ADF Web HD67324-B2-E-232-4GB User manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 1 of 44
User Manual
Revision 1 200
English
Modbus / CAN – Datalogger
(Order Code: HD67324-B2-E-232-4GB, HD67324-B2-E-485-
4GB,
HD67324-B2-E-CAN-4GB)
for Website information:
www adfweb com?Product=HD67324
for Price information:
www adfweb com?Price=HD67324-B2-E-232-4GB
www adfweb com?Price=HD67324-B2-E-485-4GB
www adfweb com?Price=HD67324-B2-E-CAN-4GB
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
For other M-Bus products:
See also the following link:
Converter M-Bus to
www adfweb com?Product=HD67021 (RS232
www adfweb com?Product=HD67022 (RS485
www adfweb com?Product=HD67030 (Ethernet
Extender and Repeater, M-Bus
www adfweb com?Product=HD67032
Gateway M-Bus / Modbus RTU
www adfweb com?Product=HD67029M-232 (on RS232
www adfweb com?Product=HD67029M-485 (on RS485
Gateway M-Bus / Modbus TCP
www adfweb com?Product=HD67044-B2
Gateway M-Bus / CANopen
www adfweb com?Product=HD67051
Gateway M-Bus / PROFIBUS
www adfweb com?Product=HD67053M
Do you have an your customer protocol?
See the following link:
www adfweb com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www adfweb com?Cmd=helpme
User Manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 2 of 44
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
CONNECTION SCHEME 4
CONFIGURATION 7
CHARACTERISTICS 7
POWER SUPPLY 8
FUNCTION MODES 9
LEDS 10
RS232 12
RS485 13
CAN 14
ETHERNET 15
USE OF SW67324 16
NEW CONFIGURATION 17
LOAD CONFIGURATION 18
SAVE CONFIGURATION 19
UPDATE DEVICE 20
SOFTWARE PREFERENCES 23
CONFIGURATION SETTING 24
DOWNLOAD DATA 32
DATE & TIME SETTINGS 34
WEBSERVER INTERFACE 35
MECHANICAL DIMENSIONS 40
ORDERING INFORMATIONS 41
ACCESSORIES 42
DISCLAIMER 43
OTHER REGULATIONS AND STANDARDS 43
WARRANTIES AND TECHNICAL SUPPORT 44
RETURN POLICY 44
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document
With this “Document Code” go to web page www adfweb com/download/ and
search for the corresponding code on the page Click on the proper “Document
Code” and download the updates
REVISION LIST:
Revision Date Author
Chapter
Description
1 002 07/02/2013
Nt All Added new chapters
1 003 20/05/2013
Fl All Add USB driver location
1 100 23/12/2015
Ff All Added Ethernet version
1 200 22/12/2017
Ff All Added CAN version
WARNING:
ADFweb com reserves the right to change information in this manual about
our product without warning
ADFweb com is not responsible for any error this manual may contain
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 3 of 44
SECURITY ALERT:
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual When using the device, legal and
safety regulation are required for each individual application The same applies also when using accessories
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i e
independent limit switches, mechanical interlocks, etc )
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage
CE
CONFORMITY
The declaration is made by our company You can send an email to support@adfweb com or give us a call if you need it

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 4 of 44
CONNECTION SCHEME:
Figure 1a: Connection scheme for HD67324-B2-E-232-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 5 of 44
Figure 1b: Connection scheme for HD67324-B2-E-485-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 6 of 44
Figure 1b: Connection scheme for HD67324-B2-E-CAN-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 7 of 44
CHARACTERISTICS:
The HD67324 is a Modbus / CAN Datalogger
It has the following characteristics:
Electrical isolation for bus (RS232, RS485, CAN, Ethernet) connection;
Mountable on Rail DIN;
Power Supply 8…24V AC or 12…35V DC;
Temperature range -20°C to 70°C
CONFIGURATION:
You need Compositor SW67324 software on your PC in order to perform the following:
Define the parameter of Modbus line;
Set Time and Date;
Manage the Datalogger’s functions;
Update the device

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 8 of 44
POWER SUPPLY:
The devices can be powered at 8…24V AC and 12…35V DC For more details see the two tables below
VAC
VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V
Consumption at 24V DC:
Device Consumption [W/VA]
HD67324-B2-E-232/485-xGB 3 5
HD67324-B2-E-CAN-xGB 3 5
HD67324-B2-E-232/485-xGB
HD67324-B2-E-CAN-xGB
Caution: Not reverse the polarity power

