manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADT
  6. •
  7. CCTV Camera
  8. •
  9. ADT A-CE6TW2812UW User manual

ADT A-CE6TW2812UW User manual

Other manuals for A-CE6TW2812UW

1

Popular CCTV Camera manuals by other brands

Uniq UP-1800CL-12B user manual

Uniq

Uniq UP-1800CL-12B user manual

Hitachi Kokusai Electric SK-HD1200 operating instructions

Hitachi Kokusai Electric

Hitachi Kokusai Electric SK-HD1200 operating instructions

Channel Vision 6404 Instructions for use

Channel Vision

Channel Vision 6404 Instructions for use

Rausch minCam Operation manual

Rausch

Rausch minCam Operation manual

Retina RET1032 user manual

Retina

Retina RET1032 user manual

Intellisystem IT-VCHD1600JSE user manual

Intellisystem

Intellisystem IT-VCHD1600JSE user manual

Hitachi HV-F31CL Operation manual

Hitachi

Hitachi HV-F31CL Operation manual

VIDCOM KIR-R639D40 user guide

VIDCOM

VIDCOM KIR-R639D40 user guide

Sony HDC5500 operating instructions

Sony

Sony HDC5500 operating instructions

Sony KDP-673SH20 quick start guide

Sony

Sony KDP-673SH20 quick start guide

Zte MF68 user manual

Zte

Zte MF68 user manual

Ikegami ISD-A20 instruction manual

Ikegami

Ikegami ISD-A20 instruction manual

Basler Vision Technologies Sprint user manual

Basler Vision Technologies

Basler Vision Technologies Sprint user manual

FLIR Ax5 series user manual

FLIR

FLIR Ax5 series user manual

MISUMI CCIQ II MP-CB300T quick start guide

MISUMI

MISUMI CCIQ II MP-CB300T quick start guide

INTELART I3-C202 user manual

INTELART

INTELART I3-C202 user manual

Sony FCBEH6300 Technical manual

Sony

Sony FCBEH6300 Technical manual

WOOSHIN WS-50C owner's manual

WOOSHIN

WOOSHIN WS-50C owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1/3'' DOUBLE SCAN CCD
HIGH RESOLUTION
WDR Super High Resolution
Day & Night Color Camera
- ii -
WARNINGS:
CAUTION:
CAUTIONCAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER(OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in the
literature accompanying the product.
Should any liquid or solid object fall into the cabinet,
unplug the unit and have it checked by the qualified
personnel before operating it any further.
Unplug the unit from the wall oulet if it is not going to
be used for several days or more. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
Allow adequate air circulation to prevent internal heat
build-up. Do not place the unit on surfaces (rugs,
blankets, etc.) or near materials(curtains, draperies)
that may block the ventilation holes.
Height and vertical linearity controls located at the
rear panel are for special adjustments by qualified
personnel only.
Do not install the unit in an extremely hot or
humid place or in a place subject to excessive
dust, mechanical vibration.
The unit is not designed to be waterproof.
Exposure to rain or water may damage the unit.
Clean the unit with a slightly damp soft cloth.
Use a mild household detergent. Never use
strong solvents such as thinner or benzine as
they might damage the finish of the unit.
Retain the original carton and packing
materials for safe transport of this unit in the
future.
Safety ----------------------------------------- Installation -----------------------------------
Cleaning --------------------------------------
PRECAUTIONS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR
MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR
OTHER OPENINGS ON THE EQUIPMENT.
- iii -
FCC INFORMATION : THIS EQUIPMENT HAS BEEN TESTED
AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL
DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE
LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION
AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS
OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT
GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY
ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH
THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE
TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN
A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL
INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO
CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
CAUTION : CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE
COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN
ICES-003.
NORME NMB-003 DU CANADA.
WARNING
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE
THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.
CE COMPLIANCE STATEMENT
FCC COMPLIANCE STATEMENT
- iv -
IMPORTANT SAFEGUARDS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers) that
product heat..
9. Do not defeat the safety purpose of the polarized or grounding-type
Plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point where
exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this apparatus during lightning storms or when unused for
long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such
as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
14. CAUTION - THESE SERVICING INSTRUCTIONS ARE FOR USE
BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE
RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING
OTHER THAN THAT CONTAINED IN THE OPERATING
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
15. Use Certified/Listed Class 2 power source only.
thy
INTRODUCTION 1
CONTENTS OF PACKAGE 1
CAMERA CONNECTIONS 2
WALL BRACKET MOUNTING 2
CAMERA OVERVIEW 3
STRUCTURE OF THE SETUP MENU 4
CONTROL AND CONNECTIONS/DAY&NIGHT I/O/
ALARM OUT TERMINALS 8
WIRING DIAGRAM 9
HOUSING KIT SPECIFICATIONS 10
CAMERA SPECIFICATIONS 11
CAMERA ADJUSTMENT 3
- v -
TABLE OF CONTENTS
- 1 -
The camera provides high-quality images using SONY Wide Dynamic 1/3" CCD and digital
signal processing LSIs.
Features:
1/3" Super HAD Double Scan CCD for an image of high sensitivity
Wide Dynamic Range(WDR)
Excellent picture quality
600 lines(Color), 700 lines(B/W) of resolution
0.5 Lux(Color), 0.04 Lux(B/W), 0.001Lux(Low-shutter)@ F1.2 Sensitivity
Auto electronic shutter [1/60(1/50) ~ 1/100,000] and manual electronic shutter modes
OSD (On Screen Display)
Auto and manual white balance modes
Selectable BLC Zone
Day&Night (Auto/Manual, FILTER DLY)
Privacy Zone 16point, Motion Detection 4 Point
SHARPNESS, D-ZOOM, NEGA/POSI, MIRROR, V FLIP, ROTATION, FREEZE
AGC (Auto Gain Control)
RS485 CONTROL
Internal/AC line lock
Built-in 5-60mm or 2.8-12mm Vari-focal DC iris Lens.
Operates in 12VDC or 24VAC
Use Certified / Listed Class 2 power source only.
INTRODUCTION
IMPORTANT : The user of this camera is responsible for
checking and complying with local, state, and federal laws
and statutes concerning the recording and monitoring of
audio signals.
Installation of the camera must be performed by qualified service personnel in accordance
with all local and national electrical and mechanical codes.
Carefully remove the color camera and its accessories from the carton
and verify that they were not damaged in shipment.
The contents of the package includes:
1. CAMERA HOUSING KIT
2. This manual
3. L-wrench (5mm) --------------- 1ea
