Zodiac Z300 Series User manual

H0439100.A - 2013/10
Instruc ons for installa on and use
English
More languages on:
www.zodiac-poolcare.com

H0439100.A1.EN–2013/10
1
Readthismanualcarefullybeforeinstalling,maintaining,orrepairingthisdevice!
Thesymbolindicatesimportantinformationthatmustbetakenintoaccountinordertoavoid
riskofpersonalinjuryand/ordamagetotheappliance.
Thesymbolindicatesusefulinformation.
Warnings
Ourproductsmaybesubjecttochangewithoutnoticeaspartofourcontinuousimprovement
policy.
Exclusiveuse:poolwaterheating(mustnotbeusedforanyotherpurpose).
Thedevicemustbeinstalledbyaqualifiedtechnicianaccordingtothemanufacturer’sinstructions
andincompliancewithlocalregulations.Theinstallerisresponsibleforthecorrectinstallationof
thedeviceandforensuringcompliancewithlocalregulations.Themanufacturershallnotbeheld
liableforanypotentialissuesthatmayoccurasaresultoffailuretocomplywithlocalstandards
pertainingtoinstallation.
Thisappliancemustbehandledbycompetentandqualifiedpersonnel(physicallyandmentally)who
arefamiliarwiththeoperatinginstructions(byreadingtheuserguide).Individualswhodonot
satisfytheserequirementsmustnothandlethedevicesoastoavoidexposuretopotentially
dangerousparts.
Inthecaseofdevicemalfunction:donotattempttorepairthedeviceyourself,callyourinstaller.
Beforecarryingoutanyoperationonthedevice,ensurethatthepowersupplyisoff,thatthedevice
isdecommissioned,andthatthe"heatingpriority"functionisde‐activated.
Beforereconnectinganycomponent,checkthatthevoltageindicatedonthedevicecorrespondsto
themainsvoltage.
Ifanysafetydeviceisremovedorshunted,thewarrantywillautomaticallybevoid.Thiswillalso
applyifpartsarereplacedwithpartsacquiredelsewherethaninourstores.
DonotventR410Afluidintotheatmosphere:R410Aisafluorinatedgreenhousegasthatiscovered
bytheKyotoProtocol,withaGlobalWarmingPotential(GWP)=1975‐(seeregulationon
fluorinatedgreenhousegases,EuropeanCommunityDirectiveEC842/2006).
Incorrectinstallationmaycauseseriousdamageand/orpersonalinjuries(potentiallydeath).
Keepthedeviceoutofthereachofchildren.
Thisheatpumpiscompatiblewithalltypesofwatertreatmentsystems.

H0439100.A1.EN–2013/10
2
Summary
1.Informationbeforeinstallation................................................................................2
1.1Generaltermsofdelivery,storageandtransport.......................................................................................2
1.2Content........................................................................................................................................................2
1.3Operatingconditions...................................................................................................................................3
1.4Technicalspecifications...............................................................................................................................3
2.Installation...............................................................................................................3
2.1Accesstothetechnicalcompartment.........................................................................................................3
2.2Selectinganinstallationsite........................................................................................................................3
2.3Installingthedevice.....................................................................................................................................4
2.4Hydraulicconnections..................................................................................................................................4
2.5Electricalconnections..................................................................................................................................5
3.Use..........................................................................................................................7
3.1Presentationoftheregulation.....................................................................................................................7
3.2Startingthedevice.......................................................................................................................................8
3.3Checkstoperformafterstart‐up.................................................................................................................8
3.4Winterstorage.............................................................................................................................................9
4.Maintenance............................................................................................................9
4.1Maintenanceinstructions............................................................................................................................9
4.2Additionalrecommendations......................................................................................................................9
4.3Availableaccessories.................................................................................................................................10
4.4Recycling....................................................................................................................................................10
5.Troubleshooting....................................................................................................10
5.1Displayoftheregulator.............................................................................................................................10
5.2Sovlingmalfunctions..................................................................................................................................12
5.3FAQ.............................................................................................................................................................12
6.Productregistration...............................................................................................13
Informationincludedattheendofthemanual:
- wiringdiagrams
- dimensions
- description
- compliancecertificate
1.Informationbeforeinstallation
1.1Generaltermsofdelivery,storageandtransport
Anyequipment,evenshippingandpackingfree,travelsattheconsignee'srisk.Ifanydamagecausedduring
transportisidentified,theconsigneeshouldmakeanyreservationsinwritingonthecarrier'sbilloflading
(confirmationtobesenttothecarrierwithin48hoursbyregisteredmailwithacknowledgementofreceipt).
Thedevicemustbetransportedandstoreduprightonitspalletinitsoriginalpackaging.
Ifthedevicehasbeenturnedonitsside,thisshouldbementionedinthereservationsmadeinwritingtothe
carrier.
1.2Content
Ø50
X1X2X2X1
inabaginthetechnicalcompartment,see§2.1