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 9 of 44
FUNCTION MODES:
HD67324-B2-E-xxx-xGB
The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’:
The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of
the device
The second, with ‘Dip1 of Dip-Switch A’ at “ON” position, is used for upload the Project
and/or Firmware
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section
According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 10 of 44
LEDS:
HD67324-B2-E-232-xGB
HD67324-B2-E-485-xGB
The device has got five LEDs that are used to give information of the functioning status
The various meanings of the LEDs are described in the table below
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
2: Ethernet communication
(yellow) Blinks when Ethernet request is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
3: Modbus communication
(yellow) Blinks when Modbus frame (RS232/RS485) is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
4: Modbus error (yellow)
ON: At least one Modbus request hasn’t a correct
response
OFF: No errors are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
5: Ethernet Link (green) ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 11 of 44
HD67324-B2-E-CAN-xGB
The device has got five LEDs that are used to give information of the functioning status
The various meanings of the LEDs are described in the table below
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
2: Ethernet communication
(yellow) Blinks when Ethernet request is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
3: CAN communication
(yellow) Blinks when a CAN frame is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
4: Not used (yellow) OFF Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
5: Ethernet Link (green) ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 12 of 44
RS232:
The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a
serial cable where the pins 2 and 3 are crossed)
It is recommended that the RS232 cable not exceed 15 meters

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 13 of 44
RS485:
For terminate the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure
The maximum length of the cable should be 1200m (4000 feet)
Here some codes of cables:
Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield;
Belden p/n 82842 - 2x 24AWG stranded twisted pairs conductor + foil shield + braid shield;
Tasker: p/n C521 - 1x 24AWG twisted pair conductor + foil shield + braid shield;
Tasker: p/n C522 - 2x 24AWG twisted pairs conductor + foil shield + braid shield

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 14 of 44
CAN:
For terminating the CAN line with a 120Ω resistor it is necessary to put Dip1 of ‘Dip-Switch C’ at ON position
Cable characteristics:
DC parameter: Impedance
70 Ohm/m
AC parameters: Impedance
120 Ohm/m
Delay 5 ns/m
Length
Baud
Rate
[bps]
Length MAX [m]
10 K 5000
20 K 2500
50 K 1000
100 K 650
125 K 500
250 K 250
500 K 100
800 K 50
1000 K 25

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 15 of 44
ETHERNET:
The Ethernet port is used for programming the device and managing the functions
The Ethernet connection must be made using Connector2 of HD67324-B2-E-xxx-xGB with at least a Category 5E cable The maximum length
of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To
connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC is recommended the use of a
cross cable

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 16 of 44
USE OF COMPOSITOR SW67324:
To configure the Datalogger, use the available software that runs with Windows called SW67324 It is downloadable on the site
www adfweb com and its operation is described in this document (This manual is referenced to the last version of the software present on
our web site) The software works with MSWindows (XP, Vista, Seven, 8, 10; 32/64bit)
When launching the SW67324, the window below appears (Fig 2)
Note:
It is necessary to have installed Net Framework 4
Figure 2: Main window for SW67324

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 17 of 44
Figure 3: “New Configuration” window
NEW CONFIGURATION:
By pressing the “New Configuration” button it is possible to
create a new project It is possible to assign the name and
confirm it by pressing the “OK” button

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 18 of 44
LOAD CONFIGURATION:
By pressing the “Load Configuration” button it is possible to
load an existing project by selecting one of the list that
appears
A configuration can be imported or exported too:
To clone the configurations of a DataLogger in order to
configure another device in the same manner, it is
necessary to maintain the folder and all its contents;
To clone a project in order to obtain a different version
of the project, it is sufficient to duplicate the project
folder with another name and open the new folder with
the button “Load Configuration”
Figure
4
:
“Load Configuration” window

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 19 of 44
SAVE CONFIGURATION:
By pressing the “Save Configuration” button it is possible to
save the project
There are two possibilities: saving the current configuration,
by pressing the button “Save” or saving it with a new name
by pressing the button ”Save As...” and writing the name in
the field above the button
Figure
5
:
“Save Configuration” window

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 20 of 44
UPDATE DEVICE:
By pressing the “Update Device” button it is possible to load
the created Configuration into the device; and also the
Firmware, if is necessary
If the Ethernet version is used, in order to load the parameters
or update the firmware in the device, follow these instructions:
Turn OFF the Device;
Put Dip1 of ‘Dip-Switch A’ in ON position;
Turn ON the device
Connect the Ethernet cable;
Insert the IP “192.168.2.205”;
Select which operations you want to do;
Press the “Update Device” button to start the upload;
When all the operations are “OK” turn OFF the Device;
Put Dip1 of ‘Dip-Switch A’ at OFF position;
Turn ON the device
If you know the actual IP address of the device, you have to use this procedure:
Turn ON the Device with the Ethernet cable inserted;
Insert the actual IP of the Converter;
Select which operations you want to do;
Press the “Execute update firmware” button to start the upload;
When all the operations are “OK” the device automatically goes at Normal Mode
Figure 6a: “Update Device” window (Ethernet version)
This manual suits for next models
2
Table of contents