ZKTeco ProFace X User manual

Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the
actual product and the written information in this manual.
Quick Start Guide
ProFace X [TI]
Version: 1.0

1
1 Overview
8-inch Touchscreen
Camera & Palm Modules
Speaker
Reset Button
Flash
Exit
button
Auxiliary
input
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
Alarm
Lock
Sensor
+12V Power
GND
INWD0
INWD1
Wiegand
In
Wiegand
Out
12V
GND
WD0
WD1
Network interface
RS232
RS485
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Power
interface
Tamper Switch
Near-infrared Flash
Thermal Imaging Temperature
Detection Module
Microphone (Optional)

AVOID DIRECT
SUNLIGHT
EXPOSURE
INDOOR USE
KEEP DISTANCE AVOID GLASS
REFRACTION
10ft
6.5ft
window
2
2 Installation Requirements
The installation requirements and indicators associated with temperature detection are given below:
Specification Standard Value Remark
Operating
Environment
Distance
(between face
and device)
Measurement
Accuracy
Indoor, No wind, No direct light,
16°C to 35°C(60.8°F to 95°F)
30 to 120cm (0.98ft to 3.94ft)
±0.3°C(±0.54°F)
The recommended operating
temperature is 25°C(77°F)
The recommended distance
is 80cm (2.62ft)
This Value is tested at a distance
of 80cm or 2.63ft in 25°C or
77°F environment.
Notes: The temperature detection data is for reference only, and not for any medical purpose.
Forehead Temperature Detection
Installation height: 1.55m
FOV (field of view) of the thermal
imaging device:50°
Temperature measurement
distance: 0.3m to 1.2m
Height of the face adapted for
detection: 1.2m to 2m
Installation Environment:
155CM
Indoor constant Temperature
Environment

3 Device Installation
①
②
3
① Attach the mounting template sticker to the wall, and drill holes according to the mounting
paper.
② Fix the back plate on the wall using the wall mounting screws.
③ Attach the device to the back plate.
④ Fasten the device to the back plate with a security screw.
Installation on the wall
1 2
4
1.55m
3

Installation on the barrier gate
Please pass the wire through the bracket before installation.
① Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut.
② Adjust the angle of the device.
3 Device Installation
1
2
①
②
4

4 Standalone Installation
Alarm Smoke
detector
Lock TCP/IP
Exit button
Door sensor
Reader
PC
5 Door Sensor, Exit Button & Alarm Connection
Door sensor
Alarm power
Alarm
-
+
-+
-+
-+
Detector power
Smoke detector
Exit button
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
GND
5

6 Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally unlocked when the power is on) is connected with 'NO' and 'COM' terminals,
and the NC LOCK (normally locked when the power is on) is connected with 'NC' and 'COM' terminals.
Take NC Lock as an example as shown below:
1) Device not sharing power with the lock
Normally Closed Lock
DC12V
DC12V
2) Device sharing power with the lock
+12V
GND
FR107
FR107
Normally Closed Lock
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
DC12V +12V
GND
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
7 Wiegand Reader Connection
Access Controller
+12V
GND
Wiegand Reader
INWD0
INWD1
12V
GND
WD0
WD1
Maximum input is 30V 3A
6

8 Barrier Connection
9 RS485 Connection
+12V
GND
GND
485+
485-
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
485 reader
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot
be connected to the gate and reader at the same time.
7

11 Ethernet Connection
Connect the device and the system over an Ethernet cable. An example is shown below:
: 192.168.1.201Default IP Address
: 255.255.255.0 Subnet mask
: 192.168.1.130IP Address
: 255.255.255.0 Subnet mask
Note: In LAN, IP Addresses of the server (PC) and the device must be in the same network segment
when connecting to the ZKBioSecurity MTD software.
Click [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
10 Power Connection
Recommended power supply: 12V - 3A
To share the power with other devices, use a power supply with higher current ratings.
12V 3A DC
8

12 User Registration
Method1: Register on the device
Click > [User Mgt.] > [New User] to register a new user. The settings include entering the User ID
and Name, registering palm, face, password and user photo, setting user role and access control role.
When there is no Super Administrator set in the device, click to enter the menu. After setting the
Super Administrator, the system will request for the administrator’s verification before entering the menu.
For security purpose, it is recommended to register a Super Administrator at the first time you use
the device.
Palm Registration
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
L
User Mgt.
New User
All Users
Display Style
Enroll Face
Enrolled Successfully
3
0
0
*****
New User
User ID
Name
User Role
Palm
Face
Password
User Photo
Access Control Role
Normal User
0
L
9

