DESCRIPTION
The 424RG/434RG Optical Network Terminal (ONT) Fiber Tray
and Wall Mount Bracket (ONT Fiber Tray and Bracket) is used to
mount either of the following ONTs to a wall:
■ADTRAN 424RG 2 POTS/4 GigE Dual Band WiFi ONT
(P/N 1287781F1)
■ADTRAN 434RG 2 POTS/4 GigE RF MoCA Dual Band WiFi
ONT (P/N 1287782F1)
Required Tools
The following tools are required when installing the ONT Fiber
Tray and Bracket.
■Power drill (optional)
■Carpenter’s level (optional)
■Phillips-head Screwdriver
■Hammer
Installation Steps
To install the ONT Fiber Tray and Bracket, complete the following
steps:
1. Select Location and Mount Bracket.
2. Attach Incoming Fiber Cable to Bracket.
3. Remove Base (if required) from ONT.
4. Remove Logo Panel from ONT.
5. Connect Incoming Fiber Cable to ONT.
6. Attach ONT to ONT Fiber Tray and Bracket.
Step 1: Select Location and Mount Bracket
Select a location to mount the ONT Fiber Tray and Bracket near
the fiber entrance. Use the supplied hardware to mount the
bracket to the wall as follows:
Supplied hardware is intended for drywall mounting only. For
mounting on surfaces other than drywall, obtain the appropriate
mounting hardware and follow the provided instructions.
1. Refer to Figure 1 and mark hole locations using the ONT
Fiber Tray and Bracket as a template. Use a carpenter’s
level to ensure the bracket is level.
2. Start anchor into the wall by using a hammer to lightly tap
the anchor in until the threads are close to the wall.
gNOTE
Pre-drill holes using a 1/4” drill bit if difficulty is encountered.
3. Insert either a No. 2 or No. 3 Phillips driver bit into the recess
of the anchor head.
4. Using gentle forward pressure, rotate the wall anchor
clockwise until the collar is flush with the wall.
5. Align the ONT Fiber Tray and Bracket with the anchors.
Insert and tighten the #6 screws until the bracket is secured
to the wall.
Figure 1. Select Location and Mount Bracket
Step 2. Attach Incoming Fiber Cable to Bracket
Refer to Figure 2 and wrap any excess incoming fiber around the
ONT Fiber Tray and Bracket.
Do not exceed a minimum bend radius of 2-inches when installing
fiber cabling.
Figure 2. Attach Incoming Fiber Cable to Bracket
Incoming
Fiber
Incoming
Fiber
ADTRAN ONT
424RG/434RG
Fiber Tray and Wall Mount Bracket
January 2018
61287412F1-13A
P/N: 1287412F1
2 61287412F1-13A
Figure 5. Connect Incoming Fiber Cable to ONT
Step 6: Attach ONT to ONT Fiber Tray and Bracket
1. Refer to Figure 5 and position the ONT Mounting Sots so
that these align with the Mounting Bracket Tabs on the ONT.
2. Refer to Figure 6 and position the ONT so that the two
mounting tabs on the top of the ONT Fiber Tray and Bracket
align with the mounting slots in the back of the ONT.
3. Refer to Figure 6 and gently push the ONT towards the ONT
Fiber Tray and Bracket until the ONT snap onto the bracket.
Figure 6. Attach ONT to ONT Fiber Tray and Bracket
Mounting
Bracket Tabs
ONT
Mounting Slots
Step 3. Remove Base (if required) from ONT
Refer to Figure 3 and remove the screw that holds the base to the
bottom of the ONT.
After the base has been removed, reinsert the screw into the
bottom of the ONT and tighten.
Figure 3. Remove Base from ONT
Step 4. Remove Logo Panel from ONT
Refer to Figure 4 and remove the Logo Panel from the ONT by
pulling it straight out from the ONT housing.
Figure 4. Remove Logo Panel from ONT
Step 5. Connect Incoming Fiber Cable to ONT
Refer to Figure 5 and connect the Incoming Fiber Cable to the
Fiber Connector on the bottom of the ONT.
Screw
Logo
Panel
61287412F1-13A 3
Once all cables have been reconnected, refer to the LED table
below to ensure the ONT is operating properly.
424RG and 434RG LEDs
“*” This indicates the use of the feature is dependant upon provisioning by network
personnel.
“**” This option is only available on the 434RG ONT.
Label Status Indication
POWER 

Off
Green
AC or battery off
No Failure
FIBER 

2
Off
Green
Green Flashing
Fast
No connection to the OLT,
open fiber, failure at the ONT,
or power is Off
DS signal present and is within
operating range
Ranging in Progress or AOE
Auto-upgrade in progress
INTERNET 

Off
Green
No IP address configured on
WAN Interface, or Power is Off
WAN Interface is configured
with IP address
GE 1-4 

