
1 1
100 100
Picture
ZDL-8VCR
Model
1
QTY
ZDL-TFT2700W
ZDL-980H4
ZDL-PS18
ZDL-1079
ID card
8
2
2
1
100
Picture Picture
ZDL-10VCR ZDL-12VCR
Model Model
1 1
QTY QTY
ZDL-TFT2700W ZDL-TFT2700W
ZDL-980H4 ZDL-980H4
ZDL-PS18 ZDL-PS18
ZDL-1079 ZDL-1079
ID card ID card
10 12
3 3
2 2
1 1
100 100
5
(1-250)
2
(+20 Monitors)
(+1 PS18)

Visual building intercom layout drawing Visual building intercom layout drawing
+-23456
+-2345
+-23456
+-2345 +-2345 +-2345
Protector
Z D L - 9 8 0 H 4
- + - + - +- +
1 8 V +
1 8 V -
-
+-
+
1 2 3 4 5 6 7 8 9
Indoor 4
Indoor 3 Indoor 2 Indoor 1
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
+-23456
+-2345
+-23456
+-2345 +-2345 +-2345
Protector
Z D L - 9 8 0 H 4
- + - + - +- +
-
+-
+
Indoor 4
Indoor 3 Indoor 2 Indoor 1
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
Power wire:
RVV2 × 0.5mm
Unlocking wire:
RVV2 × 0.5mm
RVV6× 0.3mm
SYV75-3
Signal wire:
RVV6 × 0.5mm
Video wire
SYV75-5
To next floor Video wire
SYV75-5
ZDL-TFT2700W
Unlocking Power
ZDL-PS12
7 C O N TR OL
6 C O N TR OL
5 P U S H
4 + 1 2 V
3 GN D
2 NO
1 NC
-
+
Electric-plug lock
Magnetic lock
OR
Outdoor button
ZDL-TFT2700W
Z D L -820VCR
Host selector
ZDL-980H2
+-23456
+-2345
+-23456
+-2345 +-2345 +-2345
Protector
ZDL-980H4
- + - + - +- +
-
+-
+
1 2 3 4 5 6 7 8 9
Indoor 4
Indoor 3 Indoor 2 Indoor 1
VIDEO POW VIDEO VIDEO VIDEOPOW POW POWPOW
V-OUT
V-IN
ZDL-TFT2700W
To next floor Video wire
SYV75-5
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
+
-
Power wire:
RVV2 × 0.5mm
E-lock
Unlocking wire:
RVV2 × 0.5mm
+
-
Power wire:
RVV2 × 0.5mm
E-lock
Unlocking wire:
RVV2 × 0.5mm
+
-
Power wire:
RVV2 × 0.5mm
E-lock
Unlocking wire:
RVV2 × 0.5mm
1 2 3 4 5 6 7 8 9
+
-
Power wire:
RVV2 × 0.5mm
E-lock
Unlocking wire:
RVV2 × 0.5mm
9 10
Unlocking time

R
ADDRESS ADDRESS
N
Add the management card:
Power-off, The S2 plug into1, 2-Terminal, Power-on,Red & Green LED lights flash
alternately, Swipe Continuously two cards, The green light flash to add successfully;
Power-off, The S2 plug into2,3-Terminal, And then power-on. (Swipe the first card is
adding a”Add card”, Swipe the second card is adding a”Delete card”).
Add the user card:
Swipe the added management card in working state, The green light flashes,
Swipe added user card (1 pcs or more)
Swipe the added management card successfully to exit at last.
Delete user card:
Swipe the deleted management card in working state, The red light flashes,
Swipe needed deleted user card. Swipe the deleted management card
successfully to exit.
Delete all cards:
Swipe the delete management card in working state, The red light flashes,
And then Swipe added Management card, Swipe the deleted management
card confirm deleting.
The green light I restore after waiting for 5S, Delete successfully.
ID card setting Warning
11 12

General fault identify & remove
Failure phenomenon Exclusion method
No sounds during intercommunication. Confirmed it is one user or the whole system
Check the 3 line connection.
Lose unlocking functions. Check the 4 line, whether it offer 10V power when
pressing the unlock button.
Whether L+ L- offer 12V power out to the e-lock.
Whether the electric lock coil is damaged.
Image bobbing up and down. Video are not synchronized, adjust the potentiometer.
Image appears bars. Image signal is weak lead out of sync.
Check whether the video cable is in good connection,
whether the transmission distance is too far,
whether the wire is in the standard
Adjust the monitor‘s potentiometer or video zoom,
gain potentiometer.
The outdoor unit cannot
contact to the indoor monitor.
Pressing the monitoring button ,check whether
appear images.
If appear Image and communicate good, check
whether room number is set correctly.
If cannot appear Image and without communicate,
check the connection line of 3.
Out door unit or indoor monitor damage
If appear Image but without communicate. Confirmed it is one user or the whole system
Check the 3 line connection.
One user: check the monitor and its connection line of 3.
Image blurred, dim. Signal is too weak, the impedance does not match or
contrast is not good.
Adjust the video amplifier and the gain potentiometer.
If the contrast or brightness is not good , adjust the
potentiometer to improve the image effect.
The image is sometimes clear,
sometimes fuzzy.
Is it the video connector firm
If monitor‘s brightness, contrast potentiometer loose,
replace it .
Image ghosting. Check the video cable is connected right (video line
must be connected in series).
Check whether there are sources of interference.
Images do not appear on the monitor. Whether it can intercom.
Check the video line or replace the camera.
Check whether the outdoor unit has power in, check
on the 4th line or the outdoor unit.
When intercommunication ,
it buzzers.
Whether power supply is good.
Check whether there are sources of interference.
System is busy, the red indicator lights. Check the source of the 4th line on the ground voltage
(6.5V or 10V ).
Whether the outdoor unit or indoor monitor is normal.
13
This manual suits for next models
6