ADRF ADXD DAS User manual

Advanced RF Technologies, Inc.
i
ADXD DAS for MPR User Manual
Version 0.1
3116 West Vanowen St.
Burbank, CA 91505
Tel: 818-840-8131
Fax: 818-840-8138
www.adrftech.com
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
SERVICE
HOST
ADXD-H-NMS-AC
LAN1
LAN0
LAN0
AC IN 110V
REMOTE
LINK
OFF - AC - ON
BATTERY
B / H
ADXD-H-ODU
ADXD-H-ODU
UL 1 UL 2 UL 3 UL 4 UL 5 UL 6 UL 7 UL 8
DL 1 DL 2 DL 3 DL 4 DL 5 DL 6 DL 7 DL 8
RU
BTS
1
2
3
4
RU 1 RU 2 RU 3 RU 4 CPRI(BTS)
SERVICE
ADXD-R-PSU-AC
ALARM
OFF - AC - ON
AC IN
ADXD-R-ORU
SERVICE
MAIN
DAISY
GUIB / HM-SFPD-SFPOPTIC S/W
ULFBDL
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
D-SFP
M-SFP
from-M
to-D
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL

Advanced RF Technologies, Inc.
ii
Information in this document is subject to change without notice.
Advanced RF Technologies, Inc. 1996-2019.
All rights reserved.
Please send comments to:
Phone: (818) 840-8131
(800) 313-9345
Fax: (818) 840-8138
Address:
Advanced RF Technologies, Inc.
Attention: Technical Publications Department
3116 Vanowen St.
Burbank, CA 91505
USA
www.adrftech.com

Advanced RF Technologies, Inc.
iii
Revision History
Change List
Version
Change list
Contents
Version
Author
Descriptions
Date
0.1
YH Ko
Initial Release
20/12/23

Advanced RF Technologies, Inc.
iv
Table of Contents
1. Introduction ......................................................................................................................................................10
1.1 Highlights ...................................................................................................................................................10
1.2 ADXD DAS Quick View ...............................................................................................................................11
1.2.1 HE Quick View ....................................................................................................................................11
1.2.2 RU Quick View ....................................................................................................................................12
1.3 Warnings and Hazards ...............................................................................................................................12
2. Block Diagram ...................................................................................................................................................17
2.1 ADXD DAS Block Diagram ..........................................................................................................................17
2.2 ADXD-DAS Scalability .................................................................................................................................18
3. ADXD Overview.................................................................................................................................................19
3.1 Head End....................................................................................................................................................19
3.1.1 NMS (Network Management System)................................................................................................20
3.1.1.1 LEDs ..........................................................................................................................................20
3.1.1.2 Ethernet Port ............................................................................................................................21
3.1.1.3 Host/Remote Switch.................................................................................................................21
3.1.1.4 Power Connection ....................................................................................................................21
3.1.1.5 POI (ADXD-H-POI-x) ..................................................................................................................22
3.1.2 POIL (ADXD-H-POIL-x).........................................................................................................................22
3.1.2.1 LED............................................................................................................................................24
3.1.2.2 RF Ports.....................................................................................................................................24
3.1.3 Optic Distribution Unit (ODU, ADXD-H-ODU).....................................................................................24
3.1.3.1 LED............................................................................................................................................25
3.1.3.2 RF Ports.....................................................................................................................................25
3.1.3.3 Optic Ports ................................................................................................................................25
3.2 MPR (Medium Power RU)..........................................................................................................................25
3.2.1 Remote Module (RM, ADXD-R-xxx)....................................................................................................27
3.2.1.1 RM ID numbering and RF line connection scheme...................................................................27
3.2.1.2 RF port ......................................................................................................................................28
3.2.1.3 LED............................................................................................................................................28
3.2.2 Optic Remote Unit (ORU, ADXD-R-ORU) ............................................................................................28
3.2.2.1 Front port..................................................................................................................................28
3.2.2.2 LED............................................................................................................................................29
3.2.3 PSU (ADXD-R-PSU-AC) ........................................................................................................................29
3.2.3.1 Port ...........................................................................................................................................29
3.2.3.2 LED............................................................................................................................................30
3.2.3.3 AC Switch ..................................................................................................................................30
4. Cable Connection..............................................................................................................................................31

