ADB Safegate AGLAS-C User manual

AGLAS-C Remote Control Device
(AGLAS) Remotes
Installation Manual
96A0481, Rev. A, 3/21/17

AGLAS-C Remote Control Device
DISCLAIMER / WARRANTY
© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
ii
A.0 Disclaimer / Standard Warranty
A.1 CE certification
The equipment listed as CE certified means that the product complies with the essential requirements concerning safety and
hygiene. The directives that have been taken into consideration in the design are available on written request to ADB SAFEGATE.
A.2 ETL certification
The equipment listed as ETL certified means that the product complies with the essential requirements concerning safety and FAA
Airfield regulations. The directives that have been taken into consideration in the design are available on written request to
ADB SAFEGATE.
A.3 LED Product Guarantee
Where applicable, per FAA EB67(applicable edition), ADB SAFEGATE L858(L) Airfield Guidance Signs are warranted against
electrical defects in design or manufacture of the LED or LED specific circuitry for a period of 4 years. ADB SAFEGATE LED light
fixtures (with the exception of obstruction lighting) are warranted against mechanical and physical defects in design or
manufacture for a period of 12 months from date of installation; and are warranted against electrical defects in design or
manufacture of the LED or LED specific circuitry for a period of 4 years per FAA EB67 (applicable edition).
NOTE: See your sales order contract for a complete warranty description. In some specific cases, deviations are (to be) accepted in
the contract, which will supersede the standard warranty.
A.4 Standard Product Guarantee
Products of ADB SAFEGATE manufacture are guaranteed against mechanical, electrical, and physical defects (excluding lamps)
which may occur during proper and normal use for a period of one year from the date of installation or 2 years from date of
shipment and are guaranteed to be merchantable and fit for the ordinary purposes for which such products are made. ADB
SAFEGATE L858 Airfield Guidance Signs are warranted against mechanical and physical defects in design or manufacture for a
period of 2 years from date of installation per FAA AC 150/5345-44 (applicable edition).
NOTE: See your sales order contract for a complete warranty description.
A.5 All Products
LED Products of ADB SAFEGATE, manufactured and sold by ADB SAFEGATE or its licensed representatives, meets the
corresponding requirements of FAA, ICAO and IEC.
ADB SAFEGATE will correct by repair or replacement per the applicable guarantee above, at its option, equipment or parts which
fail because of mechanical, electrical or physical defects, provided that the goods have been properly handled and stored prior to
installation, properly installed and properly operated after installation, and provided further that Buyer gives ADB SAFEGATE
written notice of such defects after delivery of the goods to Buyer. Refer to the Safety section for more information on Material
Handling Precautions and Storage precautions that must be followed.
ADB SAFEGATE reserves the right to examine goods upon which a claim is made. Said goods must be presented in the same
condition as when the defect therein was discovered. ADB SAFEGATE furthers reserves the right to require the return of such
goods to establish any claim.
ADB SAFEGATE’s obligation under this guarantee is limited to making repair or replacement within a reasonable time after receipt
of such written notice and does not include any other costs such as the cost of removal of defective part, installation of repaired
product, labor or consequential damages of any kind, the exclusive remedy being to require such new parts to be furnished.
ADB SAFEGATE’s liability under no circumstances will exceed the contract price of goods claimed to be defective. Any returns
under this guarantee are to be on a transportation charges prepaid basis. For products not manufactured by, but sold by ADB
SAFEGATE, warranty is limited to that extended by the original manufacturer.
This is ADB SAFEGATE’s sole guarantee and warranty with respect to the goods; there are no express warranties or warranties of
fitness for any particular purpose or any implied warranties of fitness for any particular purpose or any implied warranties other
than those made expressly herein. All such warranties being expressly disclaimed.

© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
iii
AGLAS-C Remote Control Device
DISCLAIMER / WARRANTY
A.6 Liability
ADB SAFEGATE cannot be held responsible for injuries or damages resulting from non-standard, unintended uses of its
equipment. The equipment is designed and intended only for the purpose described in the manual. Uses not described in the
manual are considered unintended uses and may result in serious personal injury, death or property damage.
Unintended uses includes the following actions:
— Making changes to equipment that have not been recommended or described in this manual or using parts that are not
genuine ADB SAFEGATE replacement parts or accessories.
— Failing to make sure that auxiliary equipment complies with approval agency requirements, local codes, and all applicable
safety standards if not in contradiction with the general rules.
— Using materials or auxiliary equipment that are inappropriate or incompatible with your ADB SAFEGATE equipment.
—Allowing unskilled personnel to perform any task on or with the equipment.
WARNING
Use of the equipment in ways other than described in the catalogue leaflet and the manual may result in
personal injury, death, or property and equipment damage. Use this equipment only as described in the
manual.

AGLAS-C Remote Control Device
DISCLAIMER / WARRANTY
© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
iv
A.7 © ADB SAFEGATE BVBA
This manual or parts thereof may not be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
electronic, mechanical, photocopying, recording, nor otherwise, without ADB SAFEGATE BVBA’s prior written consent.
This manual could contain technical inaccuracies or typographical errors. ADB SAFEGATE BVBA reserves the right to revise this
manual from time to time in the contents thereof without obligation of ADB SAFEGATE BVBA to notify any person of such revision
or change. Details and values given in this manual are average values and have been compiled with care. They are not binding,
however, and ADB SAFEGATE BVBA disclaims any liability for damages or detriments suffered as a result of reliance on the
information given herein or the use of products, processes or equipment to which this manual refers. No warranty is made that the
use of the information or of the products, processes or equipment to which this manual refers will not infringe any third party’s
patents or rights. The information given does not release the buyer from making their own experiments and tests.

© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
v
AGLAS-C Remote Control Device
TABLE OF CONTENTS
A.0: Disclaimer / Standard Warranty.............................................................................................................II
1.0: Safety ......................................................................................................................................................................1
1.1 :HAZARD Icons used in the manual ....................................................................................................... 1
1.2 :To use this equipment safely ................................................................................................................... 2
2.0: AGLAS Remote ..................................................................................................................................................5
2.1 :Manual Introduction .................................................................................................................................. 5
2.1.1 :How to work with the manual .........................................................................................................................5
2.1.2 :Record of changes .............................................................................................................................................5
2.2 :AGLAS Remote Introduction .................................................................................................................. 6
2.2.1 :General ..................................................................................................................................................................6
2.2.2 :Illustration .............................................................................................................................................................6
2.2.3 :Checking the Device ..........................................................................................................................................7
2.2.4 :View of the device with connections .............................................................................................................8
2.2.5 :View of the device with connections .............................................................................................................9
2.2.6 :Construction ......................................................................................................................................................10
2.2.7 :Theory of Operation .......................................................................................................................................11
2.3 :Installation .................................................................................................................................................. 13
2.3.1 :Installation in a Transformer Pit ....................................................................................................................13
2.3.2 :Connection to the Series Transformer and the Light Fitting(s) .............................................................14
2.3.3 :Utility Remote Enclosure Wiring Diagram ..................................................................................................15
2.3.4 :Earth Grounding ...............................................................................................................................................16
2.3.5 :Safety Instructions ............................................................................................................................................16
2.3.6 :Replacing an AGLAS Remote ........................................................................................................................17
2.4 :Modes of Operation of an AGLAS Remote ...................................................................................... 18
2.4.1 :Frequency Scan .................................................................................................................................................18
2.4.2 :Operating Mode ...............................................................................................................................................18
2.4.3 :Switch Status of the Connected Lights .......................................................................................................19
2.4.4 :Switch Status under Special Circumstances ...............................................................................................19

