1 Safety and Precautions
1. Please read these notes before attempting to operate the 360 Vision Sirius, and keep for future reference.
2. DO NOT disassemble or remove covers. This will break the water seals and invalidate the warranty.
3. All servicing and repairs must be handled by 360 Vision Technology.
4. Installation should be carried out by suitably qualied personnel, in accordance with local codes of practice
and regulations.
5. 360 Vision Technology Limited accept no liability for any damage caused by incorrect or improper installation.
6. Use only 360 Vision Sirius power supplies.
7. Please handle the Sirius with care, as improper handling may cause damage within this unit.
Table of Contents
1 Safety and Precautions .............................................................................................................................. 2
2 Dimensional Drawings................................................................................................................................ 3
3 Connections ............................................................................................................................................... 4
4 Conguration.............................................................................................................................................. 5
5 PSU Enclosure........................................................................................................................................... 5
6 Important - Care of Painted Surfaces......................................................................................................... 6
7 Storage and Handling................................................................................................................................. 6
8 Warranty..................................................................................................................................................... 6

Sirius Installation Manual v2.1 Page 3
© 360 Vision Technology Ltd.
2 Dimensional Drawings
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.500 1 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
130
TILT SWEEP
210
CABLE GLAND
82
173
36.5 100
16 8.4
(x2)
(184)
25.0
36.5
NAME:
M5710-A
SIRIUS LAMP ASSEMBLY
SMALL - STAND ALONE
ISS DATE REFERENCE
A 211016 FIRST ISSUE
211016
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
SCALE 0.5
Sirius LED Array
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.250 2 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
139
266
234
241
70 101
(4 INCH)
9
917
(253)
32
17
36
NAME:
M3509-B
SIRIUS LAMP ASSEMBLY
STAND ALONE
ISS DATE REFERENCE
A 300315
FIRST ISSUE
B 220616
REVISED
060716
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
- -
MATERIAL: FINISH:
SCALE 0.3
SCALE 0.4
SCALE 0.4
Long Range Sirius LED Array

Sirius Installation Manual v2.1 Page 4
© 360 Vision Technology Ltd.
3 Connections
MAINS input
230Vac
N
L
E
MAINS FUSE
SIR-PSU
MAINS FUSE = 1.0AF
OUTPUT FUSE
SIR-PSU
FUSE 1 = 1.25AT
SIR-PSU
180 x 180 x 100mm
Enclosure Dimensions
Sirius LED Array PSU
MAINS FUSE
SIRLR-PSU
MAINS FUSE 3 = 2AF
OUTPUT FUSE
SIRLR-PSU
FUSE 1 = 6.3AT
FUSE 2 = 1AT
FUSE 4 = N/A
MAINS input
100 - 240Vac
Io Vo
Adj Adj
Model Number: SIRLR-PSU
Serial Number: yymmndd-xxxx
Input Voltage:100-240VAC 50/60Hz
Input current 2.1A
Output Voltage: 30V DC
Output Current: 6.2A
BLUE
SIRLR-PSU
BROWN
255 x 180 x 100mm
Enclosure Dimensions
Long Range Sirius Wiring
360
USE
Long Range Sirius LED Array PSU

