ZyAura ZG1163R User manual

ZG1163R CO2and Temperature Monitor Operating Instructions
Product Overview
Thank you for selecting ZG1163R desktop CO2monitor, ZG1163R CO2monitor is smart, compact and easy-to-use. In addition to measuring the CO2
concentration, ZG1163R can also measure the ambient temperature and the relative humidity. This product is developed to detect the presence of CO2in
ambient air and help people to take care of Indoor Air Quality. ZG1163R can be widely used in the office building, school, exhibition, shopping mall, meeting
room, fitness center, restaurant and other pubic place where personal comfort, healthy is important.
Features:
□
VThe built-in Data logger can store 48 sets of CO2and temperature and RH in the past 24 hours; one log per 30 minutes.
□
VMax/Min mode can record the maximum and minimum concentration of CO2since the device has been last turned on.
□
VTheAlarm mode theAlarm Level can be adjustable by user.
□
VThe RCFS Mode can recover the original factory settings after the CO2device has been recalibrated, altered, or damaged.
Mode Functions
There are several Modes which can be adjusted by user.These modes are Mute Mode, ALTI Mode,ALARM 1 Mode,ALARM 2 Mode, OUTSIDE Mode, CALI Mode,
LOG Mode, MaxMin Mode and RcFS Mode in sequence.
MUTE The beep alarm can be setting
on/off under Mute Mode
ALTI
Compensate the pressure
changes with appropriate
altitude of location when
measure
ALARM 1 The first alarm level can be
adjusted by user
ALARM 2 The second alarm level can be
adjusted by user
OUTSIDE Modify the outside CO2
concentration for calculating
the ventilation rate
CALI Calibrate the sensor while the
reading deviates from the
actual CO2concentration
LOG Show the past CO2,
Temperature and RH records in
the past 24 hours
MaxMin Show the Max and Min CO2
reading before being cleared or
after Power On
RcFS Recover the factory setting to
cancel customize setting
Safety Instructions
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning and entire User Manual
before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, do not subject the product to impact or shock. Otherwise, this may cause the accuracy drift.
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in damage.
3. Do not keep the product under the hot and moisture environment. Keep the product away form the heat source or near water.
4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death to the user.
Caring for product
To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product needs servicing.
1.Enter Button 4. Mode Button 7. Yellow LED Display (800-1200ppm) 10. Power inlet
2. Down Button 5. LCD display 8. Red LED Display (>1200ppm) 11. RJ45 socket (only for factory use)
3. Up Button 6.Green LED Display (<800ppm) 9.Gas Entry Hole 12. Ventilation Slots
(Display features and modes)

3.Air diffusion---The ventilation slots on the housing are designed for CO2 diffusion, so these ventilation slots should not be blocked.
Customize Settings
When the power has been connected, The ZG1163R CO2monitor will begin to work. In order to meet your personal requirements, it is advisable to set up the customizing
parameters.
WarmUp: It lasts approximately 1min before WARM UP disappears; all MODE functions will not response during warm up.
Temperature (ºC/ºF) RH and Ventilation Rate:
1. Press up/down to select the temperature, RH and ventilation rate modes.
2. When pressing up button, the LCD display sequence is Temp ºC -> Temp ºF -> Vent Rate lps -> Vent Rate cfm/p
When pressing down button, The LCD display sequence is reverse.
*Note: Temp ºC refers toTemperature in Celsius;Temp ºF refers to Temperature in Fahrenheit. Vent Rate lps refers to Liter Per Second Per Person; Vent Rate cfm/p refers to
Cubic Feet Per Minute Per Person
Using the MUTE function:
Note: The factory setting with alarm is buzzer off, user can set the alarm on/off under MUTE function.
Using theALTI mode:
Setting the ALARM 1 level:
1. Press Mode, theALARM 1 icon flashes.
2. Press Enter. Using the Up/Down to set the parameter, the defaultALARM 1 is 800 ppm.
3. Press Enter again to save the data.
*Note:1)When CO2Alarm level is ≧1,000 ppm, the interval is ±100ppm, when the CO2Alarm level is <1,000 ppm, the interval is ±50 ppm
2)After setting with new alarm level parameter, the green LED will light when CO2concentration below the alarm 1 level.
Setting theALARM 2 level:
1. Press Mode, theALARM 2 icon flashes.
2. Press Enter. Using the Up/Down to set the parameter, the defaultALARM 2 is 1200 ppm.
3. Press Enter again to save the data.
1. Press Mode, the speaker icon flashes simultaneously.
2. Press Enter, use up/down to select the on/off.
3. Press Enter again to save the data.
1. Press Mode,the ALTI icon flashes.
2. Press Enter,ALTI shows on the display, press the mode button to alter between the m( meter) and ft(feet).
3.Adjust altitude (step=100m/500ft) by up/down button.
4. Press Enter again to save the data.