AGLAS-C Remote Control Device
© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
vi
2.4.5 :Spreadsheet ...................................................................................................................................................... 20
2.5 :Technical Specifications ..........................................................................................................................21
2.5.1 :AGLAS Specifications ...................................................................................................................................... 21
2.5.2 :Circuit Specifications ....................................................................................................................................... 22
3.0: Parts .......................................................................................................................................................................23
3.1 :Spare Components ..................................................................................................................................23
3.2 :Terms ...........................................................................................................................................................24

© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
1
AGLAS-C Remote Control Device
Safety
1.0 Safety
This section contains general safety instructions for installing and using ADB Airfield Solutions equipment. Some safety
instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections
of this manual where appropriate.
1.1 HAZARD Icons used in the manual
For all HAZARD symbols in use, see the Safety section. All symbols must comply with ISO and ANSI standards.
Carefully read and observe all safety instructions in this manual, which alert you to safety hazards and conditions that may result
in personal injury, death or property and equipment damage and are accompanied by the symbol shown below.
1.1.1 Qualified Personnel
WARNING
• Failure to observe a warning may result in personal injury, death or equipment damage.
DANGER - RISK OF ELECTRICAL SHOCK OR ARC FLASH
• Disconnect equipment from line voltage. Failure to observe this warning may result in personal injury, death,
or equipment damage. ARC Flash may cause blindness, severe burns or death.
WARNING - WEAR PERSONAL PROTECTIVE EQUIPMENT
• Failure to observe may result in serious injury.
WARNING - DO NOT TOUCH
• Failure to observe this warning may result in personal injury, death, or equipment damage.
CAUTION
• Failure to observe a caution may result in equipment damage.
IMPORTANT INFORMATION
The term qualified personnel is defined here as individuals who thoroughly understand the equipment and its safe operation, maintenance and
repair. Qualified personnel are physically capable of performing the required tasks, familiar with all relevant safety rules and regulations and have
been trained to safely install, operate, maintain and repair the equipment. It is the responsibility of the company operating this equipment to
ensure that its personnel meet these requirements.
ALWAYS USE REQUIRED PERSONAL PROTECTIVE EQUIPMENT (PPE) AND
FOLLOW SAFE ELECTRICAL WORK PRACTICE.

AGLAS-C Remote Control Device
To use this equipment safely
© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
2
1.2 To use this equipment safely
1.2.1 Additional Reference Materials
1.2.2 Intended Use
1.2.3 Fasteners
WARNING
Read installation instructions in their entirety before starting installation.
• Become familiar with the general safety instructions in this section of the manual before installing, operating, maintaining or repairing this
equipment.
• Read and carefully follow the instructions throughout this manual for performing specific tasks and working with specific equipment.
• Make this manual available to personnel installing, operating, maintaining or repairing this equipment.
• Follow all applicable safety procedures required by your company, industry standards and government or other regulatory agencies.
• Install all electrical connections to local code.
• Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All wiring must meet local codes.
• Route electrical wiring along a protected path. Make sure they will not be damaged by moving equipment.
• Protect components from damage, wear, and harsh environment conditions.
• Allow ample room for maintenance, panel accessibility, and cover removal.
• Protect equipment with safety devices as specified by applicable safety regulations.
• If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper functioning
prior to returning power to the circuit.
Failure to follow these warnings may result in serious injury or equipment damage.
IMPORTANT INFORMATION
• IEC - International Standards and Conformity Assessment for all electrical, electronic and related technologies
• IEC 60364 - Electrical Installations in Buildings
• FAA Advisory: AC 150/5340-26 (current edition) Maintenance of Airport Visual Aid Facilities
• ANSI/NFPA 79, Electrical Standards for Metalworking Machine Tools.
• National and local electrical codes and standards.
WARNING
IMPROPER USE
Using this equipment in ways other than described in this manual may result in personal injury, death or property and equipment damage. Use
this equipment only as described in this manual.
Failure to follow these warnings may result in serious injury or equipment damage.
WARNING
FOREIGN OBJECT DAMAGE - FOD
• Only use fasteners of the same type as the one originally supplied with the equipment.
• Always tighten the fasteners to the recommended torque. Use a calibrated torque wrench and apply the recommended adhesive type.
• Obey the instructions of the adhesives necessary for the fasteners.
Failure to follow these warnings may cause the fasteners to loosen, damage the equipment, potentially to
loosen the equipment. This can lead to a highly dangerous situation of FOD, with potential lethal
consequences.

© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
3
AGLAS-C Remote Control Device
To use this equipment safely
1.2.4 Operation
1.2.5 Storage
1.2.6 Material Handling Precautions
CAUTION
IMPROPER OPERATION
• Only qualified personnel, physically capable of operating the equipment and with no impairments in their judgment or reaction times, should
operate this equipment.
• Read all system component manuals before operating this equipment. A thorough understanding of system components and their operation
will help you operate the system safely and efficiently.
• Before starting this equipment, check all safety interlocks, fire-detection systems, and protective devices such as panels and covers. Make
sure all devices are fully functional. Do not operate the system if these devices are not working properly. Do not deactivate or bypass
automatic safety interlocks or locked-out electrical disconnects or pneumatic valves.
• Protect equipment with safety devices as specified by applicable safety regulations.
• If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper
functioning.
• Route electrical wiring along a protected path. Make sure they will not be damaged by moving equipment.
• Never operate equipment with a known malfunction.
• Do not attempt to operate or service electrical equipment if standing water is present.
• Use this equipment only in the environments for which it is rated. Do not operate this equipment in humid, flammable, or explosive
environments unless it has been rated for safe operation in these environments.
• Never touch exposed electrical connections on equipment while the power is ON.
Failure to follow this instruction can result in equipment damage.
CAUTION
IMPROPER STORAGE
If equipment is to be stored prior to installation, it must be protected from the weather and kept free of condensation and dust.
Failure to follow this instruction can result in equipment damage
CAUTION
ELECTROSTATIC SENSITIVE DEVICES
This equipment may contain electrostatic sensitive devices.
• Protect from electrostatic discharge.
• Electronic modules and components should be touched only when this is unavoidable e.g. soldering, replacement.
• Before touching any component of the cabinet you should bring your body to the same potential as the cabinet by touching a conductive
earthed part of the cabinet.
• Electronic modules or components must not be brought in contact with highly insulating materials such as plastic sheets, synthetic fiber
clothing. They must be laid down on conductive surfaces.
• The tip of the soldering iron must be grounded.
• Electronic modules and components must be stored and transported in conductive packing.
Failure to follow this instruction can result in equipment damage

AGLAS-C Remote Control Device
To use this equipment safely
© ADB SAFEGATE All Rights Reserved
96A0481 Rev. A
4
1.2.7 Action in the Event of a System or Component Malfunction
1.2.8 Maintenance
1.2.9 Maintenance and Repair
WARNING
UNSTABLE LOAD
• Use extreme care when moving heavy equipment.
• Verify that the moving equipment is rated to handle the weight.
• When removing equipment from a shipping pallet, carefully balance and secure it using a safety strap.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
WARNING
ELECTRIC SHOCK HAZARD
• Do not operate a system that contains malfunctioning components. If a component malfunctions, turn the system OFF immediately.
• Disconnect and lock out electrical power.
• Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component according to instructions provided in its
manual.
Failure to follow these warnings will result in death or equipment damage.
DANGER
ARC FLASH AND ELECTRIC SHOCK HAZARD
Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks.
• Only persons who are properly trained and familiar with ADB Airfield Solutions equipment are permitted to service this equipment.
• An open airfield current circuit is capable of generating >5000 Vac and may appear OFF to a meter.
• Never unplug a device from a constant current circuit while it is operating. Arc flash may result.
• Disconnect and lock out electrical power.
• Always use safety devices when working on this equipment.
• Follow the recommended maintenance procedures in the product manuals.
• Do not service or adjust any equipment unless another person trained in first aid and CPR is present.
• Connect all disconnected equipment ground cables and wires after servicing equipment. Ground all conductive equipment.
• Use only approved ADB Airfield Solutions replacement parts. Using unapproved parts or making unapproved modifications to equipment may
void agency approvals and create safety hazards.
• Check the interlock systems periodically to ensure their effectiveness.
• Do not attempt to service electrical equipment if standing water is present. Use caution when servicing electrical equipment in a high-humidity
environment.
• Use tools with insulated handles when working with airfield electrical equipment.
Failure to follow these warnings will result in death or equipment damage.

© ADB SAFEGATE All Rights Reserved
5
2.0 AGLAS Remote
AGLAS®Remotes – User Manual
General notice: other product names used here are for identification purposes only and may be trademarks of their respective
companies.
2.1 Manual Introduction
•This document provides detailed information how to correctly install and maintain Airfield Ground Lighting Automation
System (AGLAS) remotes.
2.1.1 How to work with the manual
1. Be familiar with the structure and content.
2. Carry out the actions completely and in the given sequence.
2.1.2 Record of changes
Page Rev Description Checked Approved Date
A AGLAS-C 3/9/17

AGLAS-C Remote Control Device
AGLAS Remote Introduction
© ADB SAFEGATE All Rights Reserved
6
96A0481 Rev. A
2.2 AGLAS Remote Introduction
2.2.1 General
The AGLAS Remotes are intelligent powerline addressable field devices that operate on the secondary side of airfield isolation
transformers. They serve as slave nodes in a master/slave network that is controlled by a AGLAS Master. The AGLAS Remote is
available in the following four versions:
— AGLAS Remote single channel
for controlling one light (airfield ground lighting)
— AGLAS Remote dual channel
for controlling two lights (airfield ground lighting)
— AGLAS Remote RGL single channel
for network-synchronized blinking after switching on, without master synchronization (Runway Guard Light)
— AGLAS Remote RGL dual channel
for continuous, network-synchronized, alternating blinking of both channels after switching on, without master
synchronization (Runway Guard Light)
In terms of construction, they differ in the number of channels which in turn determines the number of lights that can be
switched.
RGL Remotes leave the factory with a special configuration that ensures synchronous start-up after power-up of the regulator and
network-synchronized blinking without master synchronization. The factory setting also includes the choice whether the blinking
is to start with “initial flash On” or “Off”. This option makes it possible to have different groups of Remotes flash alternately,
leveling the load on the constant current regulator caused by synchronous switching of all groups of Remotes.
In the following sections all four devices will be referred to as AGLAS Remotes.
2.2.2 Illustration
Figure 1: AGLAS Remote single

© ADB SAFEGATE All Rights Reserved
7
2.2.3 Checking the Device
2.2.3.1 Scope of Supply
The AGLAS-C Remote single channel is supplied with two 12-inch (30 cm) cord-set cables for connection to the series transformer
and the light.
The AGLAS-C Remote dual channel is supplied with three 12-inch (30 cm) cord-set cables, 1 for connection to the series
transformer and 2 for connection to the lights.
The AGLAS-C Remote single channel RGL is supplied with two 12-inch (30 cm) cord-set cables for connection to the series
transformer and the light, adjusted at the factory for configured start-up after switching on (consistent adjustment for all RGL
Remotes in a project).
The AGLAS-C Remote dual channel RGL is supplied with three 12-inch (30 cm) cord-set cables, 1 for connection to the series
transformer and 2 for connection to the lights; adjusted at the factory for configured start-up after switching on.
See “Parts” on page 23” for the complete list of remote variants.
2.2.3.2 Unpacking
The device has been fully assembled, tested and packed at the factory and has no internal transport locks.
2.2.3.3 Inspection
The delivery must be checked to make sure that it is complete and in perfect condition. The supplier must be notified of any
complaints within 2 weeks. After this period, complaints about the delivery will not be accepted. In the event of the goods being
returned, the same transport packaging must be used. See Figure 2.
The number on the nameplate must be checked against the order number on the delivery note.
The nameplate is located on the side of the device (example: AGLAS-C Remote single channel).
Figure 2: Nameplate of the AGLAS Remote Duel Channel
For commissioning, the serial number on the nameplate (e.g. serial number 4015000220,
see Figure 2) must be recorded. This is then utilized for installation and configuration.