Advanced RF Technologies, Inc.
v
4.1 Head End Connection Diagrams ................................................................................................................31
4.2 Remote Unit Connection Diagrams ...........................................................................................................31
5. Mounting method.............................................................................................................................................32
5.1 Head End....................................................................................................................................................32
5.1.1 Rack Mount ........................................................................................................................................32
5.2 RU ..............................................................................................................................................................33
5.2.1 Rack Mount ........................................................................................................................................33
6. Installation ........................................................................................................................................................34
6.1 Pre-Installation Inspection.........................................................................................................................34
6.2 ADXD DAS Installation Procedure..............................................................................................................34
6.2.1 HE Installation Procedure...................................................................................................................34
6.2.1.1 Installing a ADXD DAS HE in a rack ...........................................................................................34
6.2.2 RU Installation Procedure...................................................................................................................36
6.2.3 RF coaxial cable and antenna connection ..........................................................................................38
6.3 Grounding..................................................................................................................................................38
6.4 Optic Port Cleaning....................................................................................................................................38
7. Web-GUI ...........................................................................................................................................................39
7.1 Web-GUI Setup ..........................................................................................................................................39
7.1.1 DAS system/PC Connection Using Web-GUI ......................................................................................39
7.2 Administrator/User Mode .........................................................................................................................40
7.2.1 Common .............................................................................................................................................40
7.2.1.1 Navigation Tree.........................................................................................................................40
7.2.1.2 Power Status.............................................................................................................................40
7.2.1.3 Commissioning Status...............................................................................................................40
7.2.1.4 Information...............................................................................................................................40
7.2.2 Status Tab...........................................................................................................................................42
7.2.2.1 Status –NMS ............................................................................................................................42
7.2.2.2 Status –POI...............................................................................................................................43
7.2.2.3 Status –ODU.............................................................................................................................43
7.2.2.4 Status –ORU.............................................................................................................................43
7.2.2.5 Status –RM...............................................................................................................................44
7.2.3 Control/Install Tab..............................................................................................................................45
7.2.3.1 Control/Install –NMS ...............................................................................................................45
7.2.3.2 Control/Install –POI .................................................................................................................47
7.2.3.3 Control/Install –ODU ...............................................................................................................48
7.2.3.4 Control/Install –ORU................................................................................................................50
7.2.3.5 Control/Install –RM .................................................................................................................50
7.2.4 Tools ...................................................................................................................................................51
7.2.4.1 Inventory (NMS, ODU)..............................................................................................................51

Advanced RF Technologies, Inc.
vi
7.2.4.2 Commissioning (NMS) ..............................................................................................................52
7.2.4.3 History (NMS, ODU, ORU, RM) .................................................................................................52
7.2.5 System ................................................................................................................................................52
7.2.5.1 Account.....................................................................................................................................53
7.2.5.2 Logs...........................................................................................................................................53
7.2.5.3 Updates.....................................................................................................................................54
7.2.5.4 System Information ..................................................................................................................55
7.2.5.5 Backup/Restore ........................................................................................................................55
7.2.5.6 Network Service........................................................................................................................56
7.2.5.7 SNMP ........................................................................................................................................56
7.2.6 Help ....................................................................................................................................................57
7.2.7 Logout.................................................................................................................................................57
7.3 Guest Mode ...............................................................................................................................................57
8. System-Wide Specifications..............................................................................................................................58
9. Mechanical Drawings........................................................................................................................................60
9.1 HE...............................................................................................................................................................60
9.2 RU ..............................................................................................................................................................61

