Unit 8 IDA Business Park,Whitestown,Tallaght,Dublin 24,Ireland.
Telephone:353 1 462 2585. Telefax:353 1 462 2587. E-mail:sales@actrl.com Web:www.actrl.com
Single Line RS485 Converter
Unit 8, Tallaght Business Centre, Whitestown, Tallaght, Dublin 24, Ireland.
T
elephone:
353
1
462
2585.
T
elefax:
353
1
462
2587.
E-mail:
[email protected] Web:
www
.accesscontrol.ie
Setup for Network Operation
4 3 2 1
BAUDRATE SELECT
9600
19200
Network cable is single shielded twisted
pair: Belden 9501 or similar
ACT 2000 ACT 1000 ACT 1000
NETWORK PRINTER
Timekeeper
Lithium Battery
A
B
0V
TX
RX
Timekeeper
Lithium Battery
A
B
0V
TX
RX
RS485 line may be up to 1km in length
and connect up to 32 controllers
To next Controller
NETWORK
DOORS SERIAL/PRINTER
DTR
RX
TX
0V
A
B
0V
Shield
120R Resistor
on last Controller.
A B 0V
NETWORK PRINTER
ACTWin Software
12V DC
Power
Supply
(300mA) +12V
0V
1 +12V
2 0V & Shield
3 B
4 A
Pin Function
RS-485 Bus
RS-232
1. From the Controller keypad Enter Installer Menu->Communications and set a unique address
for each controller on the network. Set Direct Connect to No.
2. From ACTWin create a new database. In the database creation wizard check RS-485
Automatic Interface. This setting is also available from View->Options->Comms.
3. Connect to the controllers from ACTWin. The LED on the RS485 converter should blink
rapidly indicating communications in progress.
18-00023
Downloaded from: http://www.guardianalarms.net