2
Off
Green
Green Flashing
Fast
Link is down or not connected
Link is up
Data is being sent or received
USB 

2
Off
Green
Green Flashing
Fast
Power Off or no device
connected
Device connected
Data is being sent or received
2.4GHZ* 

2
Off
Green
Green Flashing
Fast
Power is Off, or Wireless
2.4GHz is Disabled
Wireless 2.4GHz is Enabled
Data is being sent or received
on 2.4GHz
5GHZ* 

2
Off
Green
Green Flashing
Fast
Power is Off, or Wireless 5GHz
is Disabled
Wireless 5GHz is Enabled
Data is being sent or received
on 5GHz
PHONE 1-2 

2
Off
Green
Green Flashing
Slow
Unequipped or on-hook and
not ringing
Line is off-hook
Line in ringing state
RF+MOCA** 

2

Off
Green
Yellow Flashing
Red
No RF connection
RF-only connection
MoCA-only connection
RF+MoCA down
WPS* 

2
Off
Green
Green Flashing
Fast
Power Off or WPS is Disabled
WPS is Enabled
WPS push button pressed and
device is ready to accept
connection
Documentation for ADTRAN Network Solutions products is available for
viewing and download directly from the ADTRAN Support Community
website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including customized
training and courses taught at our facilities or at customer sites.
For inquiries, go to: http://adtran.com/training
The following online documents and resources provide additional information for this product:
ADTRAN 424RG 2 POTS/4 GigE Dual Band WiFi Residential Gateway ONT Job Aid
ADTRAN 434RG 2 POTS/4 GigE/RF MOCA Dual Band WiFi ONT Job Aid
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at www.adtran.com/warranty.
Trademarks: Brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
©2018 ADTRAN, Inc. All Rights Reserved.
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
ADTRAN CUSTOMER CARE:
From within the U.S. 1.888.423.8726
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61287412F1-13A*

Other manuals for 424RG

4

This manual suits for next models

1

Other ADTRAN Rack & Stand manuals

ADTRAN 424RG User manual

ADTRAN

ADTRAN 424RG User manual

ADTRAN 401 User manual

ADTRAN

ADTRAN 401 User manual

ADTRAN SDG CPE Wall Mount 1 User manual

ADTRAN

ADTRAN SDG CPE Wall Mount 1 User manual

ADTRAN DSU III DBU User manual

ADTRAN

ADTRAN DSU III DBU User manual

ADTRAN SDG CPE User manual

ADTRAN

ADTRAN SDG CPE User manual

ADTRAN BR1/10 Maintenance and service guide

ADTRAN

ADTRAN BR1/10 Maintenance and service guide

ADTRAN 414 RG User manual

ADTRAN

ADTRAN 414 RG User manual

Popular Rack & Stand manuals by other brands

HAGOR Mobile Lift Pro Light installation manual

HAGOR

HAGOR Mobile Lift Pro Light installation manual

Honey Can Do GAR-01304 manual

Honey Can Do

Honey Can Do GAR-01304 manual

StarTech.com ARMPIVOT2USB3 user manual

StarTech.com

StarTech.com ARMPIVOT2USB3 user manual

Farnell PS-UTTS32B manual

Farnell

Farnell PS-UTTS32B manual

peerless-AV CM50 Installation and assembly

peerless-AV

peerless-AV CM50 Installation and assembly

HMS KLT21 Manual instruction

HMS

HMS KLT21 Manual instruction

Nordic DELTACO ARM-0450 user manual

Nordic

Nordic DELTACO ARM-0450 user manual

CHIEF Ceiling Plate CMA-330 installation instructions

CHIEF

CHIEF Ceiling Plate CMA-330 installation instructions

knapp easy-con Series Construction manual

knapp

knapp easy-con Series Construction manual

Klus 3035-KOZE Mounting instructions

Klus

Klus 3035-KOZE Mounting instructions

peerless-AV PLA50 Installation and assembly

peerless-AV

peerless-AV PLA50 Installation and assembly

Vivo STAND-V003E instruction manual

Vivo

Vivo STAND-V003E instruction manual

Bogen Horn Speaker Electrical Box Mounting Strap... product manual

Bogen

Bogen Horn Speaker Electrical Box Mounting Strap... product manual

Daktronics Sportsound SSR-200 Operation manual

Daktronics

Daktronics Sportsound SSR-200 Operation manual

RCA Universal MAF10 user manual

RCA

RCA Universal MAF10 user manual

Axis F8001 installation guide

Axis

Axis F8001 installation guide

Konig & Meyer 21320 INFORMATION FOR USE

Konig & Meyer

Konig & Meyer 21320 INFORMATION FOR USE

Vivo STAND-V003T/W instruction manual

Vivo

Vivo STAND-V003T/W instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.