(2.5mm) ------------- 1ea
4. ANCHOR (5mm) --------------- 4ea
CONTENTS OF PACKAGE
- 2 -
CAMERA CONNECTIONS
2
1
REMINDER:
Never aim the
camera directly
into the sun.
1. Color Lead Wire & Color Display Label
2. Video : BNC connector used to connect the camera to a monitor, switcher, etc.
COLOR
BLACK
RED
BLUE
BROWN
DESCRIPTION
AC24V
AC24V
RS485(-)
RS485(+)
COLOR
BLACK
WHITE
ORANGE
BROWN
DESCRIPTION
DC12V
DC12V
RS485(-)
RS485(+)
1. Use fasteners of appropriate size and type to attach the bracket to the wall surface.
Position the housing so that it allow for viewing of the selected area.
2. Adjust the movable arm of the wall bracket to attain the desired position. One it is in place,
tighten the bolt located at the pivot point of the movable arm.
3. If you want to pull out the relevant cable, remove the knockout on the wall bracket mounting.
1
2
3
WALL BRACKET MOUNTING
- 3 -
CAMERA
CAM 001
Camera title.
Status of the dc level.
Camera ID.
CAMERA ADJUSTMENT
OSD MAIN SCREEN
DC LEVEL
CAMERA OVERVIEW
REAR VIEW
1
2
3
4
5
6
7
Left Button
Up Button
Enter Button
Right Button
Down Button
Day / Night External I/O
ALARM OUT
RS - 485
Power Indicator
Video Out Connector (BNC)
8
9
UTP or BNC Transformation Switch
(option)
Terminal
Block
1
23 4
5
6
7
10 8
9
10 AC/DC Compatible Input Terminal
STRUCTURE OF THE SETUP MENU
<MAIN MENU>
WB
AE
BLC / WDR
MOTION DET
PRIVACY
SPECIAL
EFFECT
CAM SET
END EXIT
<WB MENU>
MODE
R GAIN
B GAIN
END
<AE MENU>
LENS
MODE
SHUTTER
AGC
DC LEVEL, VIDEO LEVEL
(BRIGHTNESS)
FLICKERLESS
LOW SHUTTER
MAX LOW-SHUT
END
< WDR MENU>BLC/
END
BLC MODE
WDR MODE
L- LEVEL
S-LEVEL
<MOTION DET MENU>
AREA SEL
FUNCTION
DEFAULT
ADJ TOP / LEFT
ADJ BOT / RIGHT
SENSITIVITY
END
<PRIVACY MENU>
MASK SEL
MASKING
DEFAULT
ADJ TOP / LEFT
ADJ BOT / RIGHT
M COLOR
END
<SPECIAL MENU>
SYNC
PHASE
DN MODE
DN DELAY
END
<EFFECT MENU>
SHARPNESS
D-ZOOM
NEGA / POSI
D EFFECT
FREEZE
END
<CAM SET MENU>
CAM ID
BPS
PROTOCOL
DISP MODE
DISP ITEM
TITLE
SAVE
END
- 4 -
- 5 -
<WB>
Press the MENU button to access the "WB" mode.
1) MODE
Gain manually.
2) R GAIN A R-GAIN value.(0~255)
Can be adjusted while in manual mode.
O O
- AWB Set the color temperature 2500 K to 9500 K
- WAWB Wide range auto white balance mode.
O
- INDOOR Set the color temperature to 3200 K
O
- OUTDOOR Set the color temperature to 6300 K
- MANUAL Manual mode. User can change R and B
djust
3) B GAIN Adjust B-GAIN value.(0~255)
Can be adjusted while in manual mode.
<AE>
1) LENS
2) MODE
- AUTO Auto Exposure mode.
- SHUTTER Manual Shutter mode.
DC, Video, Manual Lens selected.
3) SHUTTER Select the shutter mode.(1/60(50) ~ 1/100,000 sec)
Can be changed while in shutter mode.
4) AGC Auto gain control ON/OFF
5) DC LEVEL / BRIGHTNESS
- DC LEVEL Adjust DC level (0 ~ 255)
Can be adjusted while in dc lens mode.
- VIDEO LEVEL Adjust VIDEO level (0 ~ 255)
Can be adjusted while in video lens mode.
- BRIGHTNESS Adjust BRIGHTNESS level (0 ~ 255)
Can be adjusted while in manual lens mode.
6) FLICKERLESS Removes screen flickering caused by discordance of
freguency and lighting.
7) LOW SHUTTER Use under very low light condition for full color surveillance.
8) MAX LOW-SHUT Select maximum Low-Shutter value. (x2 ~ x256)
Press the MENU button to access the "AE” mode.
< WDR>BLC/
Press the MENU button to access the " WDR" mode.BLC/
1) BLC MODE Sharpens subjects with backlight.
(OFF / CENTER / LEFT )TOP / BOTTOM / RIGHT /
2) WDR MODE Wide dynamic range ON/OFF
L- LEVEL Can be adjust long-time WDR level (0~200)
S- LEVEL Can be adjust short-time WDR level (0~200)