*Note:1)When CO2Alarm level is ≧1,000 ppm, the interval is ±100ppm, when the CO2Alarm level is <1,000 ppm, the interval is ±50 ppm.
2)After setting with new alarm level parameter, the green LED will light when CO2concentration below the alarm1 level. The red LED will light when CO2concentration
exceeds the alarm 2 level, the yellow LED will light when CO2concentration is between the alarm1 level and the alarm 2 level.
Using the OUTSIDE mode:
1. Press Mode, the OUTSIDE icon flashes.
2. Press Enter, shows OUTSIDE, CO2and ppm flashes. Press the Up/Down to adjust the data.
3. Press Enter to save the setting. After the modification, the VENT Rate will change.
*Note: Ventilation rate represents how much air is introduced into the indoor space from outside. Low numbers indicate low ventilation rates and potentially poor air quality.
High levels indicate excessive ventilation and potential excessive energy usage. To obtain an accurate measurement, reading should be taken 2~3 hours after
occupancy has stabilized in a space or at a peak in daily CO2 concentrations. For indoor air quality control, CO2value is an indicatorof ventilation rate. 400ppm (Parts
Per Million) is the default CO2concentration outside according toASHRAE:American Society of Heating, Refrigeration andAir conditioning Engineers.
Using the CALI (calibration) mode:
1. Press Mode, The CALI icon flashes.
2. Press Enter, the CALI icon on the display. Adjust the CO2reading by Up/Down button.
3. Press Mode for more than 10sec,CALIBRATING flashes. Calibration will be done automatically after about 3 minute and the LCD will display “Pass” or “Fail.” If
it shows “Fail,” please try again.
Using the LOG mode:
1. Press Mode, LOG icon flashes.
2. Press Enter, CO2 reading and Temperature show on the LCD.
3. Press Up/Down to page up/down the reading.
*Note: With the Built-in Datalogger, ZG1163R can providethe past CO2, temperature and RH reading within the past 24 hours.The log interval is 30 minutes per data.
ZG1163R is connected with power and used for the first time. If the working time is more than 30minutes, ZG1163R will have CO2, RH and temperature reading in
datalogger, if the working time is less than 30 minutes, the LCD will display “NULL” while using the LOG function.
Using the MAX MIN mode:
*Note: With the Built-in MAX MIN mode,ZG1163R can provide the Maximum and Minimum CO2readings since the device has last been turned on. If users press up/down to
clear the MAX and MIN CO2reading record, ZG1163R will provide the new MAX and MIN CO2reading from that time.
Using the “RcFS” Mode:
*Note: If the user sets the data or calibrates the ZG1163R incorrectly, use the RcFS (recover the factory Setting) to come back the default factory setting.
1. Press Mode, the MAX MIN icon flashes.
2. Press Enter, the MAX and MIN CO2reading alternatively shows.
3. Press Down and the “CLr” will flash on the LCD. Press Enter to CLEAR the MAX and MIN record.
1. Press Mode, The RcFS icon flashes.
2. Press Enter, the icon “no” shows on the LCD, Press the Up/Down to select the no/yes.
3.After selecting, press Enter to save the setting.

Ref.No.:012013
SPECIFICATIONS
Method - Dual Beam NDIR (Non-Dispersive-Infrared)
Display - LCD
Independent CO2, RH and Temperature readings. Calculates and Displays Ventilation Rates
Sample Method - Diffusion or flow through (50 ~200 ml/min)
CO2, Temperature & RH Specification:
CO2Specification
Measurement Range 0-3,000 ppm display
Display Resolution 1ppm at 0~1,000ppm; 5ppm at 1,001~2,000ppm; 10ppm at 2,001~3,000ppm
Accuracy 0~2,000ppm: ±70 ppm or ±5% of reading, whichever is greater; over 2000ppm: +/-7%
Temperature Dependence Typ. ±0.2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C
Pressure Dependence 0.13% of reading per mm Hg (Corrected via user input for altitude)
Repeatability ±20 ppm @ 400ppm Response Time About 2min for 63% of step change
Warm-Up Time <60 seconds at 22°C Zone LED Display Green:<800ppm; Yellow:800~1200ppm;Red: >1200ppm
Temperature Specification
Temperature Range 0°C to 50°C (32°F to 122°F)display
Display Resolution 0.1°C (0.1°F)
Display Options °C/°F Response Time 20-30 minutes (case must equalize with environment)
Accuracy ±1°C( ±2°F) When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC
RH Specification Operating Conditions
Measurement Range 20%-90% RH Operating Temperature 0°C to 50°C (32°F to 122°F)
Display Resolution 1%RH Humidity Range 0 ~ 95% RH non-condensing
Accuracy: ±5%RH@23°C Storage Conditions
Response time: <5 min for 63% of step change Storage Temperature -20°C to 60°C( -4°F to 140°F)
Power Supply
Power Supply 100 ~ 240 VAC 50 / 60 Hz
6 VDC from externalAC/DC adapter which is included in package (Use specified AC adapter only)
Dimension
Fault Codes & Troubleshooting Guide
This section includes a list of FrequentlyAsked Questions for problems you may encounter with the ZG1163R CO2 Monitor.
Fault Icon Description of the fault Suggested Actions
「 」 The ambient temperature has exceeded the operating
temperature range 0°C to 50°C (32°F to 122°F) This error will clear when the temperature returns to the range between 0°C to
50°C (32°F to 122°F).
「 」
EEPROM System Problem Please reconnect AC adapter to ZG1163R CO2 Monitor.
If the “Err5, Err6” still appears, please contact the Service Department for further
assistance.