Sirius Installation Manual v2.1 Page 5
© 360 Vision Technology Ltd.
The power connection is supplied as a standard length of 3m cable
Red/Black - IR & WL version
Blue/Brown - IR only version
• 24Vdc - 36Vdc (Max)
• 24Vac - 28Vac (Max)
The white light connection is supplied as a standard length of 3m cable (orange/white)
• Normally Open Volt Free contact
• Contact ratings - 1A 30Vdc (Resistive) or 0.5A 125Vac
4 Conguration
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
1.000 2 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
NAME:
M5507-A
LABLE DETAIL
SIRIUS STAND-ALONE
ISS DATE REFERENCE
A - FIRST ISSUE
-
DATE :
-
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
SCALE 1.000
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
1.000 2 OF 2
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
NAME:
M5507-A
LABLE DETAIL
SIRIUS STAND-ALONE
ISS DATE REFERENCE
A - FIRST ISSUE
-
DATE :
-
RELEASED:
APPROVED:
ENGINEER:
--
MATERIAL: FINISH:
SCALE 1.000
5 PSU Enclosure
Material PC/ABS
Dimensions (SIR-PSU enclosure) 180 x 180 x 100mm
Dimensions (SIRLR-PSU enclosure) 255 x 180 x 100mm
Light Sensor - Adjust clockwise to increase sensitivity.
Photocell
IR Intensity - Adjust clockwise to increase IR intensity.
WL Intensity - Adjust clockwise to increase WL intensity.
Note: Adjustment pots are tted underneath the M12 screw plugs. Make
sure screw plugs are tted after adjustments, failure to do so will invalidate
warranty.
Light Sensor - Adjust clockwise to increase sensitivity.
Photocell
IR Intensity - Adjust clockwsie to increase IR intensity.
Note: Adjustment pots are tted underneath the M12 screw plugs. Make
sure screw plugs are tted after adjustments, failure to do so will invalidate
warranty.

Sirius Installation Manual v2.1 Page 6
© 360 Vision Technology Ltd.
6 Important - Care of Painted Surfaces
The powder coating applied to the Sirius LED Array external housing is recognised as being in the forefront
for quality and nish. However, in order to preserve the aesthetic nish it is recommended that the coating is
regularly cleaned.
Regular cleaning on a maximum three month interval, using warm and mild detergent must be undertaken.
Abrasive cleaners including strong solvent must NOT be used at any time.
In areas where the coating may come in contact with concentrated atmospheric pollutants [marine, chemical
and especially bird droppings] it would be prudent to clean more frequently e.g. monthly.
Full documentation of the cleaning schedule MUST be maintained to ensure that a warranty claim can be
considered.
If damage occurs to the coating (e.g. the Sirius LED Array is dropped, scrapped etc), repairs MUST be carried
out immediately.
When the Sirius LED Array is installed in areas where there is a high risk of damage from birds or their
droppings, additional precautions and measures should be used to keep the birds away from the Sirius LED
Array e.g. t anti-bird spikes.
7 Storage and Handling
Sirius LED Arrays should be handled with care and must not be dropped. When Sirius LED Arrays are being
stored before installation they should be kept in the transit packaging and located in a dry indoor environment
preferably between 1°C and 35°C which is dry and dust free. Humidity should such that water vapour is non-
condensing. Sirius LED Arrays can be allowed to be outside this range for short periods of time (24 hours
maximum) for transport (e.g. in aircraft or vans) but must never be allowed to be outside the normal operating
temperature range of -40°C to +60°C even during storage. Before installation the Sirius LED Array should be
clean and dry. (If necessary it should be cleaned and dried taking care that the glass is not scratched).
8 Warranty
This information and/or any technical information – whether received verbally or writing – is given in good faith
but without warranty and this also applies where proprietary rights of third parties are involved. The information
provided does not release you from your obligation to check its validity and to test the products suitability for
the intended purpose(s) and use(s). The application, use and installation of the products either in isolation or in
conjunction with other products used, provided and installed by you on the basis of the technical advice issued
are beyond our control and therefore remain entirely your own responsibility.
©2017 ALL DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
This manual suits for next models
1
Table of contents
Popular Light Fixture manuals by other brands

Beamz Pro
Beamz Pro TIGER 18R user manual

EXC
EXC ECOLOR EC-C8240N quick start guide

Philips
Philips 405X specification

Triton Blue
Triton Blue Q-BEAM200 user manual

The Wand Company
The Wand Company Star Trek Original Series Rock Mood Light manual

Christie
Christie High Performance Xenon Lamp CDXL product manual