Advanced RF Technologies, Inc.
vii
Figures
Figure 2-1 ADXD DAS HE Quick View (Front and Rear)........................................................................................11
Figure 2-2 ADXD DAS RU Quick View (Front and Rear) .......................................................................................12
Figure 2-1 ADXD DAS Block Diagram ...................................................................................................................17
Figure 3-1 Head End Front View ..........................................................................................................................19
Figure 3-2 ADXD-H-NMS-AC Front View..............................................................................................................20
Figure 3-3 NMS LED .............................................................................................................................................20
Figure 3-4 Ethernet Port ......................................................................................................................................21
Figure 3-5 Host/Remote Switch...........................................................................................................................21
Figure 3-6 POI front View ....................................................................................................................................22
Figure 3-7 POIL front View...................................................................................................................................23
Figure 3-8 POI LED ...............................................................................................................................................24
Figure 3-9 ADXD-H-ODU Front view ...................................................................................................................25
Figure 3-10 ADXD-H-ODU LED ...............................................................................................................................25
Figure 3-11 ODU RF Ports ......................................................................................................................................25
Figure 3-12 ODU Optic Ports..................................................................................................................................25
Figure 3-13 ADXD-R Front and Rear View..............................................................................................................26
Figure 3-14 ADXD-R-XXX (RM) Front and Rear View .............................................................................................27
Figure 3-15 RM ID numbering and RF connection between ORU and RM............................................................27
Figure 3-16 ADXD-R-ORU Front and Rear View .....................................................................................................28
Figure 3-17 ADXD-R-PSU-AC Front and Rear View ................................................................................................29
Figure 3-18 ADXD-R-PSU Front and Rear View......................................................................................................30
Figure 4-1 HE Cable connection between POIs and ODU....................................................................................31
Figure 4-2 ADXD-RU 5ands connection ...............................................................................................................31
Figure 5-1 HE Rack Mount (Front & Rear view)...................................................................................................32
Figure 5-2 RU Rack Mount Front and Rear View .................................................................................................33
Figure 6-1 HE Installation Procedure ...................................................................................................................35
Figure 6-2 RU Installation Procedure...................................................................................................................37
Figure 6-3 HE Ground Cable Connection, Protective Earthing Conductor (HE chassis rear side)........................38
Figure 6-4 RU Ground Cable Connection, Protective Earthing Conductor (RU chassis rear side) .......................38
Figure 7-1 Login screen........................................................................................................................................39
Figure 7-2 ADXD DAS General Information .........................................................................................................41
Figure 7-3 SNMP ..................................................................................................................................................45
Figure 7-4 Location Setting (Install –NMS) .........................................................................................................45
Figure 7-5 Remote Ethernet Settings ..................................................................................................................46
Figure 7-6 Information.........................................................................................................................................46
Figure 7-7 Location Info / Installer Info ...............................................................................................................46
Figure 7-8 Date & Time Setting............................................................................................................................47
Figure 7-9 Account Management ........................................................................................................................53
Figure 7-10 New Account ......................................................................................................................................53
Figure 7-11 User Log..............................................................................................................................................54
Figure 7-12 System update....................................................................................................................................54
Figure 7-13 Message after System update is complete.........................................................................................55
Figure 7-14 Help.....................................................................................................................................................57
Figure 9-1 HE Drawing .........................................................................................................................................60
Figure 9-2 RU Drawing.........................................................................................................................................61

Advanced RF Technologies, Inc.
viii
Tables
Table 2-1 ADXD-DAS Scalability..........................................................................................................................18
Table 3-1 NMS LED Specifications ......................................................................................................................20
Table 3-2 POI LED Specifications ........................................................................................................................24
Table 3-3 POI RF port..........................................................................................................................................24
Table 3-4 ODU LED Specifications ......................................................................................................................25
Table 7-1 Account Information for Login ...........................................................................................................39
Table 7-2 Navigation tree ...................................................................................................................................40
Table 7-3 Power Supply Status ...........................................................................................................................40
Table 7-4 Commissioning ICON ..........................................................................................................................40
Table 7-5 System Summary Description.............................................................................................................42

Advanced RF Technologies, Inc.
9
Terms and Abbreviations
The following is a list of abbreviations and terms used throughout this document.
Abbreviation/Term
Definition
AGC Automatic Gain Control
ALC Automatic Level Control
AROMS ADRF’ Repeater Operation and Management System
BCU Band Combiner Unit
BTS Base Transceiver Station
CDMA Code Division Multiple Access
CHC Channel combiner
CW Continuous Wave (un-modulated signal)
DAS Distributed Antenna System
DL Downlink
Downlink The path covered from the Base Transceiver Station (BTS) to the subscribers’ service
area via the repeater
HE Head End
HPA High Power Amplifier
HW Hardware
IF Intermediate Frequency
LNA Low Noise Amplifier
LPR Low Power Remote Unit
LTE Long Term Evolution
MPR Medium Power Remote Unit
MS Mobile Station
NMS Network Management System
ODU Optic Donor Unit which is located in ADXD-HE.
OEU Optic Expansion Unit
ORU Optic Remote Unit which is located in ADXD-MPR.
PLL Phased Locked Loop
POI Point Of Interface
PSU Power Supply Unit
RF Radio Frequency
RU Remote Unit which is composed of ORU and RMs of plural bands
RM Remote Module which is assigned per band
SW Software
UL Uplink
Uplink The path covered from the subscribers’ service area to the Base Transceiver Station
(BTS) via the repeater
VSWR Voltage Standing Wave Ratio

Advanced RF Technologies, Inc.
10
1. INTRODUCTION
Currently the ADXD supports 600MHz, 700 MHz (Lower A, Lower B, Lower C and Upper C),
SMR800/Cellular, PCS, AWS, WCS and BRS band.
1.1 Highlights
Modular Structure (HE)
-Supports multi bands service in one body
-Supports up to 12 slot available for POI, ODU, etc.
33dBm or 37dBm of downlink composite output power
Requires only single strand of fiber per remote unit
Supports SNMP v1, v2, v3 (get, set & traps)
Web-based GUI Interface; No 3rd party GUI software required
Web-GUI connectivity via DHCP in host mode
Versatility and Usability: ADXD gives total control to the user. Control parameters such as gain, output
power, and alarm threshold can be changed using Web-GUI interface allowing the user to fine tune
the system to the given RF environment.

Advanced RF Technologies, Inc.
11
1.2 ADXD DAS Quick View
1.2.1 HE Quick View
Figure 2-1 ADXD DAS HE Quick View (Front and Rear)
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
SERVICE
HOST
ADXD-H-NMS-AC
LAN1
LAN0
LAN0
AC IN 110V
REMOTE
LINK
OFF - AC - ON
BATTERY
B / H
ADXD-H-ODU
ADXD-H-ODU
UL 1 UL 2 UL 3 UL 4 UL 5 UL 6 UL 7 UL 8
DL 1 DL 2 DL 3 DL 4 DL 5 DL 6 DL 7 DL 8
RU
BTS
1
2
3
4
RU 1 RU 2 RU 3 RU 4 CPRI(BTS)
AUX 1
AUX 3
AUX 5
AUX 7
AUX 1
AUX 3
AUX 5
AUX 7
AUX Port
Fan Unit
Ground Terminal
Network Management System
(NMS)
Point Of Interface (POI)
Optical Donor Unit (ODU)

Advanced RF Technologies, Inc.
12
1.2.2 RU Quick View
Figure 2-2 ADXD DAS RU Quick View (Front and Rear)
1.3 Warnings and Hazards
AUX 1
SERVICE
ADXD-R-PSU-AC
ALARM
OFF - AC - ON
AC IN
ADXD-R-ORU
SERVICE
MAIN
DAISY
GUIB / HM-SFPD-SFPOPTIC S/W
ULFBDL
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
D-SFP
M-SFP
from-M
to-D
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
SERVICE
ADXD-R-XXX
CPL(-30dB)
FB
UL
SERVER
DL
Optical Remote Unit
(ORU)
Remote Module
(RM)
Power Supply Unit
(PSU)
FAN Unit
AUX Port
Ground Terminal
Opening the ADXD DAS could result in electric shock and may cause
severe injury.
WARNING! ELECTRIC SHOCK
Working with the ADXD DAS while in operation, may expose the technician to RF
electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at
www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic
fields.
WARNING! EXPOSURE TO RF

Advanced RF Technologies, Inc.
13
Actual separation distance is determined upon gain of antenna used.
Please maintain a minimum safe distance of at least ϲ0 cm while operating near the donor and the server antennas.
RF EXPOSURE & ANTENNA PLACEMENT Guidelines
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
FCC WARING & ANTENNA INSTALLATION Guidance
Opening or tampering the ADXD DAS will void all warranties.
WARRANTY
Lithium Battery: CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS.
Ethernet Instructions: This equipment is for indoor use only. All cabling should be limited to
inside the building.