Refresh New Delete Export Search Device Device Control Set up View and Get Device Info Communication
Search Device
Search No device found? Download Search Tools to Local Disk
Total Progress
IP Address
IP Address
Device Type Serial Number
Searched devices count:2
Number of devices added:1
MAC Address Subnet Mask Gateway Address Serial Number Device Type Set Server Operations
192.168.0.31 255.255.255.0 192.168.0.1 SpeedFace-H5L This device has been added
Add
192.168.10.214 255.255.255.0 192.168.1.1
XXXX000000000
XXXX000000000 ProFace X
The current systen communication port is 8088, please make sure the device is set correctly.
Step 1
Step 2
Step 3
Add
Clear Data in the Device when Adding
Device Name *
Icon Type*
Area*
Add to Level
192.168.4.18
Door
Area Name
[Clear Data in the Device when Adding] will delete data in the device (except event
record), please use with caution!
OK Cancel
Step 4
Method 2: Register on the ZKBioSecurity MTD Software
Please set the IP Address and Cloud Service Server Address on the device.
2. Click [Personnel] > [Person] > [New] to register users in the software.
3. Add users to access levels.
4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices].
For more details, please refer the ZKBioSecurity MTD User Manual.
1. Click [Access] > [Access Device] > [Device] > [Search Device] to add the device to the software.
When the server address and port are set, it can be added automatically.
10

Position
Dismissed Personnel
Card Management
Personnel ID Name
The current query conditions None
Refresh Delete
Personnel ID First Name Last Name Mobile Phone Status Create Time Operations
Delete4835 Mike
1-1 50 rows per page Jump To 1 /0 Page Total of 0 records
Welcome, admin
Method 3: Register on the phone
2. The users will be displayed in [Personnel] > [Temporary Personnel], click [Review].
Once the ZKBioSecurity MTD software is installed, users could enroll their face via browser application on
their own mobile phone.
1. Click [Personnel] > [Parameters], input ‘’http://Server address:Port’’ in the QR Code UGL bar. The
software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server
address:Port/app/v1/adreg’’ by the mobile phone to register the users.
Personnel Registration
Personnel Registration
Personnel ID
First Name
Last Name
Last Name
Mike
4835
Position
Dismissed Personnel
Personnel ID Setting
The Maximum Length:
Support Letters:
Personnel ID Auto-increment:
Yes No
Yes No
15
Card Setting
The Maximum Length:
Card Format Display:
Bits(Binary)
Decimal Hexadecimal
32
Yes No
Multiple Cards per Person:
Temporary Personnel Setting
Enable Temporary Personnel Auto-audit: Yes No
Self-service Registration
QR Code URL: http://Server address:Port
Download QR code image
Yes No
Enable the declaration of health information:
Card Management
11

Click > [Comm.] > [Ethernet] to set the network parameters. If the TCP/IP communication of the
device is successful, the icon will be displayed in the upper right corner of the standby interface.
Click that is, the IP > [Comm.] > [Cloud Server Setting] to set the server address and server port,
address and port number of the server after the software is installed. If the device communicates with
the server successfully, the icon will be displayed in the upper right corner of the standby interface.
13 Ethernet and Cloud Server Settings
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
192.168.163.150
0.0.0.0
4370
255.255.255.0
192.168.163.1
IP Address
Subnet Mask
Gateway
DNS
TCP COMM. Port
DHCP
Display in Status Bar
Ethernet
Note:
When using the ZKBioSecurity MTD software, make sure that the option Enable Domain Name is
disabled and input the correct server address and port.
Server Address: Set the IP address of the ZKBioSecurity MTD server.
Server Port: Set the service port of ZKBioSecurity MTD (The default is 8088).
14 Access Control Settings
Click to enter the access control management interface and set the relevant > [Access Control]
parameters of access control.
ADMS
8081
0.0.0.0
Server mode
Enable Domain Name
Server Address
Server port
Enable Proxy Server
Cloud Server Setting
HT TPS
12

Access Control Options
Time Rule setting
Holidays
Combined Verification
Anti-passback Setup
Duress Options
Access Control
Gate Control Mode
Door Lock Delay (s)
Door Sensor Delay (s)
Door Sensor Type
Verification Mode
Door available time period
Normal open time period
Master Device
Auxiliary input configuration
Speaker Alarm
Reset Access Setting
Access Control Options
5
15
None
Password/Face/Palm
1
None
Out
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
15 Records Query
Click > [Attendance Record] to open the records query interface, input > [Attendance Search]
the user ID and select the time range, the corresponding attendance logs will be displayed.
Attendance Record
Attendance Photo
Blocklist ATT Photo
Attendance Search
03-03
03-04
03-05
4
2
3
1
3
2
4
1
4
3
2
Personal Record Search
Date User ID Access records
Number of Records:04
11:25
11:25 11:22
11:25
11:29
11:29 11:21
11:28
11:26
11:27
11:27
11:27
11:27
Number of Records:04
Number of Records:04
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
13

