ACO PRO I/O User manual

INSTALLATION MANUAL FOR PRO I/O, PRO I/O–60
GENERAL INFORMATION
PRO-I/O and PRO-I/O-60 modules are optional extension
modules for PRO system with relay output and switch
output. Both modules have e ual function, difference
between them is only visual.
PRO-I/O module has standard ACO housing, possible to
suface mount (dimensions: 71x70,5x19,4 mm) and it has
Rj45 socket and screw terminals for connecting the wires.
PRO-I/O-60 is e uipped only with screw terminals for
wires connection, the size (cross-sections is 50 mm)
allows putting the module into 60 mm electric back boxes.
PRO-I/O module optionally extends the system with relay
output and normally open (NO) input. The latter can be
used to call certain receivers (from additional door bell
button) or from remote opening activation (typical
activation of e-lock).
NC/NO contact points work either in monostable or
bistable mode and they can be used to control additional
gate, lights or external calling signal can be connected to
it.
In case call incoming from the I/O module the receiver
shows the picture from the camera (if available) and starts
to ring. Calling from the I/O module is shown by pulsating
key icon and lasts for 10 s. and the receivers with handset
ring with different tone. In order to enable the relay in the
I/O module use F2 button (circle icon). Any action at the
receiver during incoming call from the module cancels the
call and enables the desired action. When the call signal
mode is enabled, the I/O module enables the relay while
there is call from the panel and when the module's input
gets the contact, the I/O module will automatically open
the door. When the input has a permanent contact, every
call from the panel will enable the relay for 1 s and will
open the door.The module can work also as a relay and
trigger the e-lock for the time set in the outside unit, it
doesn't concern opening from the INPUT function of the
outside station (this feature is available in the software
version of the module 2.1 and the panel's version from
v.1.1.5)
TECHNICAL PARAMETERS
•Power voltage 15VDC ±5%
•Max. power consumption 35mA
•Power consumption in standby ~0,14W
•Contacts load 5A/250VAC
•Type of external trigger NO switch
•Resistance ≤ 20Ω
•Contacts type NO/NC with common point COM
•Sockets type RJ45 socket / screw terminals ARK
•Work mode monostable / bistable
•Additional calling type Normally open (NO)
62-002 Suchy Las, ul. Diamentowa 7, tel./ fax + 48 61 843 93 71
www.aco.com.pl /en

CONFIGURATION AND INSTALLATION
Programming of the I/O module is done by switches in the module – according to the diagram below:
The first group of switches (1-2) is responsible for selection
of receivers which will ring in case of incoming call from the
outside button (INPUT). The second group (3-4 and 5-6)
allows to set the work mode of additional output
(OUTPUT). Use switches 3-4 to set which receivers will be
able to control the output regarding the calling address
from the panel. The group of receivers that is allowed to
control the output can be limited by appropriate intercom
address. The switch 7 is responsible for choosing the work
mode of the relay between: monostable (switch off) or
bistable (switch on). During the monostable mode F2
buttons enable the relay for 1 s. Enabled relay is confirmed
with signal tone („bip”) in the receiver and by the PK ON led
in the module. In bistable mode F2 button enables the relay
and it is confirmed by with single signal. Switching off is
done by the user with F2 button – confirmation with double
signal. The relay can be operated from the panel (only
models with keypad) if before entering code or swiping
proximity tag „the key” is pressed. The switch 8 enables call
signal mode (call from the panel) and it changes function of
the outside button (INPUT) to activation of the door
opening in the panel.
Call signal activates the relay (INPUT) for 1 s. (switch 7 off)
during call incoming from the panel to the address set with
the switches 3-4 (check the diagram above). If the switch 7
is in position ON, the OUTPUT will be continually enabled
every 6 seconds (for 1 second) until the panel stops ringing
(call cancels for e.g. Activation of door opening). If INPUT
gets permanent contact, every incoming call from the panel
activates OUTPUT for one second and automatically
activates door opening in the panel. Turning on the
switches 8 and 6 triggers the OUTPUT when the doors are
being opened from the outside unit. Opening in the outside
unit can be triggered from an inside unit (the 'key' button),
from the outside unit (pin code, proximity key tag, not the
INPUT of the outside unit) or from the INPUT of PRO-I/O
module. Activity time of the OUTPUT e uals the time of the
set door opening time in the outside unit.
The I/O module can be connected anywhere to the main
line with RJ45 (connections: IN, OUT) and its location does
not have anything to do with the receivers in the system. If
the RJ45 is not used, the signal line (the terminal: line) has
to be lead to the module together with the power supply
(terminals: +DC and -DC POWER)
Example configurations:
More possibili ies of Familio PRO (sys ems wi h more moni ors, ypical roubleshoo ing and examaple diagrams)
can be found in he manual for Familio PRO sys em available a www.aco.com.pl/en
PRINCIPLES OF STORING USED-UP ELECTRIC EQUIPMENT Used-up electric e uipment may not be stored together with other waste products.
They should be stored in special places assigned for this purpose. When disposing of used-up e uipment, please address appropriate institutions or
companies that provide waste recycling services. - Directive 2002/96/ECC/ of 27.01.2003
U0106enVC.1709
This manual suits for next models
1
Other ACO Control Unit manuals
Popular Control Unit manuals by other brands

Siemens
Siemens SENTRON product manual

EnOcean
EnOcean TCM 515 user manual

Tuxhorn
Tuxhorn tubra-eTherm manual

Chicco
Chicco Clip-On Electronic Module owner's manual

elsner elektronik
elsner elektronik RF-MSG-DST Technical specifications and installation instructions

Pentair
Pentair Aurora CBV-S Installation and operation manual