H0439100.A1.EN–2013/10
3
1.3Operatingconditions
Operatingrange:
airtemperatureofbetween5°Cand38°Cforstandardmodels,
airtemperatureofbetween‐8°Cand38°CforDmodels,
watertemperatureofbetween10°Cand32°C,
Maximumtemperatureof32°Ctoprotectthepoolliner.
TheDversionalsofeaturesade‐icingfunctionbyusingforcedventilationorreversedcycle.
1.4Technicalspecifications
Z300VoltagePowerinput* Poweroutput*Nominalcurrentinput*COP*
kWkWA
M4230V‐50Hz1.77.67.94.5
M5230V‐50Hz2.210.410.34.7
T5400V‐50Hz2.210.54.254.8
M7230V‐50Hz2.8813.9134.8
MD5230V‐50Hz2.210.7104.9
TD5400V‐50Hz2.210.54.44.8
MD8230V‐50Hz3.615.7164.5
TD8400V‐50Hz3.615.77.44.5
*withambientairat+15°C,poolwaterat26°C,andrelativehumidityof70%(accordingtoFrenchstandardNF‐
414)
protectionclass:IP24
refrigerantgas:R410A
refrigerantcharge:seeproductinformationplate
class:I,
degreeofpollution:2,
overvoltagecategory:II
2.Installation
Donottakegripontheoutercasingtopickupthedevice,holdthebase.
2.1Accesstothetechnicalcompartment
2.2Selectinganinstallationsite
Thedevicemustbeinstalledoutdoorsandtheremustbeadequateopenspacesurroundingit(see
§2.4).
theheatpumpmustbeinstalledatacertaindistancefromthepoolsoastoavoidexposuretowatersplashes.
Theappropriatedistanceshouldbedefinedaccordingtothenationalelectricalstandardsthatapplyinthe
countryofinstallation(forFrance:3.5meters).
theheatpumpmustnotbeinstalled:
- nearasourceofheatorinflammablegas,
- neararoad/passagewherethereisariskofwaterandmudsplashes,
- facingastrongwind,
- withtheventfacingtowardapermanentortemporaryobstacle(window,wall,hedge,etc…),itmustbeat
least4metersfromanypotentialobstacle.

H0439100.A1.EN–2013/10
4
2.3Installingthedevice
placeonastable,solid(concreteslabtype),levelandplanesurface,
ensurethatitwillnotbefloodedbycondensationwaterproducedbythedeviceduringoperation(see§2.4)
Theanti‐vibrationblocsarefittedunderthebaseoftheheatpump.
Theheatpumpcanbefixedtothegroundusingthebracketsatthebaseoftheunit(attachmentsnot
included).Adiagramfordrillingisfeaturedonthebackofthepackingbox.
2.4Hydraulicconnections
Checkthedirectionofthepipeworkconnection(see§“Dimensions”intheappendix).
TheconnectionincludeaØ50PVCrigidpipe,fromaby‐pass,ontheswimmingpoolfiltrationcircuit,afterthe
filterandbeforeanywatertreatmentunit.
checkthetighteningofthehydraulicconnections,andcheckforleaks,
Z300
HydrauliccircuitpressureConnections
=inlet
=outlet
Meanwater
flowrate
Headloss
test
test service
barbarm³/hmCE
M4
31.5Ø50
41.4
M5‐T5‐
MD5‐TD551.5
M761.5
MD8‐TD86.51.1
V1‐V2‐V3:by‐passvalves
V5‐V4:settingvalves(optional)
*minimumdistance
by‐pass
filter
watertreatmentunit
electricalprotectionboxes
Fixingholes
Other manuals for Z300 Series
3
Table of contents
Other Zodiac Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual