INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER
1.800.591.9360
TECHNICAL ASSISTANCE FAX: 1.626.855.4894
ACORN SAFETY
P.O. BOX 3527
CITY OF INDUSTRY, CA 91744-0527
UNITED STATES OF AMERICA
BARRIER FREE PEDESTAL MOUNTED EYE/FACE WASHES
Models: S0310-BF, S0320-BF, S0330-BF & S0340-BF,
S0330-BF-AS, S0340-BF-AS
Manual #7109-105-001
Revised: 05/06/13
NOTES TO THE INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical, ANSI Z358.1 and
other applicable codes.
LIMITED WARRANTY
UNITED STATES AND CANADA
Acorn Safety warrants that its products are free from defects in material or workmanship under normal use and
service for a period of one year from date of shipment or 18 months after the date of shipment from factory ,
whichever comes first. Acorn's™ liability under this warranty shall be discharged solely by replacement of repair of
defective material, provided Acorn™ is notified in writing within one year from date of shipment, F.O.B. Industry,
California.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn™ under this warranty.
Acorn™ shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects
in materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties
expressed or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance
with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be
protected on job sites during construction and must be properly maintained after the water has been introduced into
the safety product or Acorn's™ warranty is void.
Acorn Safety a division of Acorn Engineering ™Company

Installation & Operation Manual
PRELIMINARY STEPS
1. Read the installation instructions prior to beginning the installation.
2. Separate parts from packaging and verify all necessary parts are accounted for and undamaged. Obtain missing or
damaged parts from Acorn Safety prior to beginning installation.
3. Flush water supply lines prior to installation. This will remove unwanted debris from the lines and prevent unwanted
blockages in the safety equipment.
4. In order to comply with ANSI Z358.1, the safety equipment must be inspected periodically. An inspection tag is provided for
documentation purposes.
5. All employees at risk of injury/contamination should be informed and trained in the use of this and any other safety
equipment. The signage provided should be highly visible, posted in a well lit area within the area served by the safety
station.
ROUGH-IN
Manual #7109-105-001
Revised: 05/06/13
Acorn Safety a division of Acorn Engineering ™Company
Page 2 of 5
Ø91
8" [231]
DC
BASE FLANGE
MOUNTING
DETAIL
STAINLESS STEEL
BASE FLANGE
DETAIL
Ø31
2" [89] Ø45
8" [117]
Ø71
2" [190]
201
8"
[511]
*33" - 45"
[838 - 1143]
r6" [304] MIN
FROM WALL OR
OBSTRUCTION
B
A
E
A
B
307
8"
[785]
351
4"
[896]
8"
[203]
1
2" NPT VALVE INLET CONNECTION
11
4" NPT DRAIN CONNECTION
Ø
Ø 5
8" (4) MOUNTING HOLES
EYEWASH STRAINER ASSEMBLY
A
B
C
D
E
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM].
2. REFER TO ADA FOR CLEAR FLOOR/GROUND SPACE AND APPROACH REQUIREMENTS.
*3. ANSI Z358.1 REQUIRES NOZZLES TO BE MOUNTED BETWEEN 33" - 45" [838 - 1143] ABOVE
THE FINISH FLOOR.
4. ANSI Z358.1 REQUIRES A MINIMUM DISTANCE OF 6" [152] FROM WALL OR OBSTRUCTION.
3
8" (4) MOUNTING HOLES
5 5
8" [144]
PLASTIC BOWL
113
4" [298]
S/S BOWL
61
4"
[158]

Installation & Operation Manual
Manual #7109-105-001
INSTALLATION INSTRUCTIONS:
Supplies required: ( Not provided by Acorn)
1. Wall Fasteners for signage mounting.
2. Pipe sealant or Teflon tape for sealing water connects.
IMPORTANT: FLUSH WATER SUPPLY LINES PRIOR TO
CONNECTION TO SAFETY EQUIPMENT.
NOTES:
lUse hand tools and wrenches in a manner which will
prevent marring finished surfaces. Strap wrenches or
tools with plastic jaw linings are highly recommended.
lRefer to Rough-In for location of supply and drain lines.
lFragments of Teflon tape or pipe sealant residue can
interfere with the proper operation of this unit. Ensure
pipe sealant methods do not cause contamination in the
system.
STEP ONE: PEDESTAL
1. Position center of pedestal flange “A” a minimum of 0’-9”
from left and rear wall. Position from center of flange “A”
a minimum of 0’-11” from right wall side wall.
2. While holding the flange in position, mark floor flange
mounting hole positions.
3. Remove the flange and install appropriate floor anchors
to receive mounting bolts (supplied by others).
4. Re-position the flange and install mounting bolts and
washers.
STEP TWO: UPPER VERTICAL ASSEMBLY
1. Assemble components “B, C, D, and A” in sequential
order using proper plumbing techniques to seal all made
up threads. Ensure that fittings are aligned and
perpendicular as shown.
STEP THREE: SUPPLY AND DRAIN CONNECTION
Note: Refer to Rough-In for supply line locations
1. Rough-In for pipe fittings to make connection to 1 1/4”
NPT drain connection “E” and 1/2” NPT valve inlet
connection “F”.
STEP FOUR: TEST
1. Verify 1/2” supply valve inlet for the eye/face wash is
turned OFF.
2. Turn on potable water supply.
3. Inspect system for leaks.
4. Verify eye/face wash flows properly.
STEP FIVE: SIGNAGE
1. Position sign “G” with clear visibility, in close proximity to
safety equipment and mark mounting hole locations.
2. Select appropriate 1/4” anchors, screws and washers
(supplied by others) to install signage.
3. Attach inspection “H” tag, supplied, with plastic zip tie.
AND HARDWARE TYP.
A
D
F
BC
E
MOUNTING SCREWS AND
HARDWARE TYPICAL 4X
(PROVIDED BY OTHERS)
WASTE LINE CONNECTION
FITTINGS ( PROVIDED BY
INSTALLER)
MOUNTING SCREWS
2X (PROVIDED BY
OTHERS)
H
G
Revised: 05/06/13
Acorn Safety a division of Acorn Engineering ™Company
Page 3 of 5

Page 4 of 5 Revised: 05/06/13
Installation & Operation Manual
OPERATION INSTRUCTIONS:
become familiar with the location and operation of the
nearest emergency plumbing fixture. Emergency
plumbing fixtures stations are simple to use and require
hands free operation once the station is activated.
Regular instruction regarding proper care and use will
increase confidence that the units are accessible and
function properly.
The route and area surrounding the Eye Wash should
be clear and unobstructed; the sooner eyes are flushed,
the less likelihood of damage. Eye Wash stations should
be located in close proximity to the hazard and take no
more than 10 seconds to reach. In the case of sever eye
contamination the victim may require assistance to the
Eye Wash station and help flushing their eyes.
Safety plumbing fixture equipment should be operated
weekly for a period long enough to verify operation,
clear the supply line of any sediment build-up and
minimize microbial contamination due to sitting water.
1. To start the Eye Wash, swing spray nozzle assembly
over the basin and push the paddle forward to the
horizontal or fully “ON” position. Flushing should start,
popping the spray nozzle caps open.
2. Lower both eyes into flow. Both eyes should be
flushed to prevent contamination from one eye from
being delivered to unaffected eye. Personnel who
wear contact lenses should remove them immediately
prior to or during the flush to prevent the
contamination from remaining against the cornea
possibly causing unnecessary damage or pain.
3. Using thumb and forefingers, fully open eyelids and
flush eyes thoroughly for approximately 15 minutes or
until medical personnel arrive. Be prepared to let the
doctor know what type of contamination has entered
the eye.
4. When finished return the push paddle to the vertical
or fully “OFF” position and return spray nozzle
assembly to standby position. Flushing fluid should
stop. Once flushing fluid has stopped flowing, return
spray nozzle lids to the closed position to protect from
airborne contaminates.
MAINTENANCE GUIDE:
Maintain and inspect in accordance with ANSI Z358.1-
2009
1. Check for obvious signs of wear, broken or defective
equipment. Re-paint if necessary. Replace missing or
defective equipment such as broken push paddles,
missing signs and inspection tags.
2. Remove strainer and washout any debris collected
–replace as required.
3. Operate Eye Wash nozzles using the push paddle to
place ball valve in the fully “ON” position checking for
smooth operation of valve push paddle mechanism at
the same time ensuring that the Eye Wash spray
nozzle caps pop off immediately when actuated. If the
ball valve does not operate smoothly check the
actuating assembly for binding or missing parts. If the
Employees who work with hazardous materials should
Eye Wash spray nozzle caps do not pop off immediately
when actuated check for correct supply inlet
pressure.
4. While in operation, inspect spray nozzles for clogs or
debris correct or replace as required.
5. Return push paddle to vertical or fully “OFF” position
and swing back to stand by position. To prevent Eye
Wash spray nozzles from becoming contaminated,
always close nozzle lids after each use.
Manual #7109-105-001
Acorn Safety a division of Acorn Engineering ™Company

