WARNINGS
•Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even
death.
•The appliance is intended for a specifi c pool use and must not be used for any use other than that for which it was
designed.
•It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) people
who have previously received the instruc ons for use. All persons not mee ng these criteria must not approach the
appliance in order to avoid exposure to dangerous elements.
•Keep the appliance out of the reach of children.
•The device must be installed by a qualifi ed technician according to the manufacturer’s instruc ons and in compliance
with local regula ons. The installer is responsible for installa on of the equipment and for compliance with na onal
installa on regula ons. Under no circumstances can the manufacturer be held liable in the event of failure to
comply with applicable local standards.
•Incorrect installa on and/or use may cause serious damage to property or serious injuries (possibly causing death).
•All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee shall make
reserva ons in wri ng on the carrier’s bill of lading if damage is detected, caused during transport (confi rma on to
be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). In the event of a device
containing coolant that has been turned on its side, men on your reserva ons in wri ng to the carrier.
•If the appliance suff ers a malfunc on, do not try to repair the appliance yourself, contact a qualifi ed technician.
•Refer to the warranty condi ons for details of the permi ed water balance values for opera ng the appliance.
•Elimina ng or shun ng one of the safety devices automa cally voids the warranty, as does the replacement of parts
using parts not manufactured by ourselves.
•Do not spray insec cide or any other chemical (infl ammable or non-infl ammable) in the direc on of the appliance,
as this may damage the body and cause a fi re.
•Heat pump, fi ltra on pump and fi lter appliances are compa ble with all types of water treatment.
•For heat pump appliances or dehumidifi ers, do not touch the fan or insert a rod or your fi ngers through the gra ng
when the appliance is in opera on. The fan rotates at high speed and may cause injuries or even death.
•The electrical supply to the appliance must be protected by a dedicated 30 mA diff eren al residual current protec on
device, complying with the standards and regula ons in force in the country where it is installed.
•Means for disconnec on from the supply mains having a contact separa on in all poles that provide full disconnec on
under overvoltage category III, must be incorporated in the fi xed wiring in accordance with the wiring rules.
•Before carrying out any opera ons, check that:
- The voltage indicated on the maker’s plate of the appliance corresponds to the mains voltage,
- The power grid is adapted to the power requirements of the appliance, and is grounded.
- The plug (where applicable) is suitable for the socket.
•In the event of abnormal func on or the release of odours from the appliance, turn it of immediately, unplug it from
its power supply and contact a professional.
•Before any interven on on the appliance, ensure that the la er is switched off and disconnected from the power
supply, in addi on to any other equipment connected to the appliance, and that the hea ng priority (where
applicable) is deac vated.
•Do not disconnect and reconnect the appliance to the power supply when in opera on.
•Do not pull on the power cord to disconnect it from the power supply.
•Do not handle the electrical elements with wet hands.
•Clean the terminal board or the power supply socket before connec on.
•For any component or sub-assembly containing a ba ery: do not recharge or dismantle the ba ery, or throw it into
a fi re. Do not expose it to high temperatures or direct sunlight.
•In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.
•Do not immerse the appliance in water (with the excep on of cleaners) or mud.
•Do not discharge R410A or R407C fl uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered
by the Kyoto Protocol, with a Global Warming Poten al (GWP) = 1975 for R410A or 1653 for R407C - (Direc ve EC
842/2006).
•According to French decree No. 2007-737, if the appliance has more than 2 kg of refrigerant gas (refer to manufacturer
specifi ca ons), the cooling circuit must be checked for leakage at least once a year. This opera on must be carried
out by a cer fi ed cooling appliance specialist.
Addi onal recommenda ons in rela on to the Pressure Equipment Direc ve (PED-97/23/EC)
Installa on and maintenance
The unit may not be installed close to combus ble materials, or the air duct inlet of an adjacent building .
With some devices, it is essen al to fi t protec on grids if the unit is installed in an area with uncontrolled access.
During installa on, troubleshoo ng and maintenance, pipes may not be used as steps: the pipe could break under the weight,
spilling refrigerant and possibly causing serious burns.
When servicing the appliance, the composi on and state of heat carrying fl uid must be checked, as well as the absence of any
refrigerant.
During the annual unit sealing test in accordance with applicable legisla on, the high and low pressure switches must be
checked to ensure that they are securely fastened to the coolant circuit and that they cut-off the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around cooling components.
Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi ng the temperature and
pressure sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high
pressures with the consequent risk of severe scalding.
Troubleshoo ng
All soldering work must be carried out by a someone qualifi ed to do so.
Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.
Leak detec on, pressure test:
- never use oxygen or dry air, risk of fi re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informa on plate,
- the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A), 20 bar and 15 bar (for
R407C) in the case the device is equipped with the op onal pressure gauge.
The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1’’5/8. A cer fi cate as
indicated in §2.1 in compliance with standard NF EN 10204 will be requested from the supplier and fi led in the facility’s
technical documenta on.
Technical data rela ve to the safety requirements of the various applicable direc ves must be indicated on the informa on
plate. All this informa on must be recorded in the unit’s installa on manual, which must be kept in the technical fi le of the
unit: model, code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturer’s address,
refrigerant and weight, electrical parameters, thermo-dynamic and acous c performances
Recycling
This symbol means that your appliance must not be thrown into a normal bin. It will be selec vely collected for the
purpose of reuse, recycling or transforma on. Any substances it may contain which are poten ally dangerous to the
environment shall be eliminated or neutralised.
Request informa on on recycling procedures from your retailer.