AGLAS-C Remote Control Device
AGLAS Remote Introduction
© ADB SAFEGATE All Rights Reserved
8
96A0481 Rev. A
2.2.3.4 Storage
When storing the device, it is advisable to leave it in its original packaging. The storage temperature is shown in “Technical
Specifications” on page 21.
Storage Temperature: Remote: -67°F to +167°F (-55°C to +75°C)
2.2.4 View of the device with connections
Figure 3: View of the AGLAS Remote Dual Channel
1. Cable with 2-pin plug (in compliance with FAA L-823) for connection to the series circuit isolation transformer (X3)
2. Cable with 2-pin socket (in compliance with FAA L-823) for connection to the light on channel A (X1)
3. Cable with 2-pin socket (in compliance with FAA L-823) for connection to the light on channel B (for dual Remote only) (X4)
4. Ground cable connection (X2)
5. AGLAS Remote housing
6. AGLAS Remote Label for Remote ID number.
NOTE: See nameplate of AGLAS Remote (Figure 2) for identification of connections
marked “X”.
5. AGLAS Remote Dual
Channel
Remote
ID Label
X1
Ground Screw
(X2)
X4 X3

© ADB SAFEGATE All Rights Reserved
9
2.2.5 View of the device with connections
Figure 4: View of the AGLAS Utility Remote Cabinet
NOTE: See the remote cabinet wiring diagram for connections.
508 (20)
615(24)
229
(9)
60A4562
ILCMS UTILITY REMOTE MACH ENCLOSURE
85A0123/1
HOLE SEAL, (through back wall)
73A0136-31
L823 CORDSET, STYLE 6, LED ELEVATED
44A7509/1
ILCMS REMOTE UTILITY PCB ASSEMBLY
1593.17.300
ILCMS COMM PCB ASSY.
SUPPORT CHANNEL
1832-2B
L867B HD BASE PLT RGL 3/8X12
62B0064
COUPLING 2" FRANGIBLE THRD 1 END
INSTALL M8 FLANGE NUT
RM0251
MTG RAIL 7.5MM U-SHAPE X 13 IN
72A0223-5
TERM BLK 22-10AWG 600V BLUE 6mm
72A0223-2
TERM BLK 22-10AWG 600V WHITE 6mm
72A0223-3
TERM BLK 22-10AWG 600V BLACK 6mm
72A0219
TRM BLK GND'NG GRN/YEL 24-12AWG 6mm
WITH GROUNDING WASHER

AGLAS-C Remote Control Device
AGLAS Remote Introduction
© ADB SAFEGATE All Rights Reserved
10
96A0481 Rev. A
2.2.6 Construction
The AGLAS Remote is sealed to make it watertight and gas-tight and must not be opened.
NOTE: Once the Remote has been opened, the warranty is void.
A defective or open Remote must be returned to the manufacturer.
2.2.6.1 Block diagram
Figure 5: Block diagram of the AGLAS Remote dual
Overvoltage
Protection
Powerline
Coupling
Filter Power
Supply
Lamp
Switch
Overvoltage
Protection
Transformer
Earth Ground
Screw
X1
X2
X4
X3
LampA
Lamp B
Remote Controller
Receive Transmit
Communication
Processor
Micro-
controller
Input/
Output
Power
Zero crossing
of current
Earth
Ground Screw