Advanced RF Technologies, Inc.
14
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at their own
expense.
FCC Part 15 Class A
WARNING. THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and
QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to
operate this device. Unauthorized use may result in significant forfeiture penalties, including
penalties in excess of $100,000 for each continuing violation.
FCC Part 20
Fiber optic ports of the ADXD DAS emit invisible laser radiation at the 1270, 1330nm wavelength
window.
To avoid eye injury never look directly into the optical ports, patch cords or optical cables. Do
not stare into beam or view directly with optical instruments. Always assume optical output is on.
Only technicians familiar with fiber optic safety practices and procedures should perform optical
fiber connections and disconnections of the ADXD DAS and the associated cables.
The ADXD DAS complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser
notice No.50 (July26. 2001)@IEC 60825-1, Amendment2 (Jan. 2001).
Laser Safety
Do not remove the protective covers on the fiber optic connectors until a connection is ready to be
made. Do not leave connectors uncovered when not connected.
The tip of the fiber optic connectors should not come into contact with any object or dust.
Refer to the cleaning procedure for information on the cleaning of the fiber tip.
Care of Fiber Optic Connectors

Advanced RF Technologies, Inc.
15
RSS-GEN, Sec. 7.1.2 –(transmitters)
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec
une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie
Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs,
il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.)
ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
RSS-GEN, Sec. 7.1.2 –(detachable antennas)
This radio transmitter (identify the device by certification number, or model number if Category II)has
been approved by Industry Canada to operate with the antenna types listed below with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de
modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner
avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance
requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est
supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
RF Radiation Exposure
This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of ϲ0cm between the
radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher
gain antennas require larger separation distances.
RSS-102 RF Exposure
L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance
Use of unauthorized antennas, cables, and/or coupling devices not conforming with
ERP/EIRP and/or indoor-only restrictions is prohibited.
Home/ personal use are prohibited
Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any
equipment attached to this device not meeting this standard may cause degradation and
unwanted signals in the bi-directional system. All components connected to this device must
operate in the frequency range of this device.
Only 50 ohm rated antennas, cables and passive components operating from 0.6 - 3 GHz shall
be used with this device.

Advanced RF Technologies, Inc.
16
minimum de au moinsϲ0 cm entre la source de radiation (l’antenne) et toute personne physique. Cet
appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur.

Advanced RF Technologies, Inc.
17
2. BLOCK DIAGRAM
2.1 ADXD DAS Block Diagram
Figure 2-1 ADXD DAS Block Diagram
DL1
DL3
DL5
DL7
DL2
DL4
DL6
DL8
FB1
FB3
FB5
FB7
FB2
FB4
FB6
FB8
ORU
M-SFP D-SFP
UL1
UL3
UL5
UL7
UL2
UL4
UL6
UL8
BRS
RM
FB
DL
SERVER
UL
WCS
RM
FB
DL
SERVER
UL
AWS
RM
FB
DL
SERVER
UL
PCS
RM
FB
DL
SERVER
UL
S8C
RM
FB
DL
SERVER
UL
700
RM
FB
DL
SERVER
UL
600
RM
FB
DL
SERVER
UL
PSU
MPR
MPR
DL8
DL6
DL4
DL2
DL7
DL5
DL3
DL1
UL8
UL6
UL4
UL2
UL7
UL5
UL3
UL1
ODU
RU4
RU3
RU2
RU1
HE
POI
BRS
DL/UL
UL
OUT
UL IN
DL
OUT
POI
WCS
DL/UL
UL
OUT
UL IN
DL
OUT
POI
AWS
DL/UL
UL
OUT
UL IN
DL
OUT
POI
PCS
DL/UL
UL
OUT
UL IN
DL
OUT
POI
S8C
DL/UL
UL
OUT
UL IN
DL
OUT
POI
700U
DL/UL
UL
OUT
UL IN
DL
OUT
POI
700L
DL/UL
UL
OUT
UL IN
DL
OUT
POI
600
DL/UL
UL
OUT
UL IN
DL
OUT
MPR
MPR