2H0548600.B - EN - 2016-05
CONTENTS
❶ Installa on 3
1.1 I Selec ng the loca on 3
1.2 I Hydraulic connec ons 4
1.3 I Electricity supply connec ons 5
1.4 I Op on connec ons 6
❷ Use 8
2.1 I Opera ng principle 8
2.2 I User interface presenta on 8
2.3 I Opera ng 9
2.4 I User func ons 9
2.5 I Presenta on of the menu 10
❸ Maintenance 11
3.1 I Wintering 11
3.2 I Maintenance 11
❹ Troubleshoo ng 12
4.1 I Device behaviour 12
4.2 I Error code display 13
4.3 I Addi onal menus 14
4.4 I Wiring diagrams 15
❺ Specifi ca ons 18
5.1 I Descrip on 18
5.2 I Technical specifi ca ons 19
5.3 I Dimensions and marking 19
• Before you do anything with the device, it is vital that you read this installa on and user
manual, as well as the "warnings and warranty" booklet delivered with the device. Failure to
do so may result in material damage or serious or fatal injury and will devalidate the warranty.
• Keep and pass on these documents for later consulta on during the device's life me.
• It is prohibited to distribute or modify this document in any way without authorisa on from
Zodiac®.
• Zodiac® is constantly developing its products to improve their quality; therefore, the
informa on contained in this document may be modifi ed without no ce.
Tip: to make it easier to contact your reseller
• Write down your reseller's contact details to help you fi nd them more easily and fi ll in the "product"
informa on on the back of the manual; your reseller will ask you for this informa on.
EN

H0548600.B - EN - 2016-053
❶ Installa on
1.1 I Selec ng the loca on
• The device must be installed at a minimum distance from the pool's surrounding edge.
This distance is determined by the electrical standards which apply in the installa on country.
• Do not li the appliance using the casing, handle it from the base.
• For outdoor installa on, provide free space around it (see § “1.2 I Hydraulic connec ons”).
• For indoor installa on, the device must be equipped with the plant room kit.
• Install the 5 an -vibra on studs under the base and place the device on a stable, solid and level surface.
• This surface must be able to bear the weight of the device (in par cular in the case of installa on on a roof, a balcony
or any other support).
• The device may be secured to the ground using the holes in the base of the device or with rails (not supplied). A
drilling scale is available on the back of the packaging carton.
: front
: rear
: connectors
: An -vibra on studs
: A achment holes
Bo om view of the appliance base for a achment to the ground and loca on of the
an -vibra on studs
The device must not be installed:
• In a loca on subject to high winds,
• With the blowing towards a permanent or temporary obstacle (window, wall, hedge, awning, etc.) less than 4 metres
away,
• Within range of water or mud jets, sprays or run-off (take the eff ect of the wind into account),
• Near a heat source or fl ammable gas,
• Near high frequency equipment,
• In a loca on where it would be subject to snow build-up,
• In a loca on where it might be fl ooded by the condensa on produced by the device when opera ng.
Tip: reduce any noise annoyance from your heat pump
• Do not install it under or towards a window.
• Do not lt it towards your neighbours.
• Install it in a clear space (the sound waves are refl ected on surfaces).
• Install an acous c screen around the heat pump, respec ng the distances.
• Install the an -vibra on studs under the heat pump and replace them regularly.
• Install 50cm of fl exible PVC pipe at the heat pump water input and output (stops vibra ons).

4H0548600.B - EN - 2016-05
1.2 I Hydraulic connec ons
• The device will be connected with a Ø50 PVC pipe, using the half union connectors supplied (see § “5.1 I Descrip on”),
to the pool's fi ltra on circuit, a er the fi lter and before the water treatment.
• Respect the direc on of hydraulic connec on.
• A by-pass must be installed to make it easier to work on the device.
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve
(op onal)
: water exit adjustment valve
(op onal)
: water treatment
* minimum distance
• To evacuate the condensa on, fi t a Ø18 pipe on the grooved elbow mounted under the device base.
• The elbow may be oriented to the rear or the side of the device.
Condensa on drainage orienta on
Tip: condensa on drainage
Cau on, several litres of water must be drained from your device each day. We strongly recommend
connec ng the drainage to the sewers
EN
This manual suits for next models
23
Table of contents
Other Zodiac Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual