manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aegis
  6. •
  7. Intercom System
  8. •
  9. Aegis 8250 User manual

Aegis 8250 User manual

TECHNICAL SUPPORT IS AVAILABLE MON-FRI
7:30AM-3:30PM PST AT 1-888-678-7224
by Pach & Co.Quick Guide
Parts above are only
included on complete
system (8250)
Missing Parts, contact Pach
and Company 1-888-678-
7224
Defective system under
manufacturer warranty,
call 1-888-678-7224 for
advance replacement
24 Months warranty for
complete system
6 Months warranty for
Printed Circuit Board
(8PCB250)
Manuals, management
software, catalog are on CD
or download at www.pach-
co.com
Red button is Master Code retrieval button. See also diagram.
What is Master Code: 4- digit code to log-on to programming mode
(0000 is default)
What is Dir (directory code): 2, 3, or 4 digit number see function
code 09. The number can be associated to apartment no., first three
digit of phone no., last four digit of phone no. , or any random no.
assigned to each tenants. Every tenant must have different directory
code no..
What is Access Code: 4-digit code for tenant to open the door or
gate.
Exit program, clear field,
reset keystroke. 17 Set system date
Save program 19 Initialize event recording
buffer
00 Change master code
(0000 is default) 20 Remote unlock relay 1
(1-9, 9 is default)
01 Add new tenant 21 Remote unlock relay 2
(1-9, 8 is default)
02 Edit existing tenant 40 Master code mask.
Warning: read manual
for more detail.
03 Delete existing tenant 46 Display system’s
information
04 Clear all tenants 50 Clear memory to factory
default
05
Manual unlock/lock relay 1
with timer (01-98 hours, 99
hours unlock hold, 00
hours to lock)
70 Select Modem Protocol
V22 or B212
06 Manual unlock/lock relay 2 71 Enable Disable Modem
07 Single or multi system
(single is default) 72 Invalid code lock-out
count (1-9). 3 is default
08 System ID number (n/a) 73 Tone/pulse dialing.
Tone is default
09 Directory digit (2, 3 or 4
digit, 3 digit is default) 74 Enable/disable auto
answer. Enable is
default
10 Edit scrolling message 75 Enable/disable keypad
press beep. Enable is
default
11 Relay 1 unlock interval
(04-99 seconds, 12
seconds is default) 76 Enable/disable speaker
beep. Enable is default
12 Relay 2 unlock interval 77 Enable/disable PBX.
Disable is default
14 Set system clock 78 View name and
directory
15 Day light saving 79 Talk time (10-180
seconds). 60 second is
default
16 Display current time 91 Total number of tenant.
Tenant with no name
will not be included
Log on to programming: Press
simultaneously then release, welcome
message will stop scrolling (repeat if screen
still scrolls) enter 4-digit “MASTER CODE”
(0000 is default), the screen will show:
Select the “Function Code” from the table
Two ways call from the system
1.Press to scroll name from A-Z or to scroll name from
Z-A then press to call name selected.
2.Press wait for dial tone then press the directory no.
Opening the door remotely press to release relay 1
(door 1) or to release relay 2 (door 2).
Opening the door using the access code press (display
screen will stop scrolling) then press a valid 4-digit access
code.
Extending talk time tenant must press from the phone
after the time out warning beep.
Calling into the system: incase you are not available when
your visitor call you. Follow steps below to use this feature
1.The system modem must be disabled and function 74 (auto
answer must be enabled).
2.Call the system’s phone no., you will hear “ONE BEEP”, then
press to talk to your visitor. Press or to release
the door
1. Press after selecting a letter or character.
2. You have 30 seconds to enter each letter or character.
3. Letter QZ, numeric 0-9 and punctuations press
4. Press space and for backspace
COMPLETE MANUALS ARE ON CD PROVIDED OR DOWN LOAD ON LINE AT www.pach-co.com
1
2
3
4
5
6
7
1. EARTH GROUND
16 gauge- single solid wire to
ground the system. If the
system has been struck by
lightning multiple times, try to
remove the earth ground.
2. TELEPHONE LINE
Cat 5 twisted pair (from the
telephone company dial
tone), maximum distance 200
feet. If you encounter static or
radio interference:
Remove the earth ground
Install a DSL filter in series
with the phone line.
Install RF filter
Contact the radio station,
they may have a solution
3. DOOR STRIKE/GATE
The system has two
independent on board relays
(125VAC 12A, 250VAC 7A,
and 30VDC 7A). 18 gauge 2-
conductors stranded wire for
each door. An isolation relay
with separate power supply is
recommended for magnetic-
lock. Installation to eliminate
spikes. See diagram for
wiring connections, also refer
to door strike or gate operator
owner’s manual.
4. POSTAL LOC
K
Postal switch blue and yellow wires
are connected to the terminal pins
POST and LCOM
Postal input only works for relay 1.
Postal switch and knock-out are
provided. Call the local post office
for installing the postal lock
POST and LCOM input can also
be used for free exit switch, loop
detector or any device with dry
contact output.
5. POWER
12Vac 40VA supplied or 12Vdc
3A not supplied. Use at least 18
gauge 2 conductors stranded
wires for power. The voltage
measurement must be in the
range of :
12.5Vac-14Vac--12Vac power
13.5Vdc-14Vdc-- 12Vdc power
Warning: If you have low voltage
issue, do not use higher voltage
transformer or power supply, to do
so will damage the system.
Install surge protector (ASP1) or UPS
for power and telephone to protect the
system from power surges.
6. BATTERY BACKUP
Optional battery backup is
needed to keep the system
in operational during the
power outages. Use
ABAT1 (12Vdc 4.5Ahr, last
for 3-4 hours). Use 18
g
au
g
e 2 conductors
7. NIGHT LIGHTS
The night lights turn on
24/7, prewired to +12V and
LCOM.
Warning: DO NOT USE
+12V and LCOM terminal
pins for input power.
8. KEYPAD AND LCD RIBBON
CABLE
Ribbon cables must be plugged in
as shown on diagram with the red
line dots are on top.
8

Prior removing the knock-out, any
drilling or grinding during the
installation removes the board.
Always turn the system off if you are
doing service.
Place ribbon cables on the side before
closin
g
the
p
anel’s door.

This manual suits for next models

1

Popular Intercom System manuals by other brands

Schaefer FPM 32 installation instructions

Schaefer

Schaefer FPM 32 installation instructions

Aiphone AN-8000EX installation manual

Aiphone

Aiphone AN-8000EX installation manual

SSS Siedle ZS 932-0S user manual

SSS Siedle

SSS Siedle ZS 932-0S user manual

BEC B-WSP1 User's setup guide

BEC

BEC B-WSP1 User's setup guide

Toa IC-100 Series supplementary guide

Toa

Toa IC-100 Series supplementary guide

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

Fermax VDS Advanced Programming

Fermax

Fermax VDS Advanced Programming

Dahua Villa DHI-VTO2101E-P-S2 user manual

Dahua

Dahua Villa DHI-VTO2101E-P-S2 user manual

PEAKnx Doorbird Connect Getting started

PEAKnx

PEAKnx Doorbird Connect Getting started

SECO-LARM SD-998C-NUQ manual

SECO-LARM

SECO-LARM SD-998C-NUQ manual

LAON TECHNOLOGY LT550 EXPERT operating instructions

LAON TECHNOLOGY

LAON TECHNOLOGY LT550 EXPERT operating instructions

Lutron Electronics QS Wallstation Signature Series installation guide

Lutron Electronics

Lutron Electronics QS Wallstation Signature Series installation guide

Vimar ELVOX 7559 manual

Vimar

Vimar ELVOX 7559 manual

Alphatech IP-VarioBell IPVB-01 Installation and operating instructions

Alphatech

Alphatech IP-VarioBell IPVB-01 Installation and operating instructions

SSS Siedle DCA 650-02 Programming instructions

SSS Siedle

SSS Siedle DCA 650-02 Programming instructions

Alula CAM-DB-H2S-AI Quick setup

Alula

Alula CAM-DB-H2S-AI Quick setup

Videx ESVK 6388 Series Installation handbook

Videx

Videx ESVK 6388 Series Installation handbook

Bpt DVC/01 instructions

Bpt

Bpt DVC/01 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.