Advanced RF Technologies, Inc.
18
2.2 ADXD-DAS Scalability
Table 2-1 ADXD-DAS Scalability
Unit
Scalability
Remarks
Supported band
700F, Cellular, SMR800, PCS, AWS, WCS, BRS
HE
POI
No limitation in 12 slots except NMS
NMS
No limitation through NMS daisy chain link
(1 per one HE 19”Rack)
ODU
No limitation in 12 slots except NMS
In case of Aux, No limit in 8 Aux ports
MPR
RM
8 per one ORU
(6 in 19”rack and 2 in R-RACK through AUX port)
One Aux port for R-RACK
supporting 2 RMs
ORU
No limitation through ORU daisy chain link
(1 per one MPR 19”Rack)
PSU
Capable of supplying power Up to 8 RMs and 1 ORU

Advanced RF Technologies, Inc.
19
3. ADXD OVERVIEW
3.1 Head End
The head end unit always has to be connected to the Base Station using a direct cabled connection.
This system has not been approved for use with a wireless connection via server antenna to the base
station.
Specifications
-Size: 19.0 x 19.7 x 7inches (482 x 500 x 178 mm)
-Weight: 71.5lbs @8 POIs, ODU and NMS
-Power Input: 110/220VAC, -48VDC(optional)
Figure 3-1 Head End Front View
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
SERVICE
HOST
ADXD-H-NMS-AC
LAN1
LAN0
LAN0
AC IN 110V
REMOTE
LINK
OFF - AC - ON
BATTERY
B / H
ADXD-H-ODU
ADXD-H-ODU
UL 1 UL 2 UL 3 UL 4 UL 5 UL 6 UL 7 UL 8
DL 1 DL 2 DL 3 DL 4 DL 5 DL 6 DL 7 DL 8
RU
BTS
1
2
3
4
RU 1 RU 2 RU 3 RU 4 CPRI(BTS)
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS
UL IN
DL OUT
SERVICE
E911
DL/UL
ADXD-H-POI-X
ADXD-H-POI-X
UL
DL/UL
BTS
BTS

Advanced RF Technologies, Inc.
20
3.1.1 NMS (Network Management System)
Functions and features
-Supports SNMP v1, v2, and v3 (get, set & trap) and web-based GUI Interface.
-Monitors alarms and status
-Provides control interfaces with all subordinate modules
-Provides overall DAS structure via the auto tree update function
-ADXD-H-NMS-AC is for AC type
-ADXD-H-NMS-DC is for DC type
-HE’s battery backup option is available only in ADXD-H-NMS-AC
Spec
-Size: 19.0 x 12.1 x 1.7inches
-Weight: 3.5lbs
Figure 3-2 ADXD-H-NMS-AC Front View
3.1.1.1 LEDs
NMS has LEDs on the front panel as shown in Figure 3-3.
Figure 3-3 NMS LED
Table 3-1 NMS LED Specifications
ADXD DAS-NMS
Specifications
POWER
Solid Green
NMS power is ON
OFF
NMS power is OFF
LINK
Solid Red
HE Link Fail alarm exists in the system
Solid Green
No HE Link Fail alarms are present in the system
SERVICE
HOST
ADXV-H-NMS-AC
LAN1
LAN0
LAN0
AC IN 110V
REMOTE
LINK
OFF - AC - ON
BATTERY
LINKPOWER
Table of contents
Popular Storage manuals by other brands

Cybernetics
Cybernetics V Series CY-miSAN-V Operator's manual

Imation
Imation T9840 brochure

HP
HP Storevirtual 4000 Configuration guide

Seagate
Seagate BARRACUDA 4LP ST32171N/W/WC/WD/DC installation guide

Western Digital
Western Digital Caviar Green WD7500AZRX Product features

Nexto Di
Nexto Di NVS2500 Assemble & Disassembling