manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 2N Telekomunikace
  6. •
  7. Gateway
  8. •
  9. 2N Telekomunikace ATEUS EasyGate 501309E User manual

2N Telekomunikace ATEUS EasyGate 501309E User manual

Other 2N Telekomunikace Gateway manuals

2N Telekomunikace ATEUS EasyGate 501300E User manual

2N Telekomunikace

2N Telekomunikace ATEUS EasyGate 501300E User manual

2N Telekomunikace ATEUS EasyGate User manual

2N Telekomunikace

2N Telekomunikace ATEUS EasyGate User manual

2N Telekomunikace 2N StarGate User manual

2N Telekomunikace

2N Telekomunikace 2N StarGate User manual

Popular Gateway manuals by other brands

LST M500RFE-AS Specification sheet

LST

LST M500RFE-AS Specification sheet

Kinnex Media Gateway quick start guide

Kinnex

Kinnex Media Gateway quick start guide

Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications ZYWALL2 ET 2WE user guide

ZyXEL Communications

ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey CPVA 500 - SIP Technical manual

Telsey

Telsey CPVA 500 - SIP Technical manual

RTA 460A-NNA4 Product user guide

RTA

RTA 460A-NNA4 Product user guide

Shaw Gateway HDPVR user manual

Shaw

Shaw Gateway HDPVR user manual

ABB VSN900 Commissioning manual

ABB

ABB VSN900 Commissioning manual

Commander Pulse owner's manual

Commander

Commander Pulse owner's manual

NETGEAR C6300BD installation guide

NETGEAR

NETGEAR C6300BD installation guide

Amit CDW531AM user guide

Amit

Amit CDW531AM user guide

HMS Netbiter EasyConnect EC150 user manual

HMS

HMS Netbiter EasyConnect EC150 user manual

Huawei EchoLife HG620 user guide

Huawei

Huawei EchoLife HG620 user guide

AT&T U-verse 3801 Replacement self-installation guide

AT&T

AT&T U-verse 3801 Replacement self-installation guide

Logic IO RTCU MX2 turbo Technical manual

Logic IO

Logic IO RTCU MX2 turbo Technical manual

Suttle MediaMAX MXM-521 installation instructions

Suttle

Suttle MediaMAX MXM-521 installation instructions

RTA 460MCBC-N2E Product user guide

RTA

RTA 460MCBC-N2E Product user guide

Rosonix Technology RSG-3000 user manual

Rosonix Technology

Rosonix Technology RSG-3000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

©2005, 2NTELEKOMUNIKACEa.s. –Prague,LH1238 v.1.2
EasyGate 3G QuickStart
ReadtheCD-ROMUserManualcarefullytoget familiarwithall system functions.
Security Precautions
· Do notswitchonEasyGate3Ginthe vicinityofmedical
apparatusestoavoidinterference.The minimumdistance
of the antenna and pacemakers shouldbe0.5m.
· Do not switchon EasyGate3G aboard aplane.
· Do notswitchonEasyGate3G nearpetrolstations,
chemicalfacilities or siteswhereexplosives are used.
· Anymobiletelephone useprohibitionbasedonRFenergy
radiationapplies toEasyGate3G too.
· EasyGate3G maydisturb the function ofTVsets, radio
sets and PCs.
· Warning!EasyGate3G containscomponents thatcan be
swallowedbysmall children(SIMcard, antenna,etc.).
· The voltage valuementionedon theadaptermaynotbe
exceeded.If youconnect EasyGate3G toanother power
supply,makesure thatthe voltage valueliesinthe
acceptablerange.
· When yourEasyGate3G comestothe endofits
operationallife, disposeofitinaccordancewithapplicable
regulations.
AnEasyGate3Gdeliverycontainsthe
following:
EasyGate3G 1pc
Phone holder withbelts 1pc
Supplyadapter 1 pc
Telephone cable 1 pc
PC-connectionserialcable 1pc
SMS sending input
connector 1pc
Dowels 2pcs
Screws 2pcs
UserManualonaCD-ROM
1pc
QuickStartmanual+
mounting pattern 1pc
Sotware on aCD-ROM 1pc
Warranty certificate 1 pc
BasicFunctions
· The primarypurposeof
EasyGate3Gistotransmitvoice
betweenaUMTS/GSMnetwork
andan attachedFXO-interface
terminal.
· You cansend anSMStoapre-
programmed numberusingthe
SMS sendinginput.
ProperLocation
· EasyGate3Gisdesigned forverticalmounting on
suspension holes (usethe mounting pattern).
· InstallEasyGate3G withrespect toagoodGSMsignal
strength.
· PlaceEasyGate3Goutofrangeofsensitivedevicesand
human bodies forelectromagneticinterferencereasons.
· EasyGate3G isdesignedforindoor use.Donotplaceitnear
heatsourcesandon sitesexposedtodirect solarradiation.It
