MODEL PA2500 MACHINE MAINTENANCE (EVERY 6-12 MONTHS)
STEP 1: OPEN THE TOP OF THE MACHINE TO CLEAN MACHINE Remove the 6 screws (2 screws from each side and 2 screws on top) and lift the cover off the machine.
STEP 2: LIFT THE DUST PROTECTOR STRAIGHT UP AND REMOVE AND
TAKE THE CERAMIC PLATES OUT
Before you take the ceramic plates out, lift up and remove the 4 plastic dust protectors that are located at the back end
of the plates (closer to the fans) and remove the 4 ceramic plates from the machine.
Note: Set dust protectors aside and after you clean the plates and inside the machine, reinstall them by sliding them
back onto the slot that they were removed from on the back of the plate holder.
STEP 3: CLEANING THE MACHINES AND CHANGING THE PLATES (EVERY 6-12 MONTHS)
The ceramic plates should be replaced every 6-12 months or as necessary. Cleaning the machine is very important!
After continuous use and as a course of normal wear, the ceramic plates will develop microscopic holes, compromising
the integrity of the machine due to the buildup of contaminants inside the machine, especially on the brackets and
plates. For your convenience, the parts department will periodically remind you when it is time to reorder parts.
In order for the machines to create a true “corona discharge”, which creates the output of ozone, the following parts must be free from debris and corrosion and
should be cleaned or changed out each time during your scheduled maintenance of the machines which is usually every 6-12 months depending on use and climate:
CHANGE OUT THE WHITE CERAMIC PLATES AND THROW AWAY OLD PLATES:
The ceramic plates must be replaced. Throw the plates that are in the machine away. Do not keep them.
They will get mixed up with the new plates. Similar to batteries, you do not want to replace only a few plates
and keep a few of the old plates inside the machine.
CLEAN THE TITANIUM PLATES: The titanium plates must be cleaned every 6-12 months (the 8 titanium
plates that are on each side of the brackets that hold in the ceramic plates). They look like stainless steel
pieces of metal on each side of the bracket.
CLEAN INSIDE THE TITANIUM PLATES THAT HOLD THE CERAMIC PLATES:
Important! Cleaning in between the plastic titanium plate brackets that hold the ceramic requires
complete attention. Be careful not to spread the titanium bracket holders not too far because they will snap
due to the fact that they have glass/plastic alloy).
IMPORTANT!
Before installing ceramic plates, clean between the titanium plates using a Zontec™ alcohol wipe. Pull the alcohol
wipe tight and start off by placing it between the titanium brackets in one corner, making it easier to slide the wipe
between the titanium brackets Clean gently but thoroughly between the brackets using a side to side motion (similar
to shining your shoes). Do not reuse plates in the future because you will compromise the system.
STEP 4: CHANGE AIR FILTERS: The air filters are used to filter debris away from the ceramic plates and keep the
machine clean. The filters should be changed once every 6-12 months. Simply lift out the filter holders and replace the
filters. The PA2500 model has 2 filters. They are located on the rear panel, one on each side of the machine.
STEP 5: RE-INSTALL THE CERAMIC PLATES / TESTING THE MACHINE
After cleaning machine thoroughly, reinstall the plates and put back the dust protectors. Replace the screws in the
machine and test the machine. Carefully pry open the titanium bracket and slide the ceramic plates back in between the titanium plate brackets (they will fit snugly)
and make sure that they “bottom out”. Once you have all plates installed, replace the dust protectors to their positions in the brackets.
Testing The Machine: Plug the machine in and press the timer manual button to “ON” and make sure that the green lights in front
of the machine come on. If so, immediately press the manual button back to “AUTO”. Your timer should indicate “AUTO” at
all times.
If the machine does not have either one of the two green lights on, refer to the troubleshooting section of this manual. (Note: The
green lights are indication lights. “Green” means that the machine is functioning properly. “Unlit” means the machine is not
functioning properly. There are 2 lights, and each one is an indicator. One for the left side and the
other is an indicator for the right side of the machine.
NOTE: Periodically inspect the machine to make sure that the green lights are working on the machine. The green light only comes on when the machine is running.
If a machine does not have the green light on, than that means that a fuse has blown on the machine which is a good indication the ceramic plates need to be
changed or the machine needs to be cleaned. If it is close to the 6-12 month period for maintenance, than you need to schedule your maintenance of all machines
and order your maintenance kits. Note: The machine will not blow out ozone when the plates are worn out. It will only blow out air.
STEP 6: CHECK THE CORONA DISCHARGE
Check for the “corona discharge” in the front of the machine. When the 2 green lights on the front (face) of the PA2500 are
lit, this indicates that the electrical output is constant. To verify that you are getting the maximum output of ozone,
periodically examine the front of the machine. You should see a vertical “black light” line that is straight with no spotting,
sparking, waviness or arcing. If this is not the case, then this indicates that the titanium plates need to be cleaned again. (If
you cannot see the black light, plug the machine in a darker area of the room or a separate office area) If you see the straight
line, then your machine is running at optimum performance.
WARNING: MAKE SURE MACHINES ARE UNPLUGGED WHEN CLEANING THEM! RUN MACHINES IN
UNOCCUPIED SPACE ONLY. Prolonged exposure to ozone could be harmful to your health.
WIPE BETWEEN TITANIUM
PLATES
CORONA
DISCHARGE
(PURPLE/BLACK
LIGHTS)