Installation & Operation Manual
Manual #7109-105-001
PARTS LIST
ITEM # PART
NUMBER DESCRIPTION
7101-100-001 EYEWASH, SPRAYHEAD
7101-104-001 FACEWASH, SPRAYHEAD
7101-057-001 EYEWASH W/ S/S LID
7101-058-001 FACEWASH W S/S LID
7101-060-001 YOKE STEM ASSEMBLY
7102-635-001 YOKE STEM ASSEMBLY, S/S
3 7101-108-000 BOWL STRAINER
7101-005-199 PLASTIC BOWL
7101-019-000 S/S BOWL
7101-048-000 PLASTIC BOWL GASKET
7101-046-000 S/S BOWL GASKET
7101-032-022 DRAIN ARM ASSY YELLOW
7101-600-002 DRAIN ARM ASSY, S/S
7101-049-000 SUPPLY TUBE, CHROME
7101-045-000 SUPPLY TUBE, S/S
8 7100-401-000 INSPECTION TAG
7100-140-001 WATER SUPPLY STRAINER
7101-075-001 WATER SUPPLY STRAINER, S/S
7101-205-001 CHROMED BALL VALVE PADDLE- ASSY
7101-210-001 S/S BALL VALVE PADDLE-ASSY
7100-126-022 1 1/4" ELBOW YELLOW
7100-127-000 1 1/4" ELBOW, S/S
7100-165-022 1 1/4" PIPE NIPPLE 17.69" LONG YELLOW
7100-208-000 1 1/4" PIPE NIPPLE 17.50" LONG, S/S
7101-031-022 BASE FLANGE ASSY YELLOW
7101-406-001 BASE FLANGE ASSY, S/S
14 7100-402-000 SAFETY EYEWASH SIGN
7
9
10
11
12
13
1
2
4
5
6
13
12
9
8
7
10
11
6
5
4
3
2
1
14
STAINLESS STEEL
FLANGE
FACEWASH
W/ SS LIDS
Revised: 05/06/13
Page 5 of 5
Acorn Safety a division of Acorn Engineering ™Company
This manual suits for next models
5
Table of contents
Other Acorn Safety Bathroom Fixture manuals
Popular Bathroom Fixture manuals by other brands

Hansa
Hansa SIKOBHE232 Installation and maintenance guide

Hans Grohe
Hans Grohe ShowerTablet Select 700 13183 Series Instructions for use/assembly instructions

Bristan
Bristan Artisan Evo Installation instructions and user guide

Gessi
Gessi RILIEVO 59123 manual

FM Mattsson
FM Mattsson Ebro Flexi installation instructions

Graff
Graff MUS92 installation instructions