maynotbe exposedtorain,flowingwaterand moisture.In
addition,itmaynotbeexposed toaggressivegas, acid
vapours, solvents, etc.
MotorolaUMTSPhoneConnection
Install the3GUSIMbeforeconnection
toEasyGate3G.You must switchoff
PINprotection.
Connect datacabletobottom
connector and voicecabletoheadset
connector.Fasten the beltson phone
holder around the phone properlyto
avoidaphone damage.TheV-
phonesmustbe open tooperate.
TelephoneLineConnection
EasyGate3Gcan be connected to
anyFXO-interfaceequipment
(standard telephone set,answering
machine,PBXCOline,...).
EasyGate3G isequippedwithidentification ofcalling
party(CLIP)viaFSK and soitisadvantageoustoconnect a
terminalthat is abletodisplaytheCLI.
PowerSupplyConnection
EasyGate3G isfed with10-16VDCvoltage.Where asource
otherthanthe includedsupplyadapter isused,the voltage
range andpolarityshown onthe EasyGate3G supply
connectorhavetobe maintained.
ExternalAntennaconnection
Incaseofbad signalstrengthor radiointerferenceon
telephone line,installrecommendedexternalantenna for used
Motorolaphone.
SIMCardPINprotection
1.Unfortunately,MotorolaUMTSphonesdon’t
supportPINentering viadatainterface.Itis
notpossibletoprotectyour 3GUSIMbyPIN,
pleaseswitchthe PINprotectionoff before
connecting toEasyGate3G.
Outgoing Call
1.Supposethatthe USIMhasbeeninserted,
the PINnotrequired,and EasyGate3G
registered toGSMnetwork–the GSM
Network LEDis permanentlyon.
2.Hookoff the telephone,you canhear the
dialtone and the Line LEDstarts flashing.
3.Dialthe GSMsubscriber number.
EasyGate3Greceivestone dialling (DTMF)
bydefault. Ifyour telephone transmits pulse
dialling only,programEasyGate3Gto
receivepulsedialling.When youmakea
delayinyour dialling longerthan 5s
(programmable), the connection is established.
4.If the called subscriber isavailable,you can
hear the ringing tone.Ifnot, you can hear the
busytone or anyofthe GSMprovider’s
messages.
5.When the called subscriber answersthe call,
acall isestablished.The Line LEDis
permanentlyon during the call.
6.Hang uptoterminatethecall. TheLineLEDgoes
off. If the calledsubscriber isthefirsttohang up,
youcanhear thebusytone andhangup.
IncomingCall
1.Anincoming call issignalled byringing.The
Line LEDflashes duringringing.
2.Hookoff the phone toestablishthecall.The
Line LEDispermanentlyon duringthe call.
3.For callterminationseethe Outgoing Call
section.
IndicationLEDs
Power
supply
· Light is onwhenever
EasyGate3Gison.
GSM
network
· light =registered toGSM
· flashes oncein1s=not
registered,SIMcard inserted
· flashes oncein3s=not
registered,SIMcard not inserted
· flashes 4timesquickly=PIN
protectedUSIM
· flashes 8timesquickly=blocked
USIM,PUKrequired.
Teleph
one line
· no light=standby
· flashes quickly=line off-hookor
ringing
· light =call
ECDeclarationofConformity
Directive: Electromagnetic compatibility (EMC)89/336/EEC
Manufacturer:2NTELEKOMUNIKACEa.s.
Mod anská621,14300 Prague4,Czech Republic
Declaresthattheproduct:ATEUS® -EasyGate 3G
Modelnumbers: 501309E
Designed for: analog FXS anddata interface, standaloneversion
Usescellular engine: external Motorola UMTSphones types:
A835, C975, E1000orV975
Conforms tothefollowingStandards:
Safety: EN60950:2000,
EMC: EN55024:1998: A1:2001,A2:2003,
EN55022:1994,A1:1995,A2:1996, Cor.1:1997,
EN61000-4-2:1995,A1:1998,A2:2001,
EN61000-4-3:1696,A1:1998,A2:2001,
EN61000-4-4:1995,A1:2001,EN61000-4-5:1995,A1: 2001,
EN61000-4-6:1696,A1:2001,EN61000-4-11: 1994, A1:2001
Thetestswereperformed by thefollowingaccreditedtest laboratory
(laboratories):
TechnicalCentreofTelecommunicationsand Post
Testing laboratory No.1063TESTCOM,AccreditedbyCIA
Hvožďanská3,14801Praha4,Czech Republic.
Thefollowingharmonizedtechnicalstandardswereapplied forconformity
assessment:
EMC: ProtocolNo.: 120/04-EN55022,EN55024,EN61000
Thedocumentationand testreports relevantto theswitchingpowersupply
areheldat: SUNNYComputerTechnology Europe,s.r.o., Kotlanova3, Brno,
62800,CzechRepublic.
Dateandplaceofissue: Prague,Czech Republic, 30.6.2005
Manufacturer’s stamp
Ing. Old ichStejskal,executivedirector