This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
Hardware
BEFORE beginningthe update process, be sure to have a savedcopy of your tunedsession file (if
needed). If a power failure occurs during the update process, this is the only way to ensure that the
calibration data is not lost. A power failure at certain critical points in this process could render the ECU
inoperative, requiring return and repair at AEM. Ensure the PC has a full battery charge and/or is
connected to AC power. This process can take UP TO 4 MINUTES to complete, especially if the peripheral
microcontroller is updated at the same time.
If the firmware version on the ECU is older than the version supportedby your current version of Infinity
Tuner, a firmware upgrade will be required when you connect. Otherwise, follow the procedure outlined
below.
Note: The firmware update utility is periodically revised and may not match the descriptions below. In the
event of a conflict, please follow the instructions provided in the dialog windows themselves or
supplemental instructions provided by AEM.
1) Connect to Infinity Tuner.
a. Plug the USB cable from the ECU into your computer USB port and key ignition ON.
b. Open Infinity Tuner.
2) Click the ECUdrop-down list and select “Upgrade firmware…”
3) The ECU should not be running an engine at this time. Select “Yes” when the warning message appears.
Begin the Firmware Upgrade process.
a. Select the desired Configuration “Image” on the left.

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
i. If no images are present check C:\Program Files (x86)\AEM\Infinity Tuner\ and verify .pakgrp file is
there. If not, visit http://www.aeminfinity.com, log in, and download appropriate file.
b. Ensure "Keep Calibration Data" check-boxis marked to save current calibration.
c. Click the “Begin” button to start the upgrade process.
4) Followthe message at the bottom, and turn the ignition switch OFF when instructed to do so.

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
5) Followthe message at the bottom, and turn the ignition switch back ON when instructed to do so.
If Keep Calibration Data is checked, the system will upgrade and load all usable calibration data as shown below.

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
Note: at certain points in the process, the Infinity ECU will re-boot and attempt to connect with the PC. The
time it takes to connect might vary for different PCs. If the process appears to hang at this stage, simply
unplug and replug the USB comms connector. Often this will force the PC to re-enumerate the USB port
and connect.

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
6. When the "Peripheral Control Module image" is updated, a full power reset may be required meaning either
the battery needs to be disconnected and re-connected or all harness connectors need to be removed from
the ECU for at least 5 seconds, then re-connected.
7. When the message belowis displayed, turn the ignition switch back on.

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
8. When the message at the bottom indicates that it’s safe to close the window, click "X” button on the top right of
the window.
Once the update is complete, it's good practice to cycle the ignition switch to reset the hardware. Once that is
done, you can connect and begin monitoring data and/or tuning again. For applications that use a stepper
motor idle valve, it's important that a full power reset be done prior to starting the engine. Turn the key
off and wait at least 20 seconds before starting. This will allow the stepper valve to park and reset.
A firmware update will erase the USB log channel list stored in the ECU memory. This channel list will
need to be reset before USB logging will function correctly. Go to Logging>USB Logging – Channel
Setup. This dialog allows the user to select channels for USB logging. Manually select channels by left clicking

Instruction
Manual 30-71XX
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
Document FirmwareUpdate
on the check boxor alternately by using the arrowkeys to scroll through the list and the space bar key to select.
Logging lists can be saved for later use by using the Save button. The Load button will load previously saved lists
of channels. The Append button will append a different list of channels onto the existing list of selected channels.
Note that the list of channels for logging is saved in ECU memory. Channels can't be selected offline. They can
only be selected when connected to an ECU.
Table of contents
Other AEM Control Unit manuals
Popular Control Unit manuals by other brands

Robertshaw
Robertshaw Uni-Kit 780-001 Installation data

Beehive International
Beehive International DM3270 Technical user's manual

pizzato
pizzato CS MP312-0 quick start guide

National Instruments
National Instruments NI 9218 Getting started guide

Woodward
Woodward easYgen-1000 Applications manual

Keba
Keba D3DP 3 Series Project engineering manual