© ADB SAFEGATE All Rights Reserved
11
2.2.7 Theory of Operation
Background Information: AGLAS uses power line carrier technology to communicate between controlling units on an airfield
lighting series circuit. A AGLAS system typically consists of one high voltage modem, or Master, connected with the Constant
Current Regulator (CCR) powering the airfield lighting circuit and many slave units, or Remotes, collocated with individual lights in
the field. A typical AGLAS topology is provided in Figure 6.
Figure 6: Typical AGLAS Topology
2.2.7.1 Architecture
Figure 7 depicts the general nature of the system components and their interactions. The “Control System”, shown in grey, is an
external ALCMS system that provides controlling commands and digests Master and Fixture status reports. There is typically only
one control system in the architecture. The “Master”, shown in blue, is the high voltage modem that communicates commands to
and receives status from the fixtures. There can be many masters in a given system. Masters digest commands from the control
system and provide status to it. Masters also communicate amongst themselves to maintain communication timing
synchronization. Each master communicates with the fixtures on its respective circuit.
Legend
Commands from ATC (Fiber Optic)
Field communication (Ethernet)
Power line
Dual
Remote

AGLAS-C Remote Control Device
AGLAS Remote Introduction
© ADB SAFEGATE All Rights Reserved
12
96A0481 Rev. A
Figure 7: Series Circuit Master / Fixture Architecture
Control
System
Status
Commands
Master
Fixtures
Fixtures
Fixtures
Fixtures
Status
Commands
Master
Fixtures
Fixtures
Fixtures
Fixtures
Status
Commands
Commands
Status
Synchronization

© ADB SAFEGATE All Rights Reserved
13
2.3 Installation
Installation is identical for all AGLAS Remote versions.
Figure 8: Diagram of AGLAS installation in series circuit
2.3.1 Installation in a Transformer Pit
The orientation required for installation is indicated by the labeling on the nameplate.
This ensures optimum heat dissipation through the housing. If the device is installed by suspension, free air circulation must be
provided for the AGLAS Remote.
NOTE: If several AGLAS Remotes are installed in a single pit, they should be spaced with a distance of at least 2-inch (50mm) from
each other and from the series transformers to have optimum communication signal separation. Because the communication
signal is coupled magnetically, the distance between the transformers should also not be less than 2-inch (50mm).
Minimum distance between remote cable feed-through and pit walls is 2-inch (50 mm).
Figure 9: Remote max. bending radius
1. Light Fixture 5. Remote Input Plug (TRANSFORMER)
2. Light Fixture Plug 6. Transformer Secondary Receptacle
3. Remote Output Receptacle (LAMP) 7. Primary Series Circuit
4. Remote 8. L-830/L-831 Isolation Transformer
1
23
5
6
7
8
Earth
Ground
2-inch (50 mm)
radius

AGLAS-C Remote Control Device
Installation
© ADB SAFEGATE All Rights Reserved
14
96A0481 Rev. A
2.3.2 Connection to the Series Transformer and the Light Fitting(s)
The 2-pin plug on cable X1 is connected to the socket for the secondary circuit of the series transformer. The light(s) is/are
connected to the 2-pin socket(s) of the cable(s) X3 (and X4 for the dual AGLAS Remote).
All plug connections must be sealed with self-bonding insulation tape or using “heat shrink” sleeves.
To improve watertightness, an optional watertight heat shrink sleeve can be installed at the junction of the plug and receptacle:
(see Figure 10)
Figure 10: Connection to series transformer and light fitting
Step 1:
Place the heat shrink sleeve over the light inset plug wire.
Step 2:
Connect the inset light plug to the Remote receptacle designated CHANNEL A (and CHANNEL B if used).
Step 3:
Pull the heat shrink sleeve over the plug-to-receptacle connection. Heats shrink the sleeve.
Repeat steps 1 through 3 for the Remote plug designated TRANSFORMER and the transformer secondary receptacle.
Watertight heat shrink sleeve
Plug and Receptacle
Step 3
Step 2
Step 1
Table of contents