P 1
T H
V F 2
M K P 2
M K P 1
M K 2
DKP
I D 1 1
I D 1 2
M K 1
Legend
AF Outdoor sensor
ID .. Zone Unit
VF1 Flow sensor
Floor heating
TH Security aquastatic
Floor heating
P1 Pump DHW
DKP Pump 1 Radiators
MKP1 Pump 1 Floor heating
MKP2 Pump 2 Floor heating
MK1 Mixing tab 1
Floor heating
MK2 Mixing tab 2
Floor heating
APPLICATION 3
APPLICATION 4
Description:
- This configuration offers a simple means of
controlling two heating circuits (radiators or under-
floor heating) with a Room Unit which remotely
controls both circuits
- These circuits can be regulated differently as a
function of climatic conditions
- This configuration is ideal for a basic under-floor
heating system, complemented by radiators
- - In this case it is possible to choose from among
various heating functions, allowing up to 3 weekly
programmes for heating but also the hot water
circuit
- The internal ESYS control system automatically
detects the optional external probe. In this
configuration the boiler constantly adapts its
functioning to the external temperature
- For the Prestige Solo, the hot water kit is integrated
in the boiler
User Benefits:
- Maximum comfort
- Maximum efficiency
- Simple and economical start up of second circuit
- Delivered with hydraulic kit
- Information on the system status are indicated on the
LCD
* Expansion safety-vessel necessary for under-floor heating
circuit
Description:
- The Control Unit regulator can control up to 3
heating circuits of which at least one a direct circuit
(for example 2 seperate underfloor circuits and 1
radiator circuit)
- The Control Unit regulator can also separately control
1 hot water circuit
- The heating circuits are regulated as a function of
external conditions
- In addition an ambiant probe (RFF) or a Zone Unit
(RS) can be defined for each of the circuits
- For renovations or in certain specific cases it is
possible to use simple thermostats (ACV22)
- For more extensive applications it is possible to
combine serveral Control Unit regulators (contact us
for details)
- For the Prestige Solo, the hot water kit is integrated
in the boiler
User Benefits:
- Maximum comfort
- Maximum efficiency
- Simple and economical start up of second circuit
- Delivered with hydraulic kit
- State of the art regulation
- Large choice of functionality
- Programmable according to individual needs
* Expansion safety-vessel necessary for under-floor heating
circuit
O p s t e l l i n g E v o o r P r e s t i g e E x c e l l e n c e
N T C 4
R V
L e g e n d e
P 3
T H
V F
P 2 P 1
M 1