Temp. Unit ℃
Temperature measurement distance Far
Display Thermodynamics Figure
Display Body Temperature
Enable mask detection
Deny access without mask
Allow unregistered people to access
Enable capture of unregistered person
Trigger external alarm
Clear external alarm
Exter alarm delay(s) 255
Firmware update
Detection Management
37.3
0.00
Enable temperature screening with infrared
High temperature alarm threshold
Temperature over the range; access denied
Temperature deviation correction
Temp. Unit
Temperature measurement distance
Display Thermodynamics Figure
Display Body Temperature
Enable mask detection
Deny access without mask
Allow unregistered people to access
Enable capture of unregistered person
Detection Management
Far
OC
OC
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
16 Detection Management Settings
L
Click System Detection Management enter the setting interface > [ ] > [ ] to .
You can set the value of High temperature alarm threshold, enable the Temperature over
the range; access denied and the Trigger external alarm. The device will send an alarm prompt
when the temperature of the detected user exceeds this value, meanwhile the user will be denied
access, as shown in the following figure. The method of enabling Mask detection is the same.
When the Allow unregistered people to access is enabled, optionally, set Enable capture of
unregistered person to save the temperature data.
14
08:50
Failed to verify.
Verify:Face
User ID:4835
Without mask
High body temperature
O
Temp.: 38.6 C
08:50
Successfully verified.
Name:Mike
User ID:4835
Verify:Face
Normal temperature
O
Temp.: 36.6 C
Mask Detected
❶
❷

1. The effective distance for temperature detection is within 1.2m.
2. Recommended for indoor use only.
3. The temperature detection data is for reference only, and not for any medical use.
4. Remove the mask to register the face, and wear the mask to recognize the face. The type of mask,
face area covered by the mask, and bangs will affect the facial recognition effect.
5. Facial verification for masked individuals will increase the FAR(False Acceptance Rate). Palm verification
for masked individuals is recommended.
Note:
Once the ZKBioSecurity MTD software installed, users could perform temperature detection
management on browser.
Real-time monitoring on softwareZKBioSecurity MTD
Effective distance
Effective distance:
Temperature: 0.3 to1.2m
Face : 0.3 to 2.5m
1. Please set the IP Address and Cloud Service Server Address on the device and add the device to the
software.
2. Click [Temperature Detection] > [Temperature Management] > [Real-time monitoring] to view all
the events including Abnormal Temperature, No Masks and Normal Records.
When the Temperature setting has been set, the user data of abnormal body temperature will be
displayed on the abnormal temperature information bar automatically.
3. Click [Temperature Management] > [Statistics Panel] to view the analysis of statistical data and the
personnel with normal temperature as shown in the following figure.
15

For more details, please refer the ZKBioSecurity MTD User Manual.
Welcome, admin
Real-Time Monitoring
Total:217 20 150 61
Abnormal Temperature Normal Records
No Masks
None
Temperature:
Name:
Department:
Time:
36.65
UnregisterUser
NULL
14:42:00
Temperature:
Name:
Department:
Time:
36.65
UnregisterUser
NULL
14:42:00
Temperature:
Name:
Department:
Time:
36.65
UnregisterUser
NULL
14:42:00
Temperature:
Name:
Department:
Time:
36.65
UnregisterUser
NULL
14:42:00
None None None
Name:
Department:
Temperature:
Mask:
Time:
UnregisterUser
NULL
36.57
Yes
15:01:39
Name:
Department:
Temperature:
Mask:
Time:
UnregisterUser
NULL
36.57
Yes
15:01:39
Name:
Department:
Temperature:
Mask:
Time:
UnregisterUser
NULL
36.57
Yes
15:01:39
2020-05-28 11:03:07
Temperature
Real-Time Monitoring
Statistics Panel
Temperature Raw Record
Personnel Temperature
Schedule
Abnormal Temperature
Record
Departmental body
temperature daily statistics
report
Parameters
Monthly Event Statistics
Report
o
40.1 C
Mask:
Name:
Department:
Time:
None
(19961107)
null
09:50:48
o
40.1 C
Mask:
Name:
Department:
Time:
None
(19961107)
null
09:50:48
o
40.1 C
Mask:
Name:
Department:
Time:
None
(19961107)
null
09:50:48
o
40.1 C
Mask:
Name:
Department:
Time:
None
(19961107)
null
09:50:48
Statistics
Time Today
The current query conditions None
Refresh
ViewNormal temperaturePeople
Per sonnel ID Department Name
The current query conditions None
Refresh
Personnel ID First Name Department
Number
Department Name
3 1 Sales
Temperature abnormal
Normal temperature Temperature abnormal
Unmeaured body temperature
1-2 50 rows per page Jump To 1/1 Page
2 1 Sales
Welcome, admin
Temperature
Real-Time Monitoring
Statistics Panel
Temperature Raw Record
Personnel Temperature
Schedule
Abnormal Temperature
Record
Departmental body
temperature daily statistics
report
Parameters
Monthly Event Statistics
Report
Normal temperature
Unmeaured body temperature
Total of 4 records
16

17 Palm Enrollment Procedure
17
30-50cm
1. Place your palm within 30-50cm from the device.
2. Place your palm in the palm detection area, such that the palm is placed parallel to the device.
3. Make sure to keep space between your fingers.